The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
NEW
0.5mm pitch, 0.9mm above the board,
Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
FH19C & FH19SC Series
FH19C – FPC/FFC thickness: 0.2±0.03mm
Actuator color: Brown
FH19SC – FPC/FFC thickness: 0.3±0.03mm
Actuator color: Black
s
Features
1. Low-profile 0.5mm pitch FPC/FFC Connectors
Miniaturization of portable equipment and personal mobile
devices has created increased demand for a low profile,
high density, and high reliability connectors.
*The
design of this connector has been made thinner and
smaller, with a height of 0.9mm and width of 3mm.
*PCB
footprint: Reduced approximately 48% (as compared with
Hirose Electric's 0.5mm pitch FH12 Series connectors)
*Connector
weight: Reduced approximately 78% (as compared
with Hirose Electric's 0.5mm pitch FH12 Series connectors)
q
0.9mm high
0.9mm
m
17m
q
Can be mounted over conductive traces
2. Conductive traces on the PCB can run under
the connector
All bottom surface of the connector is solid, without any
exposure of the contact.
3. Proven Flip-Lock Actuator System assures
easy and reliable operation
Rotating actuator permits easy insertion and reliable
connection with the FPC & FFC.
Tactile sensation confirms complete mechanical locking of
the actuator and the electrical connection.
Enclosed construction
(No exposed contacts)
Metal fittings
(Leadless)
4. Accepts 0.2mm & 0.3mm thick FPC/FFC
No exposed contacts on the bottom of the connector.
The connector will also terminate with 0.2mm thick Flat
Flexible Cable (FFC).
q
Metal Fittings (Leadless Type)
No protrusions on the sides
allows close side-by-side
board placement.
5. Board placement with automatic equipment
Flat top surface and packaged on the tape-and-reel allows
use of vacuum nozzles.
Standard reel contains 5,000 pieces.
q
Actuator Temporary Hold Mechanism
s
Applications
Notebook PC’s, PDA’s, digital cameras and other compact
devices requiring interconnections of the main circuit board
with the LCD, plasma display (PDP), HDD or other compact
devices requiring FPC/FFC connections using low profile,
high reliability ZIF connectors.
Actuator stays open during insertion of the FPC/FFC.
3m
m
2006.9
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sProduct
Specifications
Current rating 0.5 A DC
Rating
Voltage rating 50 V AC
Recommended
FPC, FFC
FH19C Series
FH19SC Series
Operating temperature range
-55ç
to +85ç (Note 2)
Operating humidity range
Relative humidity 90% max. (No condensation)
Storage temperature range
-10ç
to +50ç (Note 3)
Storage humidity range
Relative humidity 90% max.
Thickness: = 0.2
±
0.03mm Gold or tin-lead plated (Note 3)
Thickness: = 0.3
±
0.03mm Gold or tin-lead plated (Note 3)
Item
1. Insulation resistance
2. Withstanding voltage
3. Contact resistance
4. Durability
(insertion/ withdrawal)
5. Vibration
Specification
500 M ohms min.
No flashover or insulation breakdown
100 m ohms max.
*Including
FPC/FFC conductor resistance
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1
µ
s or more.
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1
µ
s. min.
Contact resistance: 100 m ohms max.
No damage, cracks, or parts dislocation.
Contact resistance: 100 m ohms max.
Insulation resistance: 100 M ohms min.
No damage, cracks, or parts dislocation.
Contact resistance: 100 m ohms max.
Insulation resistance: 100 M ohms min.
No damage, cracks, or parts dislocation.
100 V DC
150 V AC/1 minute
1 mA
20 cycles
Conditions
Frequency: 10 to 55 Hz, single amplitude of
0.75mm, 10 cycles in each of the 3 directions
Acceleration of 981 m/s
2
, 6 ms duration, sine half-
wave waveform, 3 cycles in each of the 3 axis.
96 hours at temperature of 40ç and humidity of
90 to 95%
Temperature:
-55ç
/
+15ç to +35ç
/
+85ç
/
+15ç to +35ç
Time
:
-30
/
2 to 3
/
+30
/
2 to 3(Minutes)
5 cycles
Reflow: At the recommended temperature profile
6. Shock
7. Humidity
(Steady state)
8. Temperature cycle
9. Resistance to
soldering heat
No deformation of components affecting performance.
Manual soldering: 350ç±5ç for 5 seconds
Note 1: When passing the current through all of the contacts, use 70% of the current rating.
Note 2: Includes temperature rise caused by current flow.
Note 3: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non- conducting condition of installed connectors in storage, shipment or during transportation.
Note 4: When FPC is gold plated, the connector contacts must be also gold plated: Select the (05) code.
sMaterials
Part
Insulator
Actuator
Contacts
Metal fittings
Material
LCP
PPS/LCP
Phosphor bronze
Phosphor bronze
Finish
Color: Beige
Color: Brown (FH19C Series)
Color: Black (FH19SC Series)
Gold flash or Tin-lead plated (Note 4)
Pure tin reflow plated
Remarks
UL94V-0
-------
-------
sOrdering
information
FH19
1
1
Series name :
2
C :
SC :
FH19
C - 30S - 0.5 SH (05)
2
3
4
4
Contact pitch :
5
Terminal type
SH: SMT horizontal mounting type
5
6
0.5mm
FPC/FFC thickness : 0.2mm
FPC/FFC thickness : 0.3mm
4 to 50
3
No. of contacts :
6
Material and plating specifications :
Actuator material
FH19C
FH19SC
FH19SC
Contact: Gold flash plated
Contact: Tin-lead plated
Contact: Gold flash plated
Contact: Gold flash plated
PPS
------
------
(05)
(51)
------
------
LCP
(05)
(51)
------
------
(05)
(51)
4 to 10 pos. Contact: Tin-lead plated
11 to 50 pos. Contact: Tin-lead plated
2
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sConnector
Dimension
[FH19C Series]
A±0.15
B
G
0.5
∞Number of contacts
0.15 G
(0.15)
+0.15
0
3
A
(0.5)
Polarizing mark indicator
Number of contacts indicator
(130°)
(1.6)
(0.15)
(C: FPC insertion slot dimension)
D±0.1
2.15±0.2
2
1
0.15MAX
(1.3)
0.15MAX
S
1
2
Notes 1 The coplanarity of each terminal lead and metal fitting is within 0.1
2 The contact terminal lead position indicates the dimension from the bottom surface of the insulator body.
3 Difference between terminal contact to be max. 0.1mm.
4 Any discoloration of the plastic compound will NOT AFFECT form, fit or function of the connector.
Note that preventive hole for sink mark could be added for improvement.
Note2: When selecting the RoHScompliant code (05) as gold plated contacts.
Code (51) is not RoHS compliant.
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
[FH19SC Series]
A±0.15
B
0.5
∞Number of contacts
0.15 G
+0.15
0
3
G
(0.15)
A
6
(0.5)
Polarizing mark indicator
Number of contacts indicator
(130°)
(1.6)
(0.15)
(C: FPC insertion slot dimension)
D±0.1
2.15±0.2
2
1
0.15MAX
(1.3)
0.15MAX
S
1
2
Notes 1
2
3
4
5
The coplanarity of each terminal lead and metal fitting is within 0.1
The contact terminal lead position indicates the dimension from the bottom surface of the insulator body.
Difference between terminal contact to be max. 0.1mm.
Any discoloration of the plastic compound will NOT AFFECT form, fit or function of the connector.
The contacts are protruding. 0.03mm max. from the housing top surface.
Note2: When selecting the RoHScompliant code (05) as gold plated contacts.
Code (51) is not RoHS compliant.
4
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
B
Recommended PCB Land and Metal Mask Dimensions
[Common to FH19C & FH19SC Series]
Recommended metal mask thickness: 0.10 mm.
B ∞Number of contacts
0.8±0.05
H
(0.15)
(0.15) (0.15)
(0.2)
K±0.1
(A)
2-
R0
.2
0.5
0.3±0.05 (Land)
0.1 H
0.25±0.05 (Metal mask)
3.3±0.05
0.8±0.05
J±0.1
B
Recommended FPC, FFC Dimensions
[Common to FH19C & FH19SC Series]
L±0.05
0.5±0.07
0.5±0.03
B±0.03
0.35±0.03(FPC)
0.3±0.03(FFC)
FH19C Series FH19SC Series
0.2±0.03
0.3±0.03
2.5±0.3
(Exposed traces)
(0.15)
(0.05)
(2.5)
(3)
Note1: Polyamide and a thermally hardened adhesive is recommended as the materials for the stiffener.
Note2: Stiffener dimension should be 3.5mm min., and X dimension should be 0.5mm for improved flexibility of FPC.