Analog Circuit, 1 Func
CategoryAnalog mixed-signal IC    The signal circuit   
File Size177KB,8 Pages
ManufacturerMicropac
Websitehttp://www.micropac.com
Download Datasheet Parametric View All

MPC-53503-500-05-AS Overview

Analog Circuit, 1 Func

MPC-53503-500-05-AS Parametric

Parameter NameAttribute value
MakerMicropac
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesANALOG CIRCUIT
JESD-30 codeR-XDFM-P18
Number of functions1
Number of terminals18
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Certification statusNot Qualified
Maximum supply voltage (Vsup)5.5 V
Minimum supply voltage (Vsup)3 V
Nominal supply voltage (Vsup)5 V
surface mountNO
Temperature levelMILITARY
Terminal formPIN/PEG
Terminal locationDUAL
53503
LATCHING, ISOLATED OUTPUT SOLID
STATE POWER CONTROLLERS
Mii
MICROCIRCUITS DIVISION
Features:
Switch Status Output
I
2
T circuit protection with status output
SPST, normally open
5A, 10A and 15A Operating Current
Power FET output with Low on-state resistance
Full military temperature operation:
-55ºC to +125ºC.
Radiation hardened capable.
Military environmental screening available
DESCRIPTION
Applications:
Designed for 24V, 150V and 270V bus
applications
Aircraft Power Distribution
Military/High Reliability Systems
Satellite/Space Systems
The 53503 Solid-State Power Controllers are lightweight, resistant to damage from shock and vibration, and immune to
contact-related problems (contamination, arcing) associated with mechanical equivalents.
Transformer coupling between the input, output and Power Bus stages provides effective isolation of 1000 V RMS. The
Power FET output eliminates bipolar offset and minimizes output voltage drop.
The Control input is CMOS or TTL logic compatible and may operate from a bias supply of 4.5 to 5.5VDC. (See Figure 1)
Integral short-circuit protection, I
2
T trip and output status is provided. The output current flow is continuously monitored and
responds to an over-current condition with an I
2
T trip curve by opening the output. Over-current conditions include Over-
Load and Shorted Output during Turn-On. An open-collector Fault Status or Output Status (optional) is available to indicate
the fault or switch state. The output remains blocked until the short is removed and the unit reset. This feature prevents
damage to the controller while averting further system failures that may be caused by the short circuit. Standard Output
Fault is an Active Low output remaining high (open) under all operating conditions except during an Output Fault. The
optional Output Status is High when the output is On and Low when the output is Off. Resetting the unit is accomplished by
recycling the input control.
This device is available in various quality levels from COTS to class K including any custom screening requirements. All
components have radiation-hardened equivalents. The basic data sheet part is environmentally screened to H level in
accordance with Table C-IX of MIL-PRF-38534 with no element evaluation or QCI.
ABSOLUTE MAXIMUM RATINGS
1
Isolation voltage .......................................................................................................................................................1000 V RMS
2
Continuous operating output voltage ................................................................................................100, 200, 400 or 500 VDC
3
Transient output voltage …………………………………………………………………. .....................100, 200, 400 or 500 VDC
Load Current ..................................................................................Less Than 8 Times Rated Operating Current / Self Limiting
Bias supply voltage, V
DD
....................................................................................................................................... -.6 to 5.5 VDC
Power Bias supply voltage ............................................................................................................................................400 VDC
Control Voltage ................................................................................................................. 1 Volt above V
DD
/ Volt below Return
Operating temperature ............................................................................................................................ -55ºC to +125ºC Case
Storage temperature ..........................................................................................................................................-55ºC to +125ºC
Notes:
1
2
3
60 Hz sine wave
Reversing polarity on the output may cause permanent damage
Device rating. Application derating not included in these values
Micropac Industries
cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac
reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. MICROCIRCUITS PRODUCTS DIVISION
905 E. Walnut St., Garland, TX 75040
(972) 272-3571
Fax (972) 494-2281
E-MAIL:
microsales@micropac.com
12/29/05 Rev G
www.micropac.com
Pg. 1 of 8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号