EEWORLDEEWORLDEEWORLD

Part Number

Search

6-1393243-8

Description
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size528KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

6-1393243-8 Overview

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), THROUGH HOLE-STRAIGHT MOUNT

6-1393243-8 Parametric

Parameter NameAttribute value
Maximum operating temperature70 Cel
Minimum operating temperature-40 Cel
Processing package descriptionROHS COMPLIANT
Lead-freeYes
EU RoHS regulationsYes
stateACTIVE
sealRT2
Coil power400 mW
Relay actionTransient
Relay functionDouble Knife Double Throw
Coil resistance1440 ohm
Electrical life30000 Cycle(s)
terminal coatingNOT SPECIFIED
Manufacturer Series1393243
Maximum DC coil current0.0170 A
Maximum DC coil voltage24 V
Maximum AC contact current8 A
Maximum AC contact voltage400 V
DC coil operating voltage16.8 V
DC coil release voltage2.4 V
width12.7 mm
high15.7 mm
length or diameter29 mm
Installation featuresThrough hole installation
operating hours10 ms
Relay typePOWER/SIGNAL RELAY
release time5 ms
Terminal typewelding
General Purpose Relays
PCB Relays
Power PCB Relay RT2
n
n
n
n
n
n
SCHRACK
2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
DC or AC coil
5kV/10mm coil-contact, reinforced insulation
Ambient temperature up to 85°C
WG version: product in accordance to IEC60335-1
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
F0149-C
VZb
Contact Data
(continued)
Mechanical endurance
DC coil
DC coil, reflow version
AC coil
AC coil, reflow version
>30x10
6
operations
>10x10
6
operations
>5x10
6
operations
>2x10
6
operations
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data
Contact arrangement
2 form C (CO) or 2 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A, UL: 10A
Limiting continuous current
8A, UL: 10A
Limiting making current, max. 4s, duty factor 10% 15A
Breaking capacity max.
2000VA
Contact material
AgNi 90/10, AgNi 90/10 gold plated,
AgSnO
2
Frequency of operation, with/without load
DC coil
360/72000h
-1
AC coil
360/36000h
-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/10ms
Electrical endurance
see electrical endurance graph
1)
Contact ratings
Type
Contact
IEC 61810
RT424 DC coil C (CO)
RT444 AC coil A (NO)
RT424 AC coil C (CO)
UL 508
RT424 DC coil A/B (NO/NC)
RT424 DC coil A/B (NO/NC)
RT424 DC coil A/B (NO/NC)
EN60947-5-1
RTE24 DC coil A/B (NO/NC)
RTE24 DC coil A/B (NO/NC)
RTE24 DC coil A/B (NO/NC)
EN60730-1
RT424 DC coil A/B (NO/NC)
Load
8A, 250VAC, cosφ=1, 85°C
8A, 250VAC, cosφ=1, 70°C
8A, 250VAC, cosφ=1, 70°C
10A, 250VAC, gen. purpose, 85°C
1/2hp, 240VAC, 85°C
Pilot duty, B300, R300, 85°C
AC15, 250VAC, 3A
DC13, 24VDC, 2A
DC13, 250VDC, 0.2A
6(2)A, 250VAC, 85°C
Cycles
10x10
3
50x10
3
30x10
3
20x10
3
1x10
3
6x10
3
6.050
6.050
6.050
100x10
3
Coil Data
Coil voltage range, DC coil/AC coil
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.5
006
6
4.2
009
9
6.3
012
12
8.4
024
24
16.8
048
48
33.6
060
60
42.0
110
110
77.0
Coil versions, AC coil 50Hz
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
524
24
18.0
615
115
86.3
620
120
90.0
700
200
150.0
730
230
172.5
5 to 110VDC / 24 to 230VAC
2
class F
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
6.0
11.0
Coil
resistance
Ω±10%
2)
62
90
200
360
1440
5520
8570
2)
28800
2)
Rated coil
power
mW
403
400
400
400
400
417
420
420
2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient
temperature +23°C. Other coil voltages on request.
Release
voltage
VAC
3.6
17.3
18.0
30.0
34.5
Coil
resistance
Ω±15%
3)
350
3)
8100
8800
24350
32500
Rated coil
power
VA
0.76
0.76
0.75
0.76
0.74
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient
temperature +23°C, 50Hz. Other coil voltages on request.
05-2011, Rev. 0511
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Regarding DDR4's winding length, all you need to know is in this book
Author: Xiao Yongchao, member of YiBo Technology Expressway For the design of DDR4, I believe that the engineers have experienced thousands of projects and must be very handy, and they should have the...
yvonneGan PCB Design
EEWORLD University ---- Amplifier Protection Series
Amplifier Protection Series:https://training.eeworld.com.cn/course/5648...
hi5 Automotive Electronics
Introduction to calling DSP functions of TMS320F28335
The first function is: CFFT_f32_sincostable(cfft) Among them, cfft is one of the above structures. The function of this function is to calculate the conversion factor of Fourier transform. From the fo...
fish001 DSP and ARM Processors
Running Debian system on K510 (unsuccessful compilation)
Suddenly I saw in the Makefile fileI guess it is possible to use make to generate a debian image that can run on K510. Try to use the make debian command, which fails as expected, becauseTipsThen type...
tobot Domestic Chip Exchange
UWB transceiver DW1000 chip internal diagram
[i=s]This post was last edited by dcexpert on 2021-4-16 08:49[/i]Click on the image to view high-resolution image...
dcexpert DIY/Open Source Hardware
If the input signal travels 100 meters, is it better to connect it to the positive pole or the negative pole of the optocoupler?
If the IN1 wiring length is 100 meters, is it better to connect IN1 like this, with the negative pole for 100 meters, or is it better to pull the 12V positive pole for 100 meters? I'm just curious, I ...
sky999 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号