DATA SHEET
ABC40 SERIES 40W AC/DC
40 W convection cooled
-20 to 50 deg C full load operation
90-264 VAC input
2” x 4 “ x 1.2” (101.6 x 50.8 x 30.48 mm)
No minimum load required - single output models
Conducted EMI EN 55022-B, FCC Part 15 Level B
ITE Safety Agency Approvals
RoHS Compliant
No load power < 0.3 W
FEATURES
APPLICATIONS
Lighting
Industrial Processing
Applied Computing
Instrumentation
Automation Control
Robotics
Wireless Communications
Test and Measurement
BCD.00281_AA_September-18-2013
1
www.power-one.com
DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
Input voltage range
Input frequency range
Input surge current
Safety ground leakage current
Input current:
DESCRIPTION/CONDITION
Universal Input
47 to 400 Hz
230 Vac (cold start)
230 Vac
120 Vac @ 40 W
230 Vac @ 40 W
90 - 264 Vac
Note 3
60 A max.
1000 μA max
0.85 A rms
0.45 A rms
Output
PARAMETER
Voltage Adjustment
Transient Response
Over Voltage Protection
Short Circuit Protection
Remote Sense
Efficiency
Set Point Tolerance
Rise Time
DESCRIPTION/CONDITION
V1
Main output 50 to 100% load change, 50/60
Hz, 50% duty cycle, 0.1A / uSec
130% Typical
130% Typical
V1
>85%
V1: ± 3%, V2 & V3: ± 5%
< 100 mSec
± 10%
< 10%, recovery time < 5 mS
V1 only
0.5 Vdc compensation
Ordering Information
PRODUCT
FAMILY
ABC40-1005G
ABC40-1012G
ABC40-1015G
ABC40-1024G
ABC40-1048G
ABC40-3000G
VOLTS
(VDC)
5.1
12
15
24
48
5.2
12.5
-12.8
5.2
OUTPUT CURRENT
MAX (A)
8.0
3.5
2.7
1.7
0.83
6.0
2.0
0.5
6.0
1.0
0.5
6.0
1.5
0.5
6.0
3.0
0.5
MINIMUM
LOAD (A)
(4)
0
0
0
0
0
0.5
0.1
0.0
0.5
0.1
0.0
0.5
0.1
0.0
1.0
0.1
0.0
RIPPLE &
NOISE
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
TOTAL
REGULATION
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
OVP THRESHOLD
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
ABC40-3001G
23.8
-12.8
5.2
130% Typical
ABC40-3002G
14.6
-14.8
3.3
130% Typical
ABC40-3003G
5.2
-12.8
ABC40 Series
2
www.power-one.com
DATA SHEET
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Maximum outputs for each output. Max power rating should not be exceeded.
Output noise measurement is made with a 20 MHz bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum
capacitor in parallel with a 0.1 uF ceramic capacitor.
Safety Approved: 47 to 63 Hz.
Minimum load specified to meet cross regulation.
Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
Ripple and Noise may be 3% at initial start-up at -20 C.
Specifications subject to change without notice.
Warranty 2 years.
General Specifications
PARAMETER
Hold Up Time
MTBF
Switching Frequency
Isolation Voltage
Weight
DESCRIPTION/CONDITION
6 mSec
>100 khrs
67 kHz Typical
Input to Output: Min 4242 Vdc
150 g (0.33 lbs)
120 / 230 Vac input
MIL-HDBK-217F
Input to Ground: Min 2120 Vdc
Environmental
PARAMETER
Operating Temperature
Humidity
Altitude
Conducted Emissions:
Harmonic current correction:
Radiated Emissions
Static Discharge
Conducted immunity:
DESCRIPTION/CONDITION
Operating
Storage
95%
Operating 10,000 ft.
EN55022, FCC part 15- B
EN61000-3-2, Class A
EN55011-B, FCC part 15-B
EN61000-4-2 Level 3
EN61000-4-6
-20 to 70° C. See derating chart below.
-40 to +85° C.
Non Condensing
Non-operating 40,000 ft
To be controlled in end system
2, 3, 4, 5 Level 3
Safety
PARAMETER
EN / UL / CSA
DESCRIPTION/CONDITION
EN60950-1+A12:2011, IEC60950-1 2
nd
+A1 2009, CSA-22.2 No 60950-01-07+ A1,
UL60950-1-2011
BCD.00281_AA_September-18-2013
3
www.power-one.com
DATA SHEET
Figure 1 Output Power Vs. Temperature
Figure 2 Dimension Drawing (Top and Side View)
Mechanical
INPUT = J1
Pin 1: AC Neutral
Pin 2: AC Line
Mating Connector:
Molex: 09-50-3031
Pins: 08-50-0106
EARTHING TAB = J4
Molex: 19705-4301
Mating Connector:
Molex: 190030001
DC OUTPUT = J2
Pin 1 = V1
Pin 2 = V1
Pin 3 = RTN
Pin 4 = RTN
Pin 5 = V3
Pin 6 = V2
REMOTE SENSE= J3
Pin 1 = +V1 Sense
Pin 2 = -V1 Sense
Mating Connector:
Molex: 22-01-2021
Mating Connector:
Tyco: 647402-6; Pins: 3-647409
Copyright © 2010 Power-One Inc. All rights reserved. Words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the
trademarks and service marks of Power-One Inc. in the U.S. and other countries. All other product or service names are the property of their respective holders.
Power-One products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Power-One reserves the
right to make changes to any products and services at any time without notice. Power-One assumes no responsibility or liability arising out of the application or use
of any information, product, or service described herein except as expressly agreed to in writing by Power-One Inc.
NUCLEAR AND MEDICAL APPLICATIONS
- Power-One products are not designed, intended for use in, or authorized for use as critical components in life sup-
port systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS
- The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufac-
tured. Specifications are subject to change without notice.
ABC40 Series
4
www.power-one.com