EEWORLDEEWORLDEEWORLD

Part Number

Search

LPS-RK-80SP

Description
TIME DELAY BLOW ELECTRIC FUSE, 80A, 600VAC, 300VDC, 300000A (IR), INLINE/HOLDER
CategoryCircuit protection   
File Size136KB,3 Pages
ManufacturerBussmann (Eaton)
Download Datasheet View All

LPS-RK-80SP Online Shopping

Suppliers Part Number Price MOQ In stock  
LPS-RK-80SP - - View Buy Now

LPS-RK-80SP Overview

TIME DELAY BLOW ELECTRIC FUSE, 80A, 600VAC, 300VDC, 300000A (IR), INLINE/HOLDER

Bussmann
®
LOW-PEAK
®
Dual-Element, Time-Delay Fuses
Class RK1 –– 600 Vac/300 Vdc
Dimensional Data
LPS-RK
70-600A
NEW
A
DES
IGN
B
Dimensions
(inches)
Ampere Ratings
70-100
110-200
225-400
450-600
7.88
9.63
11.63
13.38
“A”
(± 0.062)
(± 0.062)
(± 0.094)
(± 0.094)
1.11
1.61
2.36
2.88
“B”
(± 0.020)
(± 0.020)
(± 0.020)
(± 0.020)
Catalog Symbol:
LPS-RK_SP (600V)
Ampere Rating:
70 to 600A
Voltage Rating:
ac: 600V (or less)
dc: 300V (or less)
Interrupting Rating:
ac: 300,000A RMS Sym.
dc: 100,000A
Agency Information:
UL Listed–Special Purpose**, Guide JFHR, File E56412
CSA Certified, (200,000 AIR) Class 1422-02, File 53787,
Class RK1 per CSA C22.2 No. 248.12
Catalog Numbers
LPS-RK-70SP
LPS-RK-80SP
LPS-RK-90SP
LPS-RK-100SP
LPS-RK-110SP
LPS-RK-125SP
LPS-RK-150SP
LPS-RK-175SP
LPS-RK-200SP
LPS-RK-225SP
LPS-RK-250SP
LPS-RK-300SP
LPS-RK-350SP
LPS-RK-400SP
LPS-RK-450SP
LPS-RK-500SP
LPS-RK-600SP
Features:
• High degree of current-limitation for maximum short-circuit
protection.
• Type 2 protection for IEC and NEMA starters when
properly sized.
• High inrush current motor protection.
• Time-delay permits 130% FLA sizing for back-up motor over-
load protection, and single-phasing protection.
• Low watt loss power consumption.
• Electrically isolated end caps.
• 300Vdc, UL Listed.
Applications:
• Branch distribution
• Motors
• Transformers
• Solenoids
• General purpose circuits
Available with tin plate option. Add suffix “-TP”. (Ex.: LPS-RK-100SP-TP)
Recommended fuseblocks for
Class R 600V fuses
See Data Sheet: 1111
Carton Quantity and Weight—LPS-RK (600Vac)
Ampere
Ratings
70–100
110–200
225–400
450–600
Qty.
1
1
1
1
Carton
Lbs.
2.20
1.10
2.36
3.44
Weight*
Kg.
1.0
0.5
1.1
1.5
Equipment
Fuse Clips
200A
400A
Fuse Reducers For Class R Fuses
Desired
Fuse (Case)
Size
100A
100A
200A
100A
600A
200A
400A
*Single reducer only (pair not required).
For additional information, see Data Sheet: 1118.
Catalog Number
(Pairs)
600V
No. 2621-R
No. 2641-R
No. 642-R
No. 2661-R
No. 2662-R
No. 2664-R*
*Weight per carton.
** Meets all performance requirements of UL Standard 248-12 for Class RK1
fuses.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
10-2-02
SB02295
Form No. LPS-RK 70-600
Page 1 of 3
Data Sheet: 1002
How to check the number of bytes occupied by the written code, memory usage, and stack overflow when using IAR for MSP430
[size=4]In the tool options, there is an option. There is a message option. Select ALL [/size] [size=4] [/size] [size=4]After the compilation is completed, IAR will give how much code and RAM are occu...
fish001 Microcontroller MCU
Are there really industrial products using rtthread on a large scale?
I have been at the new company for a month, excluding the three weeks during the Chinese New Year, which means I have been deeply involved in rtthread for about half a month. I have already found 3 or...
freebsder MCU
Is Ultra-Wideband Safe?
There are many aspects to discuss when analyzing the security of UWB technology. First, the power of UWB pulses is 1/10000-1/100000, and then the power of the signal emitted by the mobile phone, so ev...
btty038 RF/Wirelessly
Principle and composition of pressure sensor
A pressure sensor is a device that detects pressure and converts the pressure signal into an electrical signal and outputs it linearly. Pressure sensors can be divided into mechanical pressure sensors...
cazsensor Industrial Control Electronics
Tektronix MDO3014 oscilloscope channel fault repair - attached practical solutions for related faults
Recently, a customer sent an oscilloscope for repair . The fault of the oscilloscope was that channel 3 was faulty. Let's take a look at the specific repair process below~1. Instrument model:Tektronix...
agitek安泰维修 Test/Measurement
[National Technology N32WB452 Review] + Bluetooth OTA Upgrade
[National Technology N32WB452 Review] + Bluetooth OTA Upgrade (Successful Edition)Preface:In the previous article, due to hardware failure, only theoretical analysis and C language analysis were done....
小火苗 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号