On-board type
Ordering information
ZUS3
R
ZU
1
2
S
3
3
4
12
5
05
1Series
name
2Single
output
3Output
wattage
4Input
voltage
5Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
ZUS30505
3
VOLTAGE[V] 5
CURRENT[A] 0.60
ZUS30512
3
12
0.25
ZUS30515
3
15
0.20
ZUS31205
3
5
0.60
ZUS31212
3
12
0.25
ZUS31215
3
15
0.20
ZUS32405
3
5
0.60
ZUS32412
3
12
0.25
ZUS32415
3
15
0.20
ZUS34805
3
5
0.60
ZUS34812
3
12
0.25
ZUS34815
3
15
0.20
SPECIFICATIONS
MODEL
VOLTAGE[V]
*
1
CURRENT[A]
INPUT
*
1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
*
2
TEMPERATURE REGULATION[mV] -20 to +55
C
*
3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
ZU/ZT
ZUS30505 ZUS30512 ZUS30515 ZUS31205 ZUS31212
DC4.5 - 9
DC9 - 18
0.896typ 0.857typ 0.857typ 0.357typ 0.338typ
67typ
70typ
70typ
70typ
74typ
5
12
15
5
12
0.60
0.25
0.20
0.60
0.25
20max 48max 60max 20max 48max
40max 100max 120max 40max 100max
80max 120max 120max 80max 120max
120max 150max 150max 120max 150max
50max 150max 180max 50max 150max
20max 48max 60max 20max 48max
20max (Minimum input, Io=100%)
ZUS31215 ZUS32405 ZUS32412
DC18 - 36
0.338typ 0.176typ 0.167typ
74typ
71typ
75typ
15
5
12
0.20
0.60
0.25
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
ZUS32415 ZUS34805 ZUS34812
DC36 - 72
0.167typ 0.088typ 0.082typ
75typ
71typ
76typ
15
5
12
0.20
0.60
0.25
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
ZUS34815
0.082typ
76typ
15
0.20
60max
120max
120max
150max
180max
60max
Fixed
4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
-20 to +71
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with IEC60950-1
35
X
7
X
23mm (W
X
H
X
D) / 16g max
Convection
Rated input. 5V, 12V, 24V or 48V DC, Io=100%
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
G-94