ø22mm - TW Series
Switches & Pilot Devices
Conforming to Standards
Approvals
®
Switches & Pilot Devices
EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
File No. E68961
File No. LR21451
Certificate No.
2030010305027380
Signaling Lights
Registration No: J9551802 (E-Stops)
Registration No: J9551803 (All other switches)
Registration No: J9551804 (Pilot Lights)
Operating Temperature
Vibration Resistance
Shock Resistance
Electric Shock Protection
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
Mechanical Life
Pollution Degree (conforming to IEC60947-1)
Rated Operational Characteristics
Rated Insulation Voltage
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot
lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380,
400/440, 480V)
UL:
pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights
and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440,
480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illumi-
nated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110,
115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing)
5 to 55Hz, 100m/sec
2
(10g) conforming to IEC6068-2-6
1000m/sec
2
(100g) conforming to IEC6068-2-7
Class 0 conforming to IEC60536
IP65 from front of the panel; (IP54 for key switches)
IP20 (Type HW-F contact block)
Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches)
Momentary pushbuttons: 5,000,000 (900 operations per hour)
All other switches: 500,000
3 for switches not using a transformer, 2 for switches using a transformer
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
600V
Less than 4kV, conforming to IEC60947-1
4kV for contact circuit, 2.5kV for lamp circuit
10 Amp
5 mA at 3V AC/DC
Slow break NC or slow make NO, self-cleaning
0.8 N m (7.1 in lb.)
10A 250V fuse conforming to IEC60269-1
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Initial contact resistance of 50mΩ or less
4mm (NO and NC), 2mm (NO-EM and NC-LB)
MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Incandescent: 1 W
LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max
1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor)
40 A (40 ms)
Silver
Contact Block
Rated Insulation Voltage
Rated Continuous Current
Contact Ratings by Utilization Category
IEC 60947-5-1
Type HW-C/HW-F
600V
10A
AC-15 (A600)
DC-13 (P600)
Relays & Sockets
Specifications
Contact Ratings
Timers
Rated Switching Over-Voltage
Rated Impulse Withstanding Voltage
Rated Thermal Current
Minimum Switching Capacity
Contact Operation
Recommended Terminal Torque
External Short-Circuit Protection
Contactors
Applicable Wire Size
Contact Resistance
Contact Gap
Electrical Reliability
Lamp Ratings
Horsepower Rating
Terminal Blocks
Maximum Inrush Current
Contact Material
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Contact Ratings by Utilization Category
Characteristics
Circuit Breakers
Operational Voltage
AC50/60Hz
Operational Current
DC
AC-12 Control of resistive loads and solid state loads
AC-15 Control of electromagnetic loads (> 72VA)
DC-12 Control of resistive loads and solid state loads
DC-13 Control of electromagnets
24V
10A
10A
8A
5A
48V
—
—
5A
2A
50V
10A
7A
—
—
110V
10A
5A
2.2A
1.1A
220V
6A
3A
1.1A
0.6A
440V
2A
1A
—
—
612