KILOVAC High Voltage Relays
K62 Series Make & Break Load Switching — 25 kV Relays
K62A and K62B
Product Facts
n
n
n
25 kV relay with flying leads
for ease of installation
Vacuum dielectric and
tungsten contacts for power
switching low current loads
Meets requirements of
MIL-R-83725
K62C
Product Facts
n
n
n
n
SPDT version of K62
Vacuum dielectric for power
switching low current loads
Carries 18 Amps continuous
current
Meets requirements of
MIL-R-83725
Product Specifications for
K62A, K62B and K62C
Contact Arrangement
—
K62A — SPST-NO
K62B — STST-NC
K62C — SPDT
Contact Form
—
K62A — A
K62B — B
K62C — C
Test Voltage, DC or 60 Hz (Peak)
—
30 kV
Rated Operating Voltage (Peak)
—
DC or 60 Hz — 25 kV
Continuous Carry Current, Max.
—
DC or 60 Hz — 18 A
Coil Hi-Pot (Vrms, 60 Hz) — 500 A
Contact Resistance, Max.
—
0.50 ohm
Operate Time, Max.
— 15 ms
Release Time, Max.
— 15 ms
Shock, 11ms, 1/2 Sine (Peak)
—
20 g
Vibration
—
Peak — 10 g (55 to 500 Hz)
Operating Ambient Temperature
Range
— -55°C to +85°C
Mechanical Life
— 1 million cycles
Weight, Nominal
— 340 g (12 oz.)
Coil Data
Volts, Nominal DC
Pickup, Max.
Dropout
Coil Resistance (±10%)
12 V
9 Vdc
.5-5 Vdc
30
Ω
26.5 V
18 Vdc
1-10 Vdc
125
Ω
115 V
90 Vdc
5-55 Vdc
2400
Ω
Ratings listed are for 25°C, sea level conditions
Ordering Information
Sample Part Number
K62 A 7 4 1
Series:
Contact Form:
A = SPST-NO
B = SPST-NC
C = SPDT
Coil Voltage:
7 = 12 Vdc, Turret Terminal
8 = 26.5 Vdc, Turret Terminal
9 = 115 Vdc, Turret Terminal
High Voltage Connections:
4 = Flying Leads, 12"
7 = Flying Leads, 72"
8 = Flying Leads, 36"
Mounting:
1 = Threaded
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
7–78
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject