1500 HN series
Dual Output
DC/DC Converter
F
EATURES
•
•
•
•
•
www.martekpower.com
Up to 85% Efficiency
Dual Output, Up To 15 watt converter
Available in 12, 24 and 48 VDC Inputs
Industry Standard 1.0” X 2.0” X 0.375” Package
Remote On/Off, Input Over Voltage and Short Circuit
Protection
I
NPUT
C
HARACTERISTICS
D
ESCRIPTIONS
The 1500HN, dual output power modules are 15 watt DC/DC
converters available in a dual output configuration provid-
ing both digital and analog outputs in a compact, industry
standard 1.0" X 2.0" X 0.375" package. These 400kHz, switch-
ing converters are available in 12, 24 and 48 VDC inputs
making them one of the most versatile product lines in the
market with efficiencies up to 85%. Advanced surface
mount construction allows these converters to achieve
outstanding thermal performance eliminating the need for
thermal potting compounds and thereby enhancing manu-
facturing efficiency to reduce costs.
Min Typ Max Units/Comments
Input Voltage
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Under Voltage Shut Down
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Minimum Input Current
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Full Load Input Current
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Input Fuse Requirements
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Efficiency by Model
1505D12HN
1512D12HN
1515D12HN
1505D24HN
1512D24HN
1515D24HN
1505D48HN
1512D48HN
1515D48HN
Switching Frequency
Remote Shut Down Off
On
9
18
36
7
15
28
0
0
0
1.60
0.77
0.38
4
3
2
80
82
82
83
84
84
84
85
85
360 400 440
0
0.80
3.5
12
24
48
18
36
75
VDC
VDC
VDC
VDC
VDC
VDC
mA
mA
mA
A
A
A
Amps; Slow blow type
Amps; Slow blow type
Amps; Slow blow type
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
%; FL Nominal Line
kHz; Factory set
VDC;Referenced to input
VDC or open ;
Referenced to input
pF
LC type
VDC
MOhms
O
UTPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Set Point
% Output voltage at
±1
nominal line & FL
Total Band Error
-3
+3 % Output voltage
including line/load
regulation setting
Temperature Coefficient
% per degree C
±0.01
Ripple/Noise
60 100 mV p-p measured
at 20 MHz bandwidth
with external 1
μf
capacitor
Output Voltage and Current
Refer to model
selection chart
Load Transient Response
% deviation of Vout
±2
voltage for a 25%
load change for
200μS
Short Circuit Protection
Indefinite, Automatic
Recovery
Output Voltage Trim Range
% Output voltage.
±10
Place ext. resistor
between pins 9 - 6 to
trim down. Between
pins 9 - 5 to trim up
Overvoltage Protection
%; Clamp type
260
Input - Output Capacitance
1200
Input Filter
Isolation Voltage
1500
Isolation Resistance
100
Martek Power reserves the right to change specifications without notice.
B-114
M
ODEL
S
ELECTION
C
HART
Input Voltage
Output
(VDC)
Voltage (VDC)
1505D12HN
1512D12HN
1515D12HN
1505D24HN
1512D24HN
1515D24HN
1505D48HN
1512D48HN
1515D48HN
12
12
12
24
24
24
48
48
48
±5
±12
±15
±5
±12
±15
±5
±12
±15
Full Load
Output
Current (A)
±1.500
±0.625
±0.500
±1.500
±0.625
±0.500
±1.500
±0.625
±0.500
G
ENERAL
C
HARACTERISTICS
Operating Temp. Range
Storage Temp. Range
Material Flammability
Altitude: Operating
Non-Operating
Relative Humidity
Weight
Size
Case Material
Agency Approvals
Min
-40
-55
Typ
Max Unit/Comments
+105 °C; measured
at baseplate
+125 °C; measured
at baseplate
UL94V-0
10,000 Feet
40,000 Feet
95 % Humidity,
non-condensing
22 Grams
1.0” X 2.0” X 0.375”
Black coated
aluminum
UL/CUL1950,
TUV, EN60950
5
O
UTLINE
D
RAWING
0.400
(10.16)
.125 (3.18)
0.400
(10.16)
0.10 (2.5) TYP.
3
4
1 2
5
6
0.800 TYP.
(20.32)
2.00
(50.8)
0.040 ±.002
(1.02 ±0.05)
PIN DIA. TYP.
0.60
(15.2)
0.020 (0.51)
0.375 (9.53)
0.400
(10.16)
0.200
(5.08)
1.00
(25.4)
0.300
(7.62)
SIDE VIEW
BOTTOM VIEW
P
IN
O
UT
C
HART
Pins
1
2
3
4
5
6
FUNCTION
+ Vin
- Vin
+ Vout
COMMON
- Vout
*REMOTE ON/OFF
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances
Inches
mm
X.XX = ±0.02
X.X = ±0.5
X.XXX= ±0.010
X.XX = ±0.25
2. Controlling dimension in inches.
3. Case is vented on 2” long sides only.
* Optional - present on -R Models only.
All specifications are typical at nominal input, nominal load and 25
°
C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across output is recommended for operation.
B-115
H
OW
T
O
O
RDER
H
OW TO
O
RDER
15 XX D XX HN - Y
ROHS Compliant
Wattage
Output Voltage
Hi-Density, Non-Encap
Dual Output
Input Voltage
R Options: To add the remote on/off feature to the converter please add a “-R” at the end
of the part number. An additional pin (pin#6) will be added to the converter. Consult
mechanical drawing for location.
D
ERATING
C
URVES
MODEL 1500HN Dual 3.3V & 5V
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
500LFM
200LFM
100LFM
Natural
Convection
0
10
20
30
40
50
60 70
80
90 100 110
TEMPERATURE
°
C
MODEL 1500HN Dual 12 & 15V
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
500LFM
200LFM
100LFM
Natural
Convection
0
10
20 30
40
50 60 70
80
90 100 110
TEMPERATURE
°
C