EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

2N5088TRA

Description
Small Signal Bipolar Transistor, 30V V(BR)CEO, 1-Element, NPN, Silicon, TO-92,
CategoryDiscrete semiconductor    The transistor   
File Size406KB,6 Pages
ManufacturerCentral Semiconductor
Download Datasheet Parametric View All

2N5088TRA Overview

Small Signal Bipolar Transistor, 30V V(BR)CEO, 1-Element, NPN, Silicon, TO-92,

2N5088TRA Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Code_compli
Other featuresLOW NOISE
Collector-based maximum capacity4 pF
Collector-emitter maximum voltage30 V
ConfigurationSINGLE
Minimum DC current gain (hFE)300
JEDEC-95 codeTO-92
JESD-30 codeO-PBCY-T3
JESD-609 codee0
Number of components1
Number of terminals3
Package body materialPLASTIC/EPOXY
Package shapeROUND
Package formCYLINDRICAL
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Polarity/channel typeNPN
Certification statusNot Qualified
surface mountNO
Terminal surfaceTIN LEAD
Terminal formTHROUGH-HOLE
Terminal locationBOTTOM
Maximum time at peak reflow temperatureNOT SPECIFIED
Transistor component materialsSILICON
Nominal transition frequency (fT)50 MHz
VCEsat-Max0.5 V
Base Number Matches1
Selling Zedboard Zynq7020 development board
[i=s]This post was last edited by fjjjnk1234 on 2020-10-18 11:30[/i]Zedboard development board, compatible with the official Zedboard Chip model: Zynq-7020-CLG 484-2I Condition: 95% new or above Acces...
fjjjnk1234 Buy&Sell
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as running...
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as an op amp circuit...
QWE4562009 Integrated technical exchanges
12V to 3.3V 15A, which chips are better?
Generally, for 12V12V to 3.3V 15A, should I convert it to 5V first and then to 3.3V, or should I convert it directly to 3.3V?...
guazhuaq Power technology
How to set the prohibited routing area when AD wiring
I am using AD18. Where is the prohibited routing area set when routing? It appears every time I start routing, such as the area around the pad indicated by the arrow in the figure below. Thank you....
yyz1988 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号