T1, T2, Actuator shown with B2 bushing, subtract 0.09 (2.29) for B5 bushing, subtract 0.04 (1.02) for B5 bushing, add 0.09 (2.29)
Std for M2 terminal sub 0.016 (0.04) for M2 terminals sub. 016 (0.04) for M6.
Bushing Options
B2 NON-THD
B5 THD
Termination Options
M2
Double Pole
M6, SPDT
SPDT
P. C. Mounting
www.element14.com
www.farnell.com
www.newark.com
Page <3>
06/06/11 V1.1
Toggle Switches
Sub-Miniature
M6, DPDT
DPDT
P. C. Mounting
Panel Mounting
10-48 Bushing
1/4 In. Bushing
Without Locking Ring
Without Std. Locking Ring
Without Locking Ring
Without Std. Locking Ring
Hardware
Locking Ring
www.element14.com
www.farnell.com
www.newark.com
Page <4>
06/06/11 V1.1
Toggle Switches
Sub-Miniature
Contact Material Options
Contact Plating
R
Gold
Terminal Plating
R = Gold
Ratings
0.4 Volt - Amperes (VA) maximum at 20 V maximum (AC or DC)
Soldering Process:
Manual soldering
Wave soldering
: Use soldering iron of 30 watts, controlled at 350°C approximately 5 s while applying solder.
: Recommended soldering temperature : 260 ±5°C.
: Duration of solder immersion
: Maximum 5 s (PCB is 1.6 mm in thickness).
Soldering : Vapour phase
Important Notice :
This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)