Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation
Note4: add suffix „/X2“ for single output with alternative pinout
Note5: add suffix „P“ for continous short circuit protection
EN/IEC60950-1 certified
EN/IEC60601-1 certified
UL/CSA 60950-1 certified
ES/CSA60601-1 certified
EN/IEC61010-1 certified
IEC-60601-1 CB report
www.recom-power.com/eval-ref-boards
www.recom-power.com
REV.: 4/2018
ECO-1
RxxP2xxS_D/R
DC/DC Converter
Specifications
(measured at Ta= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Minimum Load
(6)
Internal Operating Frequency
Output Ripple and Noise
(7)
20MHz BW
Notes:
Note6: Operation below 10% load won‘t harm the converter, but specifications may not be met
Note7: Measurements are made with a 0.1µF MLCC across output (low ESR)
0%
20kHz
50kHz
85kHz
200mVp-p
Series
Condition
Min.
Typ.
±10%
Max.
Efficiency vs. Load
RxxP205S/R6.4 and
RxxP205S/R8
RxxP205D/R6.4 and
RxxP205D/R8
100
90
80
70
60
50
40
30
20
10
0
0
10
20
100
90
80
70
60
50
40
30
5Vin
12Vin
24Vin
Efficiency [%]
Efficiency [%]
20
10
0
0
10
20
30
40
50
60
70
5Vin
12Vin
24Vin
30
40
50
60
70
80
90 100
80 90 100
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
low line to high line, full load
10% to 100% load
3.3V, 5V
9V, 12V, 15V
Condition
Value
±5.0% max.
±1.0% typ. / ±1.2% max.
±15.0% typ.
±10.0% typ.
Deviation vs. Load
RxxP205S/R6.4 and
RxxP205S/R8
5Vin
12Vin
24Vin
30
25
20
15
10
5
0
-5
-10
0
10
20
30
25
20
15
10
5
0
-5
-10
RxxP205D/R6.4 and
RxxP205D/R8
5Vin
12Vin
24Vin
Deviation [%]
30
40
50
60
70
80
90 100
Deviation [%]
0
10
20
30
40
50
60
70
80
90 100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 4/2018
Output Load [%]
ECO-2
RxxP2xx/R
DC/DC Converter
Specifications
(measured at Ta= 25°C, nominal input voltage, full load and after warm-up)
Tolerance Envelope
Series
Output Voltage [%]
+10%
+5%
Vnom
Typical L
o
ad Line
+5%
-1.5%
-5%
10
50
100
Load [%]
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Type
without Suffiy “P”
With Suffix “P”
I/P to O/P
tested for 1 second
I/P to O/P
rated for 1 minute
/R6.4
/R8
/R6.4
/R8
Value
1 second
continuos
6.4kVDC
8kVDC
3200VAC/60Hz
4000VAC/60Hz
15GΩ min.
Isolation Voltage
(8)
Isolation Resistance
Isolation Capacitance
Insulation Grade
Means of Protection
Internal
External
1.5pF min./10.0pF max.
reinforced
34Vrms
2MOPP
5.5mm
4.95mm
clearance/creepage
clearance/creepage
Notes:
Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Operating Humidity
Pollution Degree
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
non-condensing
Condition
without derating @ natural convection 0.1m/s (see graph)
Value
-40°C to +85°C
+105°C
95% RH max.
PD2
1154 x 10
3
hours
168 x 10
3
hours
continued on next page
www.recom-power.com
REV.: 4/2018
ECO-3
RxxP2xxS_D/R
DC/DC Converter
Specifications
(measured at Ta= 25°C, nominal input voltage, full load and after warm-up)
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
80
70
60
50
40
30
20
10
0
-40 -20
0
20
40
60
80 100 120
85
Series
Output Load [%]
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety (LVD)
Information Technology Equipment, General Requirements for Safety
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Safety requirements for electrical equipement for measurement,
control and laboratory use
RoHs 2+
T1301251-313
Report / File Number
SPCLVD1605077-14
2236395
E314885-A5-UL
Standard
EN60950-1: 2006 + A2:2013
IEC60950-1-2005 , 2nd Edition + A2:2013
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No. 60601-1
IEC/EN 60601-1, 3rd Edition
EN61010:2010
IEC61010:2010, 3rd Edition
RoHS (10/10)
EMC Compliance
Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement
Condition
with external filter
Standard / Criterion
EN55022, Class A/B
EMC Filtering Suggestions according to EN55022
L1
+Vin
C1
-Vin
C3
Component List Class A
MODEL
RxxP2xx/R6.4
10µF
RxxP2xx/R8
N/A
N/A
+Vout
C2
-Vout
Component List Class B
L1
C2
C3
2n2F 8kV
Vishay HGZ222MBP
2n2F 10kV
Vishay HGZ222MBP
C1
MODEL
RxxP2xx/
R6.4
RxxP2xx/R8
C1
10µF
L1
470µH
WE 7447471471
C2
10µF
C3
2n2F 8kV
Vishay HGZ222MBP
2n2F 10kV
Vishay HGZ222MBP
ECO-4
www.recom-power.com
REV.: 4/2018
RxxP2xxS_D/R
DC/DC Converter
Specifications
(measured at Ta= 25°C, nominal input voltage, full load and after warm-up)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Series
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94V-0)
silicon rubber compound, (UL94V-0)
FR4, (UL94V-0)
19.5 x 9.8 x 12.5mm
4.3g typ.
Dimension Drawing (mm)
embossed logo
19.5
9.8
12.5
Marking
0.51
4.10
0.50
0.25
Recommended Footprint Details
1.00 Ø +0.15/-0
Bottom View
1 2
1.9
5
6x2.54= 15.24
6 7
2.54
2.4
Top View
Pin Connection
Pin # Single
1
+Vin
2
-Vin
5
-Vout
6
No Pin
7
+Vout
Tolerance:
Dual
+Vin
-Vin
-Vout
Com
+Vout
/X2
+Vin
-Vin
No Pin
-Vout
+Vout
2.54
xx.x= ±0.5mm
xx.xx= ±0.25mm
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
Type
tube
tube
Value
520.0 x 23.3 x 12.0mm
25pcs
- 55°C to +125°C
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.