REVISION R
((No OF POS / 16) x .840[21.34]) - .020[.51] REF
DO NOT
SCALE FROM
THIS PRINT
C
((No OF POS / 16) x .840[21.34]) - .035[.89] REF
C
((No OF POS / 16) x .840[21.34]) - .265[6.73]
.115 2.92
REF
.84 21.34 (TYP)
.16 4.00
"A"
.025 0.635 REF
.075 1.91 REF
C
"A"
PACKAGING OPTION
-TR: TAPE & REEL
(-016 THRU -048 WITHOUT OPTIONS
-GP OR -PXX, -016 THRU -032 WITH
OPTIONS -GP OR -PXX)
OPTION
** -GP: GUIDE POSTS
(SEE FIG. 3, SHEET 2)
-K: KAPTON PAD
**
(SEE FIG. 2, SHEET 2)
-PC4: POWER COMBO 4 (.062" THICK BOARD)
(SEE FIG. 5, SHEET 3)
-PC8: POWER COMBO 8 (.062" THICK BOARD)
(SEE FIG. 5, SHEET 3)
ROW SPECIFICATION
-PT4: POWER COMBO 4 (.093" THICK BOARD)
-D: DOUBLE
01
(SEE FIG. 5, SHEET 3)
-DP: DIFFERENTIAL PAIRS
-PT8: POWER COMBO 8 (.093" THICK BOARD)
SEE FIG. 1 FOR SHIELD BEAM CONFIGURATION
(SEE FIG. 5, SHEET 3)
[-PXX NOT AVAILABLE WITH -GP, -A, -K]
OPTION
[-PXX AVAILABLE ON POSITIONS
**-A: ALIGNMENT PIN
-016, -032 & -048 ONLY AND ON
LEAD STYLE -06.75 ONLY]
* = NOT TOOLED
C
** = NOT AVAILABLE WITH PXX OPTION
R
+.0040
+0.102
.1150
- .0020
2.92
- 0.051
.010 0.25 REF
02
(MEASURED TERMINAL
TO TERMINAL)
QMSS-26-06.75-D-XX-A
.069 1.74
REF
.2500 6.35
T-1G19-06.75-L
No OF PAIRS
-016, -032, -048,
-064, * -080
(PER ROW)
LEAD STYLE
-06.75 (SEE FIG. 1, SEE NOTE 9)
PLATING SPECIFICATION
-L: LIGHT GOLD (USE T-1M19-06.75-L)
-H: HEAVY GOLD (USE T-1M19-06.75-H)
(ALL PLATING STYLES USE
SH1-XX-L & T-1G19-06.75-L)
.025[.64] REF
NORMAL FORCE PROTRUSION
C
C
QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX
(4 EQ SPACES @ .0750[1.905]) (TYP)
.125 3.18
REF
.250 6.35
REF
+.0040
.2650
- .0020
6.73
- 0.051
(SEE NOTES 5, 6 & 7)
+0.102
SH1-11-L
T-1M19-06.75-X
C
SEE TABLE 1
.035 0.89 REF
.040 1.02 REF
((No OF POS / 16) x .840[21.34]) - .105[2.67] REF
.075 1.91 REF
.296±.006 7.52±0.15
(SEE NOTE 6)
.022 0.56 REF
-06.75 LEAD STYLE
(QMSS-032-06.75-X-D-DP-A SHOWN)
(MATED HEIGHT WITH QFSS-04.25: .433 [11.00] REF)
FIG. 1
SECTION "A"-"A"
SCALE 4.5 : 1
SEE NOTE 4
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. BURR ALLOWANCE: .0015 MAX.
3. MINIMUM PUSHOUT FORCE: SIGNAL: .5 LB, SHIELD/GROUND: 1 LB, POWER: .5 LB.
4. DO NOT SHEAR TERMINALS SHOWN; THESE UNSHEARED TERMINALS ARE NOT
CONSIDERED IN THE NUMBER OF POSITIONS IN THE CALLOUT BECAUSE THEY
ARE GROUNDED TO THE SHIELDS.
5. MAX VARIANCE OF .002.
6. DIMENSION APPLIES TO CONTACTS & GROUND PLANE.
7. GROUND PLANE PRESS HEIGHT MUST BE .003[.08] LESS THAN THE MAX HEIGHT
OR .001[.03] GREATER THAN THE MINIMUM HEIGHT OF THE TERMINALS.
8. PARTS TO BE PACKAGED IN TRAYS AS STANDARD.
9. LEADSTYLE -11 MAY BE SUBSTITUTED IN PART CALLOUT FOR -06.75
FOR EXISTING CUSTOMERS ONLY
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 2.5:1
PATENT NUMBERS
6739884/ 7165994
7121849
INSULATOR: LCP, COLOR: BLACK
TERMINAL, GROUND PLANE,
& SHIELD: PHOS BRONZE
F:\DWG\MISC\MKTG\QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX-MKT.SLDDRW
.635mm DIFFERENTIAL PAIRS SHIELDED TERMINAL STRIP
DESCRIPTION:
DWG. NO.
QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX
BY:
BRATCHER 08/12/03
SHEET
1
OF
3
REVISION R
IN-PROCESS 1
.25 6.35
IN-PROCESS 2
FLUSH TO .010[.25]
BELOW BODY
.025[.64] REF
NORMAL FORCE PROTRUSION
.2650
- .0020
6.731
- 0.051
(SEE NOTE 5)
+.0040
+0.102
.2650
- .0020
6.73
- 0.051
(SEE NOTE 5)
SEE TABLE 1
+.0040
+0.102
SEE TABLE 1
"B" REF
"A" REF
TERMINAL DETAILS
FIG. 3
.002 MAX
BURR
-GP: GUIDE POST OPTION
(QMSS-032-06.75-X-D-DP-A-GP SHOWN)
SEE NOTE 4
QMSS-26-06.75-D-XX-A-GP
.125 3.18
REF (TYP)
.225 5.72
REF (TYP)
.025[.64] REF
NORMAL FORCE PROTRUSION
.008 0.20
-K: KAPTON PAD OPTION
(USE K-500-300)
(QMSS-032-06.75-X-D-DP-A-K SHOWN)
.22 5.49
.271±.004 6.88±0.10
FIG. 2
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DESCRIPTION:
DO NOT SCALE DRAWING
.635mm DIFFERENTIAL PAIRS SHIELDED TERMINAL STRIP
DWG. NO.
(((No OF POS / 16) x .840[21.34]) - .251[6.38]) / 2
F:\DWG\MISC\MKTG\QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX-MKT.SLDDRW
SHEET SCALE: 2.5:1
QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX
BY:
BRATCHER 08/12/03
SHEET
2
OF
3
REVISION R
"D" REF
"G"
(MEASURED ON POST & TAIL)
"C"
"D"
"C"
IN-PROCESS
P01
"L" REF
"F" REF
("E" EQ SPACE(S) @ .07874[2.000]) (TYP)
.020 0.50 REF
T-1M27-XX-S
"D"
QMSS-26-06.75-D-XX-PCX
(SEE TABLE 5)
C
.132 3.35
P02
.165 4.19
REF
"J"
REF
C
"K"
.022 0.56 REF
C
C
2 MAX SWAY
(TYP)
SECTION "C"-"C"
FIG. 5 -PXX OPTION
POWER COMBO OPTIONS
QMSS-032-06.75-X-D-DP-PC4 SHOWN
(SAME AS FIG. 1, UNLESS OTHERWISE STATED)
[NOT AVAILABLE WITH -GP, -A, OR -K OPTION]
[AVAILABLE ON -016, -032 & -048 POSITIONS ONLY
"H"
REF
.100±.005 2.54±0.13
3 MAX TOE (TYP)
SECTION "D"-"D"
C
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DO NOT SCALE DRAWING
SHEET SCALE: 2.5:1
.635mm DIFFERENTIAL PAIRS SHIELDED TERMINAL STRIP
DESCRIPTION:
DWG. NO.
QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX
BY:
BRATCHER 08/12/03
SHEET
3
OF
3
F:\DWG\MISC\MKTG\QMSS-XXX-XX.XX-X-D-DP-X-XXX-XX-MKT.SLDDRW