HA AND HD SERIES | 60
PANEL MOUNT
Features
• Ratings from 25A to 125A @ 48-660 VAC
• SCR output for heavy industrial loads
• Zero Voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC or DC control
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
PRODUCT SELECTION
Control Voltage
4-32 VDC
90-280 Vrms
18-36 Vrms
25A
HD6025
HA6025
HA6025E
50A
HD6050
HA6050
HA6050E
90A
HD6090
HA6090
HA6090E
125A
HD60125
HA60125
HA60125E
ORDERING OPTIONS
H
Serires
H
Control Voltage
A:
90-280 VAC
D:
4-32 VDC
AxxxxE:
18-36 VAC
Operating Voltage
60:
48-660 VAC
A
60
25
E
K
P
G
H
-10
Rated Load Current
25:
25 Amps
50:
50 Amps
Termination
90:
90 Amps
125:
125 Amps
Blank:
Screw
F:
Quick Connect (Up to 50 Amps only)
(1)
K:
Hex standoffs
(2)
Overvoltage Protection
Blank:
Not Included
P:
Included
(3)
Input Status LED
Blank:
Not Included
G:
Included
Thermal Pad
Blank:
Not Included
H:
Included
Switching Type
Blank:
Zero Voltage Turn-On
-10:
Instantaneous Turn-On
(4)
Required for valid part number
For options only and not
required for valid part number
Note:
Not all part number combinations are available.
Contact Crydom Technical support for information on
the availability of a specific part number.
Page 1
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
OUTPUT SPECIFICATIONS
Descrption
Operating Voltage (47-440Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Load Current [Arms]
(2)(6)
Minimum Load Current [mArms]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor ( at Maximum Load)
(3)
(5)
25A
48-660
1200
1.0
500
25
150
235/250
1.15
0.8
285/259
0.5
50A
48-660
1200
1.0
500
50
150
597/625
1.15
0.45
1770/1629
0.5
90A
48-660
1200
1.0
500
90
150
1145/1200
1.15
0.27
6560/5976
0.5
125A
48-660
1200
1.0
500
125
150
1670/1750
1.15
0.22
13950/12709
0.5
INPUT SPECIFICATIONS
Description
Control Voltage Range
Minimum Turn-On Voltage
Must Turn-Off Voltage
Maximum Reverse Voltage
Minimum Input Current
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
(5)
HD60xx
4-32 VDC
4.0 VDC
(7)
1.0 VDC
-32 VDC
7.0 mA
12 mA
1/2 Cycle
(8)
1/2 Cycle
(5)
HA60xx
90-280 Vrms
90 Vrms
10 Vrms
-
5 mA
10 mA
Current Regulated
20
30
HA60xxE
18-36 Vrms
18 Vrms
4.0 Vrms
-
16 mA
20 mA
20
30
GENERAL SPECIFICATIONS
Description
Parameters
4000 Vrms
10
9
Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
2.6 oz (74.9 g)
UL94 V-0
Aluminum
13-15 /1.5-1.7
18-20 / 2.0-2.2
18-20 / 2.0-2.2
w/”K” option 8-10 / 0.9-1.13
#6-32 UNC / #8-32 UNC
93% non-condensing
w/”G” option (green)
11,641,553 hours (1,328 years)
7,210,376 hours (823 years)
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Baseplate Material
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
SSR Mounting Screw Torque Range (in-lb/Nm)
Input/Load terminal Screw Torque Range (in-lb/Nm)
(2)
Input/Output Terminal Screw Thread Size
Humidity
per IEC60068-2-78
LED Input Status Indicator
MTBF (Mean Time Between Failures) at 40°C ambient temperature
(9)
MTBF (Mean Time Between Failures) at 60°C ambient temperature
(9)
WIRING DIAGRAM
AC
V
Recommended Wire Sizes
Load
(10)
Terminals
Wire Size
(Solid / Stranded)
24 AWG (0.2 mm
2
) / 0.2 [minimum]
2 x 12 AWG (3.3 mm
2
) / 3.3 [maximum]
20 AWG (0.5 mm
2
) / 0.518 [minimum]
Wire Pull-Out
Strength (lb)[N]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
Input Current (mA)
25
20
15
10
5
0
0
Input Current vs Input Voltage
Standard Regulated DC Input
1 ( )
2 ( )
Input
1
OUTPUT
2
Output
2 x 10 AWG (5.3 mm
2
)
/ 5.3
2 x 8 AWG (8.4 mm
2
) / 8.4 [maximum]
S O L I D S TAT E R E L AY
4
INPUT
3
5
10
15
20
25
30
DC Input Voltage
4 (– / )
3 (+ / )
Page 2
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
Diagram:
HD60xx
-DC
4
1
AC
AC
4
AC/DC
Converter
2
AC
AC
3
Current
Limiter
Diagram:
HAxxxx
1
AC
Trigger
Circuit
(11)
Trigger
Circuit
(12)
(12)
2
AC
(11)
+DC
3
Current
Limiter
MECHANICAL SPECIFICATIONS
(5)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Screw Termination
1.1
[27.9]
0.49
[12.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
0.89
[22.6]
Hex Standoff Termination (“K”
Option)
(2)
1.1
[27.9]
0.49
[12.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.04
[26.4]
1
OUTPUT
2
1
OUTPUT
2
1.88
[47.6]
S O L I D S TAT E R E L AY
1.7
[43.2]
2.25
[57.3]
1.88
[47.6]
S O L I D S TAT E R E L AY
1.70
[43.2]
2.25
[57.3]
4
INPUT
3
4
INPUT
3
1.0
[25.4]
1.75
[44.5]
1.0
[25.4]
1.75
[44.5]
(4 places)
(2 places)
1.0
[25.4]
0.93
[23.6]
Quick Connect Termination (“F”
Option)
- Up to 25 Amp
(1)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.58
[40.2]
0.49
[12.4]
Faston Terminal
(13)
0.25 x 0.032
Quick Connect Termination (“F”
Option)
- Up to 50 Amp
(1)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.58
[40.2]
0.63
[16.0]
Faston Terminal
(13)
0.25 x 0.032
1.31
[33.4]
(2 places)
(4 places)
1.31
[33.4]
(2 places)
1
2
0.45
[11.4]
1
OUTPUT
2
OUTPUT
1.88
[47.6]
S O L I D S TAT E R E L AY
1.7
[43.2]
2.25
[57.3]
4
1.88
[47.6]
S O L I D S TAT E R E L AY
1.7
[43.2]
2.25
[57.3]
INPUT
3
4
INPUT
3
1.40
[35.6]
1.75
[44.5]
Faston Terminal
(13)
0.187 x 0.020
(2 places)
1.25
[31.8]
0.49
[12.4]
1.40
[35.6]
1.75
[44.5]
Faston Terminal
(13)
0.187 x 0.020
(2 places)
1.25
[31.8]
Page 3
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
SURGE CURRENT INFORMATION
25 A
250
Surge Current (Amp)
Surge Current (Amp)
200
150
100
50
0
0.01
0.1
1
Surge Duration (Secs)
10
600
500
400
300
200
100
0
0.01
0.1
1
Surge Duration (Secs)
10
50 A
90 A
1200
1050
900
750
600
450
300
150
0
0.01
1800
1600
1400
1200
1000
800
600
400
200
0
0.01
Surge Current (Amp)
Surge Current (Amp)
125 A
0.1
1
Surge Duration (Secs)
10
0.1
1
Surge Duration (Secs)
10
Non repetitive peak surge current at Tj initial 40ºC.
THERMAL DERATE INFORMATION
25 A
1.5ºC/W
25
Load Current (Amps)
Load Current (Amps)
20
15
10
5
0
20
30
40
50
60
70
Ambient Temperature (ºC)
80
2ºC/W
3ºC/W
50
40
30
20
10
0
20
30
40
50
60
70
Ambient Temperature (ºC)
80
0.7ºC/W
50 A
1ºC/W
1.5ºC/W
2ºC/W
90 A
0.5ºC/W
90
80
70
60
50
40
30
20
10
0
Load Current (Amps)
0.7ºC/W
1ºC/W
1.5ºC/W
120
Load Current (Amps)
100
80
60
40
20
0
20
30
0.5ºC/W
125 A
0.7ºC/W
1ºC/W
20
30
40
50
60
70
Ambient Temperature (ºC)
80
40
50
60
70
Ambient Temperature (ºC)
80
GENERAL NOTES
(1)
Single pair (up to 25A) Double pair* (up to 50A).
*Caution:
User must connect both
pairs.
(2)
Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals
having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50
Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For
additional application assistance please contact Crydom Technical Support.
(3)
Output will self trigger between 900-1200Vpk, Min. power factor 0.7 or higher, not
suituable for capacitive loads.
(4)
Instantaneous turn-on version is not recomended for capacitive loads. Use zero
turn-on only.
(5)
All parameters at 25°C unless otherwise specified.
For additional information or specific questions, contact Crydom Technical Support.
(6)
Heat sinking required, see derating curves.
(7)
Increase minimum voltage by 1V for operations from -20 to -40°C.
(8)
Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).
(9)
Al parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for
(10)
Load can be wired to either SSR output terminal 1 or 2.
(11)
Elective Input Status LED, “G” option.
(12)
Elective Overvoltage Protection, “P” option.
(13)
Mechanical dimensions vary from G3 models.
Page 4
detailed report).
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
AGENCY APPROVALS AND CERTIFICATIONS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz
IEC 600068-2-27: Shock Resistance 15g/11ms
E116950
LR 81689
REG.- Nr. 10143 (exept 125A models)
ACCESORIES
Protective Cover & Hardware Kits
Part number: KS101
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
Recommended Accessories
Protective Cover
Cover
KS101
Hardware
Kit
HK1
HK4
Heat Sink
Part No.
HS501DR
HS301 / HS301DR
HS251
HS202 / HS202DR
HS201 / HS201DR
HS172
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS101
HS073
HS072
HS053
HS033
HS023
Thermal Resistance
Lug Terminal Thermal Pad
[ºC/W]
5.0
3.0
2.5
2.0
2.0
1.7
1.5
1.2
1.0
1.0
0.7
0.7
0.5
0.36
0.25
TRM1
TRM6
HSP-1
HSP-2
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
Page 5
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com