ULTRAFAST WIDEBAND HIGH-FREQUENCY LOGARITHMIC AMPLIFIERS
MODEL: MLIF SERIES
FEATURES
•
•
•
•
•
•
•
70 dB dynamic range at 1 GHz
Improved sensitivity
Rise time up to 1 ns
Fast recovery time
±1.5 dB video flatness over 500 MHz bandwidth
Low output noise for increased accuracy
Improved sensitivity through low noise
figure input stages
OPTIONS
• Customized center frequencies and
frequency agility
• Dynamic range and operational bandwidth
• Custom packaging
• Extended environmental limits
• Military screening available
CENTER
FREQUENCY
(MHz)
500
750
900
1000
1000
1500
1800
OPERATIONAL
BANDWIDTH
(MHz)
100
500
100
500
500
500
200
DYNAMIC
RANGE
(dBm)
-70
-65
-70
-60
-70
-60
-65
to
to
to
to
to
to
to
0
0
+5
0
+5
0
+5
TANGENTIAL
SENSITIVITY
(dBm)
-73
-68
-73
-63
-73
-63
-68
VIDEO
FLATNESS
(±dB)
1
1.5
1
1
2
1.5
1
RISE
TIME
(ns)
5
3
10
3
10
3
10
FALL
TIME
(ns)
15
10
30
10
30
10
30
RECOVERY
TIME
(ns)
25
15
45
15
45
15
45
MODEL
NUMBER
MLIF-500/100-70
MLIF-750/500-65
MLIF-900/100-75
MLIF-1000/500-60
MLIF-1000/500-75
MLIF-1500/500-60
MLIF-1800/200-70
ADDITIONAL SPECIFICATIONS
The above models are available in 'A, B, G, K and M' housings.
Linearity measured at center frequency and 25°C is ±1 dB.
Add ±0.5 dB over operating temperature of -40 to +85°C and ±0.5 dB over operating bandwidth.
Slope is 15 mV/dB at center frequency and 25°C.
Slope variations of ±5% will occur over operating temperature of -40 to +85°C.
An additional ±5% variation will occur over operating bandwidth.
Video output is DC coupled and rated into 93
Ω.
DC offset drift over operating temperature of -40 to +85°C is ±50 mV typical.
Input impedance is 50
Ω
(VSWR < 1.5:1 typical).
Improved second-harmonic rejection on limited IF out.
Power: +12 VDC at 400 mA typical, -12 VDC at 75 mA typical.
ORDER OPTIONS
For ±15 VDC, add suffix “C”.
For limited IF output at 0 dBm nominal, (VSWR < 2.0:1 typical) add suffix “L”.
Typical part number: MLIF-1000/500-75BCL (for 'B' housing at ±15 VDC with limited IF output).
NOTE: FOR MODIFICATION OF OUR STANDARD MODELS, PLEASE CONSULT FACTORY.
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-17B/7 08-14-07
MLIF SERIES TYPICAL TEST DATA
LOG LINEARITY
(MLIF-1000/500-70)
PULSE RESPONSE
(MLIF-1000/300-60)
MLIF SERIES OUTLINE DRAWINGS
OUTLINE A
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-17B/8 08-14-07
MLIF SERIES OUTLINE DRAWINGS
OUTLINE B
OUTLINE G*
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
* ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL).
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-17B/9 08-14-07
MLIF SERIES OUTLINE DRAWINGS
OUTLINE K*
OUTLINE M
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
* ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL).
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-17B/10 08-14-07