• Industry standard design with switching currents of 10A to 21A
• Widely used for applications where long life expectancy and
high reliability is required.
• Choose from a variety of levers, terminals and operating forces.
• Right and Left Barrier options are available for the V-21 and
V-16 models
• Heat resistant versions of the V-15 and V-10 are available.
• RoHS Compliant
Ordering Information
■
Model Number Legend
V-
1 2 3
1.
-
4 5 6 7
-
8
-
9
4. Contact Form
COM Terminal, Bottom position:
1:
SPDT
2:
SPST-NC
3:
SPST-NO
COM Terminal, Side position:
4:
SPDT
5:
6:
5.
SPST-NC
SPST-NO
9.
7.
Maximum Operating Force
6:
400 gf
5:
200 gf
4:
100 gf
Note:
These OF
values
are for
the pin plunger models.
Ratings
21:
21 A at 250
VAC
16:
16 A at 250
VAC
15:
15 A at 250
VAC
11:
11 A at 250
VAC
10:
10 A at 250
VAC
Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
2.
8.
Special Purpose
None: Standard
T:
Heat resistive
(V-15 and
V-10,
only)
Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
3.
Terminals
A:
Solder terminals
C2:
Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
6. Insulation Barrier
None:
Without
Barrier
R:
Right-hand
barrier
L:
Left-hand
barrier
(Barriers available for
V-21
and
V-16,
only)
Note:
Consult Omron regarding nominclature combinations and part numbers
not found in this datasheet.
Snap Action Switch
V
121
■
Available Combinations
Thermoplastic case
Model
Rated Current
OF
COM
Heat
Insulation
terminal
Barrier Resistance Terminal Symbol
position
Bottom
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Heat
resistant
(150°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Yes
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Side
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Note: 1.
❍:
Available model.
Consult OMRON for specific models with standard approval.
V-21
21 A
400 gf
V-16
16 A
400 gf
200 gf
V-11
11 A
100 gf
Thermosetting case
V-15
15 A
400 gf
200 gf
V-10
10 A
200 gf
100 gf
---
---
❍
---
---
---
---
---
❍
---
---
❍
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
---
---
---
---
---
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
■
List of Models
Thermoplastic Case
21 A (OF: 400 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
Terminal style Actuator
Quick-connect
(#250) (C)
V-21-1C6
V-21-1CR6
V-21-2CR6
V-21-3CR6
V-211-1CR6
V-212-1CR6
V-213-1CR6
V-214-1CR6
V-215-1CR6
V-216-1CR6
V-21-1CL6
V-21-2CL6
V-21-3CL6
V-211-1CL6
V-212-1C6
V-213-1CL6
V-214-1CL6
V-215-1CL6
V-216-1CL6
V-21-2C6
V-21-3C6
V-211-1C6
V-212-1C6
V-213-1C6
V-214-1C6
V-215-1C6
V-216-1C6
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Example: V-21G2-1C6-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
122
Snap Action Switch
V
16 A (OF: 200 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
SPST-NC
SPST-NO
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-16-1A5
V-16-1C25
V-16-1C5
V-16-2A5
V-16-2C25
V-16-2C5
V-16-3A5
V-16-3C25
V-16-3C5
V-161-1A5
V-161-1C25
V-161-1C5
V-162-1A5
V-162-1C25
V-162-1C5
V-163-1A5
V-163-1C25
V-163-1C5
V-164-1A5
V-164-1C25
V-164-1C5
V-165-1A5
V-165-1C25
V-165-1C5
V-166-1A5
V-166-1C25
V-166-1C5
V-16-1AR5
V-16-1C2R5
---
V-16-2AR5
V-16-2C2R5
---
V-16-3AR5
V-16-3C2R5
---
V-161-1AR5
V-161-1C2R5
---
V-162-1AR5
V-162-1C2R5
---
V-163-1AR5
V-163-1C2R5
---
V-164-1AR5
V-164-1C2R5
---
V-165-1AR5
V-165-1C2R5
---
V-166-1AR5
V-166-1C2R5
---
V-16-1AL5
V-16-1C2L5
---
V-16-2AL5
V-16-2C2L5
---
V-16-3AL5
V-16-3C2L5
---
V-161-1AL5
V-161-1C2L5
---
V-162-1AL5
V-162-1C2L5
---
V-163-1AL5
V-163-1C2L5
---
V-164-1AL5
V-164-1C2L5
---
V-165-1AL5
V-165-1C2L5
---
V-166-1AL5
V-166-1C2L5
---
11 A (OF: 100 gf)
Without barrier
Common
terminal
position
Bottom
Contact form
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-11-1A4
V-11-1C24
V-11-1C4
V-111-1A4
V-111-1C24
V-111-1C4
V-112-1A4
V-112-1C24
V-112-1C4
V-113-1A4
V-113-1C24
V-113-1C4
V-114-1A4
V-114-1C24
V-114-1C4
V-115-1A4
V-115-1C24
V-115-1C4
V-116-1A4
V-116-1C24
V-116-1C4
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Examples: 1) V-16G3-1C25-K 2) V-11G-1A4-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Snap Action Switch
V
123
Thermosetting Case
Standard models - 15 A / 10 A
Common Contact
terminal
form
position
Bottom
SPDT
Terminal style
A
C2
C
A
C2
A
C2
C
A
Actuator
15 A
200 gf
200 gf
V-10G-1A5-K
V-10G-1C25-K
—
V-10G-2A5-K
V-10G-2C25-K
V-10G-3A5-K
V-10G-3C25-K
—
V-10G-4A5-K
V-10G-5A5-K
V-10G-6A5-K
V-10G1-1A5-K
V-10G1-1C25-K
V-10G2-1A5-K
V-10G2-1C25-K
V-10G3-1A5-K
V-10G3-1C25-K
V-10G4-1A5-K
V-10G4-1C25-K
V-10G5-1A5-K
V-10G5-1C25-K
V-10G6-1A5-K
—
V-15G-1A5-K
V-15G-1C25-K
V-15G-1C5-K
V-15G-2A5-K
V-15G-2C25-K
V-15G-3A5-K
V-15G-3C25-K
V-15G-3C5-K
V-15G-4A5-K
V-15G-5A5-K
V-15G-6A5-K
V-15G1-1A5-K
V-15G1-1C25-K
V-15G2-1A5-K
V-15G2-1C25-K
V-15G3-1A5-K
V-15G3-1C25-K
V-15G4-1A5-K
V-15G4-1C25-K
V-15G5-1A5-K
V-15G5-1C25-K
V-15G6-1A5-K
V-15G6-1C25-K
10 A
100 gf
V-10G-1A4-K
V-10G-1C24-K
—
V-10G-2A4-K
V-10G-2C24-K
V-10G-3A4-K
V-10G-3C24-K
—
V-10G-4A4-K
V-10G-5A4-K
V-10G-6A4-K
V-10G1-1A4-K
V-10G1-1C24-K
V-10G2-1A4-K
V-10G2-1C24-K
V-10G3-1A4-K
V-10G3-1C24-K
V-10G4-1A4-K
V-10G4-1C24-K
V-10G5-1A4-K
V-10G5-1C24-K
V-10G6-1A4-K
V-10G6-1C24-K
Pin plunger
SPST-NC
SPST-NO
Side
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
A
C2
A
C2
A
C2
A
C2
A
C2
A
C2
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
For SPST-NC and SPST-NO with levers consult Omron.
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Heat Resistant Models (Up to 150°C) - 15 A / 10A
Common
terminal
position
Bottom
Contact
form
SPDT
Terminal style
Solder Terminals
(A)
Actuator
15 A
200 gf
V-15-1A5-T
V-151-1A5-T
V-152-1A5-T
V-153-1A5-T
V-154-1A5-T
V-155-1A5-T
V-156-1A5-T
10 A
100 gf
V-10-1A4-T
V-101-1A4-T
V-102-1A4-T
V-103-1A4-T
V-104-1A4-T
V-105-1A4-T
V-106-1A4-T
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Add “C2” to the part number in the appropriate location to obtain versions with #187 quick-
connect terminals. Example: 1) V-15G1-1C25-T-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
124
Snap Action Switch
V
Specifications
■
Ratings
(reference values)
Type
Rated voltage
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
21 A
3A
21 A
5A
14 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
16 A
2A
16 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
15 A
2A
15 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
11 A
1.5 A
11 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
1.5 A
10 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
12 A
4A
12 A
7A
12 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
3A
6A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
V-21
V-16
V-15
V-11
V-10
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
Note: 1.
The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
values of models with a contact gap of 0.5 mm (gap G).
2.
Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
5.
The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
■
Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
V-21
21 A, 1/2 HP
V-16
16 A, 1/2 HP
V-15
15 A, 1/2 HP
0.6 A
0.3 A
V-11
11 A, 1/3 HP
V-10
10 A, 1/3 HP
EN 61058-1 (File No. 129608, VDE approval)
Rated voltage
250 VAC
V-21
20 (4) A
V-16
16 (4) A
V-11
11 (3) A
EN 61058-1 (File No. T9451451, TÜV Rheinland approval)
Rated voltage
250 VAC
250 VDC
V-15
15 A
0.3 A
V-10
10 A
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
Testing conditions: 5E4 (50,000 operations), T85 (0°C to
Serial communication is a very common communication method, with a small number of cables and simple operation. Let's take a look at the definition, principle and code implementation of serial communi...
[i=s]This post was last edited by btty038 on 2019-12-19 14:16[/i]Since the birth of the first radio transmitter, engineers have been concerned about RF power measurement, and it is still a hot topic t...
Project BackgroundSince the RISC-V architecture is an open source and free architecture, it has indeed attracted the attention and use of global manufacturers in recent years. Currently, there are mor...
Now the concepts of the Internet of Things and smart homes are gradually entering our daily lives. Various development platforms are becoming more and more convenient, and the graphical development me...
Unboxing
Mir's development boards all seem to come in a box.
The outer packaging is relatively large, and you can tell from the packaging that the board is not smallThe accessories are mainly power ad...
The waveform display speed is related not only to the waveform refresh rate of the oscilloscope itself, but also to the acquisition time and trigger settings. For example, the full screen of Agilen...[Details]
It’s almost a tradition for Microsoft to hold a Surface event in October, and even though everything has been postponed due to the pandemic, it won’t change this year. According to well-known leaker ...[Details]
The battery management system is an important system for electric vehicles, which is related to the safety of the battery. The electric vehicle battery management system (BMS) is an important link be...[Details]
1.W801 internal flash data 1.1 W801 internal flash usage partition The internal flash size of W801 is 2M bytes, and the physical address is 0x08000000-0x081FFFFF. In the CDK routines, each address se...[Details]
On May 24, TCL Huaxing’s official account showed that at the SID2022 exhibition, TCL Huaxing launched its first 17.3-inch 3K thin and light touch screen. Image source: TCL Huaxing It is reported th...[Details]
In the design of complex system-level microprocessors, the memory is responsible for storing system programs and data, and is an important part of the entire system. In the process of CPU executing...[Details]
Exception and interrupt handling, which is responsible for handling errors, interrupts, and other events triggered by external systems.
ARM has 7 exceptions: data abort, fast interrupt ...[Details]
With the rapid development of electronic technology, modern electronic equipment has been widely used in various fields of human life. At present, electronic equipment has been in a period of rapid...[Details]
ADLINK Technology, an industry leader in embedded computing products and Application Ready Intelligent Platforms, has introduced a number of products equipped with the latest Intel® AtomTM and Celero...[Details]
Minimizing the output ripple and transients of a switching regulator is important, especially when powering noise-sensitive devices such as high-resolution ADCs, where the output ripple will appear...[Details]
According to Jiwei.com, the Taiwan Meteorological Department recently released a weather forecast that is unfavorable to the water situation, estimating that the overall rainfall in spring (March to ...[Details]
When writing PLC programs, as long as you pay close attention to the content and quality, a program that is correct, reliable, convenient, concise and readable will be a good program!
1....[Details]
This 8½-digit Model 2002 high-performance digital multimeter not only provides performance specifications typically found only in instruments costing thousands of dollars, but it also has numerous fe...[Details]
On December 2, Qualcomm President Amon pointed out at the "2020 Snapdragon Technology Summit" that 5G commercialization began last year. It is expected that global 5G mobile phone shipments will reac...[Details]