High Current
Filtered Terminal Blocks
Features
I
I
I
I
Ideal for high current applications
Design flexibility
Available in 2 x 2 through 2 x 6 positions
UL approved
Applications
Telecommunications switching networks
I
Cellular base stations
I
Power supplies
I
UPS
I
Instrumentation
I
High reliability radar and transmission systems
I
Industrial controls
I
Power distribution
I
Specifications
ELECTRICAL
Voltage rating:
Capacitance:
100 VDC per terminal
.015µF* +80% / -20% per cap
.030µF +80% / -20% per pair
Dielectric
withstanding voltage:
1000VDC for 1 minute
Current rating:
60 Amps max per terminal
Typical Insertion Loss — dB:
In 50 Ohm Circuit
1
5
10
50
MHz....... 8
MHz....... 24
MHz....... 32
MHz....... 38
70
100
160
200
MHz......... 36
MHz......... 33
MHz......... 25
MHz......... 25
4.600 (116.8)
8-32 THREADED
INSERTS (4X)
1.625
(41.3)
R.125 (3.2)
(4X)
.65 MIN (16.5)
(6X)
1.10 (27.9)
1.15 (29.1)
.80 MIN (20.3)
MECHANICAL
Center spacing:
Wire size:
Screw material:
Recommended PCB
hole diameter:
Molded material:
Tightening torque:
Terminal:
US .200: (5.08 mm)
AWG #12-26
Steel, zinc chromate plate
.05" (1.30 mm) contact hole
UL rated 94VO polyamide
2.5 in.-lbs. max. (28 Ncm)
Brass, tin-plated
.75 (19.0)
(5X)
.172 (4.3)
(4X)
2.625 2.025 .75 (19.0)
(66.7) (51.4)
PANEL CUTOUT
4.6 (116.8)
5.0 (127)
1.685 2.025
(42.8) (51.4)
* For filter elements with additional capacitance values,
consult factory.
5.0 (127)
5.6 (142.2)
Part
Number
52-1013-102
52-1013-103
52-1013-104
52-1013-105
52-1013-106
Number of
Terminals
2x2
2x3
2x4
2x5
2x6
2.60
3.35
4.10
4.85
5.60
in.
A
(mm)
66.04
85.09
104.14
123.19
142.24
2.00
2.75
3.50
4.25
5.00
in.
B
(mm)
50.80
69.85
88.90
107.95
127.00
1.66
2.41
3.16
3.91
4.66
in.
C
(mm)
42.16
61.21
80.25
99.31
118.36
Dimensions in inches
(mm)
API TECHNOLOGIES
• 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF15