ER3A THRU ER3J
SURFACE MOUNT SUPERFAST RECOVERY RECTIFIER
REVERSE VOLTAGE:
FORWARD CURRENT:
FEATURES
· Plastic package has Underwriters Laboratory
Flammability Classification 94V-O
· For surface mounted applications
· Low profile package
· Easy pick and place
· Built-in strain relief
· Superfast recovery times for high efficiency
· High temperature soldering : 250°C /10 seconds at terminals
DO214-AB(SMC)
50 to 600 VOLTS
3.0 AMPERE
MECHANICAL DATA
Case: Molded plastic, DO-214AB(SMC)
Terminals: Solder plated, solderable per MIL-STD-750,
method 2026 guaranteed
Polarity: Color band denotes cathode end
Packaging: 16mm tape per EIA STD RS-481
Weight: 0.007 ounce, 0.21 gram
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Ratings at 25
℃
ambient temperature unless otherwise specified.
Single phase, half wave, 60H
Z
, resistive or inductive load.
For capacitive load, derate current by 20%.
Symbols
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T
L
=75℃
Peak Forward Surge Current,
8.3ms single half-sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage at 3.0A
Maximum Reverse Current
at Rated DC Blocking Voltage
at T
A
=25℃
T
A
=100℃
V
F
I
R
C
J
R
θJL
T
RR
T
J
Tstg
I
FSM
V
RRM
V
RMS
V
DC
I
(AV)
ER3A
ER3B
ER3C
ER3D
ER3E
ER3G
ER3J
Units
Volts
Volts
Volts
Amp
50
35
50
100
70
100
150
105
150
200
140
200
3.0
300
210
300
400
280
400
600
420
600
100
0.95
5.0
200
45
16
35
-55 to +150
-55 to +150
50
1.25
1.70
Amp
Volts
μAmp
pF
℃/W
nS
℃
℃
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 2)
Maximum Reverse Recovery Time (Note 3)
Operating Junction Temperature Range
Storage Temperature Range
NOTES:
1- Measured at 1 MH
Z
and applied reverse voltage of 4.0 VDC.
2- Thermal resistance from junction to lead mounted on P.C.B. with 0.3 x 0.3” (8.0 x 8.0mm) copper pad areas
3- Reverse Recovery Test Conditions:I
F
=.5A,I
R
=1A,I
RR
=.25A.