EEWORLDEEWORLDEEWORLD

Part Number

Search

A150C125-40

Description
Electric Fuse, 125A, 1500VAC, 40000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size2MB,6 Pages
ManufacturerMersen
Websitehttps://www.mersen.com/
Environmental Compliance

With over 135 years of experience, more than 50 industrial sites and 18 R&D centers in 35 countries, Mersen Electrical Power is a global expert in power and advanced materials for high-tech industries. They offer a broad portfolio of electrical protection and control products and provide solutions for power management applications. The Mersen team works with customers around the world to design and deliver custom solutions and essential products for the commercial, industrial, renewable energy, power electronics and electric vehicle markets. Mersen's mission is to make its customers' applications safer and more reliable.

Download Datasheet Parametric View All

A150C125-40 Overview

Electric Fuse, 125A, 1500VAC, 40000A (IR), Inline/holder,

A150C125-40 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerMersen
Reach Compliance Codecompliant
ECCN codeEAR99
body height121.4 mm
Body length or diameter27.9 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Joule integral nominal130 J
Installation featuresINLINE/HOLDER
physical size27.9mm x 121.4mm
Rated breaking capacity40000 A
Rated current125 A
Rated voltage (AC)1500 V
surface mountNO
Terminal shapeTAB/BLADE

A150C125-40 Preview

Download Datasheet
AMP-TRAP
®
MEDIUM VOLTAGE CAPACITOR FUSES/A100C-A550C
MEDIUM VOLTAGE CAPACITOR FUSES
Ferraz Shawmut capacitor fuses are designed to
ANSI C37-41. They are current limiting operating
without noise or discharge and are designed to be
used indoors in a general purpose enclosure or
outdoors in a weatherproof enclosure. These are
non-disconnecting fuses requiring the use of a
disconnect switch. These capacitor fuses provide
both short circuit and overload protection and are
intended to protect against capacitor case rupture
or dielectric failure within the capacitor.
The various mounting configurations offer manu-
facturers a wide range of cost and space saving
solutions and a large choice of equivalent products
to users.
APPLICATIOnS:
Capacitor Protection
Power Factor Correction Equipment
Harmonic Filtering Equipment
Induction Heating System
High Power Drive
Welders
Features/Benefits
High interrupting capacity
Current limitation
Blown fuse indication
Direct mount
Clip style mount
Bus mount
non-venting for silent operation
Ratings
A100C
AC:
25 to 125 Amps, 1000 V Maximum,
50 kA I.R. Sym.
A150C
AC:
25 to 200 Amps, 1500 V Maximum,
40 kA I.R. Sym.
A250C
AC:
25 to 200 Amps, 2500 V Maximum,
50 kA I.R. Sym.
A300C
AC:
50 to 175 Amps, 3000 V Maximum,
50 kA I.R. Sym.
A430C
AC:
6 to 100 Amps, 4300 V Maximum,
65 kA I.R. Sym.
A550C
AC:
6 to 50 Amps, 5500 V Maximum,
65 kA I.R. Sym.
E
Catalog numbering System
A 250 C 125 - 30
Voltage Rating ÷ 10
(250 = 2.5kV)
Current Rating
Mounting Configuration
AC Voltage
Capacitor Fuse
E 
E 
【LAUNCHXL-CC2650】Pressure gasket pressure test
First, let's introduce the sensor used for pressure gaskets - thin film pressure sensor. Thin film pressure sensor is a resistive sensor. The output resistance decreases as the pressure applied to the...
a736015 RF/Wirelessly
Selection of diodes for analog circuits
I added a "diode clamp circuit" to the analog input interface circuit to protect the input of the op amp circuit. There are three problems: 1. Is this circuit necessary? Will it cause large input erro...
bigbat Analog electronics
A Brief Analysis of High-Speed Laser Marking Control System Based on DSP
The galvanometer scanning laser marking technology is to change the propagation direction of the laser by controlling the deflection angle of two high-speed galvanometers, focusing the laser on the wo...
fish001 DSP and ARM Processors
About USB2.0 plug-in and switch
Can I use a high-speed analog switch such as TS3USB31 to switch DM/DP? According to the 3.0 protocol, the complete insertion/removal process needs to detect the VBus timing, and if only the data line ...
Ejack1979 Integrated technical exchanges
[Atria AT32WB415 Series Bluetooth BLE 5.0 MCU] + Bluetooth communication
[Atria AT32WB415 Series Bluetooth BLE 5.0 MCU] + Bluetooth communicationBluetooth BLE Application NotesAfter checking the official website, I found the Bluetooth manual and started to learn and unders...
雨夜很凉快 RF/Wirelessly
xilinx vivado xdc constraint syntax
1. Purpose of Constraints Introduce the principle of FPGA constraints, understand that the purpose of constraints is to serve the design, to ensure that the design meets the timing requirements, and t...
zxopenljx EE_FPGA Learning Park

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号