6CUFS1
15CUE1
CU Series
• Designed for popular 1U (1 ¾”) height rack
mounted equipment
• Two function power entry module combining
a SPST switch and an IEC 60320-1 inlet
• Snap–in, flange and flush mounting
• Reduce OEM wiring time with optional
pre–connected line and switch terminals
Specifications
Maximum leakage current each Line to Ground:
Filtered
Unfiltered
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
Hipot rating (one minute):
Line to Ground:
Line to Line:
Operating Voltage:
Operating Frequency:
Rated Current:
Switch:
Terminal Push–on Force:
.25 mA
.40 mA
2
A
5
A
2250 VDC
1450 VDC
120/250 VAC
50/60 Hz
1 to 15A*
50A inrush capable SPST
15 lb. / 67N (max.)
Ordering Information
15 CU 10 B S 1
Output Styles
1 – .187 [4.8] spade terminals
Mounting Styles
E – Flange Mount
(Horizontal)
F – Flush Mount
(Filtered only)
S – Snap–in
Filter Type or Terminal Option
F – General purpose
B – No filter, includes
pre–connected terminals
Omit if none
Side Snap–in Option
Non-filtered versions only
Available Part Numbers
1CUFE1
3CUFE1
6CUFE1
10CUFE1
15CUFE1
Filtered Versions
1CUFF1
3CUFF1
6CUFF1
10CUFF1
15CUFF1
Non–filtered Versions
1CUFS1
3CUFS1
6CUFS1
10CUFS1
15CUFS1
Standard Terminals
Pre-connected Terminals
10 – Side snaps
1.0mm max. panel
15 – Side snaps
1.5mm max. panel
Omit for none or
standard configuration
CU Series
Current Rating
1, 3, 6, 10 or 15A
134
15CUE1
15CUS1
15CU10S1
15CU15S1
15CUBE1
15CUBS1
15CU10BS1
15CU15BS1
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Compact 1U Height Switched Power Entry Module
Catalog: 1654001
Issue Date: 06.2011
(continued)
CU Series
Electrical Schematic
LINE
LOAD
CUFS1
C
Case Styles
CUFE1
A
½
½
½
B
½
C
CUE1
F
A
½
½
½
½
3
Power Inlet Filters & Power Entry Modules
C
F
A
B
B
CUFF1
C
½½
½
½
½
CUS1
F
A
B
C
A
½½½
½
½
½
½
B
½½
½
½
½
135
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Compact 1U Height Switched Power Entry Module
Catalog: 1654001
Issue Date: 06.2011
(continued)
CU Series
Case Styles
(continued)
CU10S1 & CU15S1
Case Dimensions
Part No.
CUFE1
A
½
B
½
C
½
C
CUFF1
CUFS1
A
B
½½½½
½½
½
½
½
CUBE1 Pre-Connected Terminals
CUE1,
CUBE1
CUS1,
CUBS1
10CUS1,
10CUBS1
15CUS1,
15CUBS1
D
E
F
Recommended Panel Cutout
F
R. Max
D
CUBS1 Pre-Connected Terminals
E
½
CU10BS1 & CU15BS1
Pre-Connected Terminals
½
½½
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
136
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Compact 1U Height Switched Power Entry Module
Catalog: 1654001
Issue Date: 06.2011
(continued)
CU Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1CUF
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
3CUF
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
6CUF
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
10CUF
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
15CUF
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
3
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Power Inlet Filters & Power Entry Modules
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
137
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.