ROV Metal Oxide Varistors
E Series Specifications
Table V14 - Rating and Characteristics—14mm Devices
Varistor
Voltage
V@1.0mA
Part
Number
ROV14E201K
ROV14E221K
ROV14E241K
ROV14E271K
ROV14E301K
ROV14E331K
ROV14E361K
DC
(V)
200
220
240
270
300
330
360
Tolerance
±10%
±10%
±10%
±10%
±10%
±10%
±10%
Maximum
Allowance
Voltage
AC
DC
(V
RMS
)
(V)
130
140
150
175
195
210
230
170
180
200
225
250
275
300
Maximum
Clamping
Voltage
V@50A
(V)
340
360
395
455
505
550
595
Maximum
Surge Current
Rated
Energy
(8x20µs)
Waltage (10x1000µs)
1 Time
2 Times
(A)
(A)
(W)
(J)
6500
6500
6500
6500
6500
6500
6500
6000
6000
6000
6000
6000
6000
6000
0.6
0.6
0.6
0.6
0.6
0.6
0.6
84.0
93.0
101.0
113.0
126.0
138.0
151.0
Capacitance
(Typical)
(pF)
840
710
770
—
—
—
—
qqv
n
qqv
n
qqv
n
––––
––––
––––
––––
Certification
†
Table V15 - Rating and Characteristics—20mm Devices
Varistor
Voltage
V@1.0mA
Part
Number
ROV20E201K
ROV20E221K
ROV20E241K
ROV20E271K
ROV20E301K
ROV20E331K
ROV20E361K
DC
(V)
200
220
240
270
300
330
360
Tolerance
±10%
±10%
±10%
±10%
±10%
±10%
±10%
Maximum
Allowance
Voltage
AC
DC
(V
RMS
)
(V)
130
140
150
175
195
210
230
170
180
200
225
250
275
300
Maximum
Clamping
Voltage
V@50A
(V)
340
360
395
455
505
550
595
Maximum
Surge Current
Rated
Energy
(8x20µs)
Waltage (10x1000µs)
1 Time
2 Times
(A)
(A)
(W)
(J)
12500
12500
12500
12500
12500
12500
12500
10000
10000
10000
10000
10000
10000
10000
1.0
1.0
1.0
1.0
1.0
1.0
1.0
168.0
186.0
202.0
227.0
252.0
277.0
302.0
Capacitance
(Typical)
(pF)
2250
2050
1870
—
—
—
—
qqv
n
qqv
n
qqv
n
––––
––––
––––
––––
Certification
†
†
Certification
Standard
Title
Symbols
File Number
UL1414
‡
Across-the-Line
Components
x
E223034
UL1449 (2nd Edition)
‡
Transient Voltage
Surge Suppressors
q
E223033
CSA
Accessories and Parts
for Electronic Equipment
v
220978
VDE
Varistors for Use in
Electronic Equipment
s
40006997
‡
For UL 1449 (2nd Edition), the maximum clamping voltage is measured at 500A.
Mechanical and Environmental Tests
Humidity
The part is subjected to 40±2˚C, 90 to 95% R.H. for 1000 hours without load and then stored at room temperature and ambient humidity for
1 to 2 hours. The change of VB, (∆VB), is then measured and must meet the requirement of
∆VB/VB≤±
5%, where VB is the initial value.
Impulse Life
The maximum surge current (8 x 20µs) listed in this catalog is applied 1000 times continuously with an interval of 30 seconds at room
temperature. The change of VB, (∆VB), is then measured and must meet the requirement of
∆VB/VB≤±
10%, where VB is the initial value.
Low Temperature Storage
The part is subjected to –40±2°C without load for 1000 hours and then stored at room temperature and ambient humidity for 1 to 2 hours.
The change of VB, (∆VB), is then measured and must meet the requirement of
∆VB/VB≤±
5%, where VB is the initial value.
High Temperature Load
After the Maximum Allowable Voltage is applied at 85±2°C for 1000 hours, the part is stored at room temperature and ambient humidity for
1 to 2 hours. The change of VB, (∆VB), is then measured and must meet the requirement of
∆VB/VB≤±10%,
where VB is the initial value.
High Temperature Storage
The part is subjected to 125±2°C for 1000 hours in a drying oven without load and then stored at room temperature and ambient humidity for
1 to 2 hours. The change of VB, (∆VB), is then measured and must meet the requirement of
∆VB/VB≤±5%,
where VB is the initial value.
60