Surge arrester
3-electrode arrester
Series/Type:
Ordering code:
Date:
Version:
T23-A260XF1
B88069X4871B502
2016-03-14
02
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
Surge arrester
(header 1 + top left bar):
Identification/Classification 2
3-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar)
B88069X4871B502
Series/Type: (bottom right header bar)
T23-A260XF1
Preliminary data (optional):
Department:
PPD AB PD / PPD AB PM
Date:
2016-03-14
Version:
02
EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester
3-electrode arrester
B88069X4871B502
T23-A260XF1
Features
Standard size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
Reliable failsafe device
RoHS-compatible
Applications
Base stations
Line protection
Station protection
Electrical specifications
DC spark-over voltage
1) 2) 3)
Tolerance
Min.
Max.
Impulse spark-over voltage
3)
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs
- for 99% of measured values
- typical values of distribution
Service life
10 operations
1 operation
10 operations
[5× (+) & 5× (–)]
1 operation
1 operation
300 operations
[150× (+) & 150× (–)]
Insulation resistance at 100 V
DC 3)
Capacitance at 1 MHz
3)
Transverse delay time
5)
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Storage temperature
Climatic category (IEC 60068-1)
Marking, blue negative
260 YY O
260
YY
O
- Nominal voltage
- Year of production
- Non radioactive
260
20
208
312
< 500
< 400
< 600
< 550
10
50
20
25
5
200
> 10
< 1.5
< 0.2
~ 35
<1
~ 200
~2
40
... +90
40/090/21
V
%
V
V
V
V
V
V
A
A
kA
kA
kA
A
G
pF
µs
V
A
V
g
°C
50 Hz; 1 s
4)
50 Hz; 0.18 s (9 cycl.)
4)
8/20 µs
4)
8/20 µs
4)
10/350 µs
4)
10/1000 µs
4)
Certifications
Remarks on next page
UL 497B (E163070)
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 6
2016-03-14
Surge arrester
3-electrode arrester
B88069X4871B502
T23-A260XF1
1)
2)
3)
4)
5)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Tip or ring electrode to center electrode
Total current through center electrode, half value through tip respectively ring electrode.
Test according to ITU-T Rec. K.12
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
The arrester failsafe mechanism contains a solder pellet with a melting temperature between 193 and 203 °C.
Failsafe characteristic diagram
For arrester only, characteristic can differ in assembled module.
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 6
2016-03-14
Surge arrester
3-electrode arrester
B88069X4871B502
T23-A260XF1
Dimensional drawing in mm
Ordering code and packing advice
B88069X4871B502 = 500 pcs. on trays
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 6
2016-03-14
Surge arrester
3-electrode arrester
B88069X4871B502
T23-A260XF1
Soldering parameter
Wave soldering
Wave profile features
Solder
Solder bath temperature
Dwell time
Pb-free assembly
Sn 95.5 / Ag 3.8 / Cu 0.7
263 (±3) °C
<3s
Soldering profile applied to a single soldering process.
Cautions and warnings
Depending on the sensor material the short-circuit spring does not trigger until 180 °C is reached.
Thermal radiation to adjacent components must be taken into consideration in the circuit design.
Depending on the mounting position, the surge arrester may have to be secured by additional
mechanical means.
Do not continue to use surge arresters whose short-circuit mechanisms have been activated.
If the contacts of the surge arresters are defective, current load can cause sparks and loud
noises.
Do not operate surge arresters in power supply networks, whose maximum operating voltage
exceeds the minimum spark-over voltage of the surge arresters.
Surge arresters may become hot in the event of longer periods of current stress (burn risk). In the
event of overload the connectors may fail or the component may be destroyed.
Surge arresters must be handled with care and must not be dropped.
Do not continue to use damaged surge arresters.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data
sheets, data books, other publications, on the EPCOS website, or in order-related documents such as
shipping notes, order confirmations and product labels.
The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of
the respective products.
Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 6
2016-03-14