DC/DC Converters
THL 3WI(SM) Series, 3 Watt
Scheme
IEC 60950-1
Features
◆
Compact design in SMD or DIP package
◆
Ultra wide 4:1 input voltage range
◆
Fully regulated outputs
◆
I/O isolation 1500 VDC
◆
SMD version qualfied for leadfree re
flow solder process, MSL 2a
CB
226037
◆
◆
◆
◆
Operating temp. range –40°C to +85°C
Short circuit protection
Remote On/Off control
Input filter to meet EN 55022, class A
without external components
◆
3-year product warranty
The THL 3WI(SM) series is a family of compact 3 W dc/dc-converters with 4:1 input
voltage ranges. The product is available in SMD- or DIP-package. The internal filter
which meets EN55022 Class A without external components makes the converter
easy to design in.
They come with remote On/Off and short circuit protection. THL 3WI(SM) converter
is an excellent solution for data- and telecom applications and for instrumentation
and Industrial electronics.
Models
Order code
DIP models
THL 3-2410WI
THL 3-2411WI
THL 3-2412WI
THL 3-2413WI
THL 3-2415WI
THL 3-2421WI
THL 3-2422WI
THL 3-2423WI
THL 3-4810WI
THL 3-4811WI
THL 3-4812WI
THL 3-4813WI
THL 3-4815WI
THL 3-4821WI
THL 3-4822WI
THL 3-4823WI
Order code
SMD models
THL 3-2410WISM
THL 3-2411WISM
THL 3-2412WISM
THL 3-2413WISM
THL 3-2415WISM
THL 3-2421WISM
THL 3-2422WISM
THL 3-2423WISM
THL 3-4810WISM
THL 3-4811WISM
THL 3-4812WISM
THL 3-4813WISM
THL 3-4815WISM
THL 3-4821WISM
THL 3-4822WISM
THL 3-4823WISM
18 – 75 VDC
(48 VDC nominal)
9 – 36 VDC
(24 VDC nominal)
Input voltage range
Output voltage
3.3 VDC
5.0 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5.0 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
Output current
max.
600 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
600 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
Efficiency typ.
75 %
78 %
80 %
80 %
80 %
77 %
80 %
80 %
75 %
78 %
80 %
80 %
80 %
77 %
80 %
80 %
http://www.tracopower.com
Page 1 of 3
DC/DC Converters
THL 3WI(SM) Series
Input Specifications
Input current at no load
(nominal input voltage)
Input current at full load
(nominal input voltage)
24 Vin models:
30 mA typ.
48 Vin models:
20 mA typ.
24 Vin; 3.3 VDC model:
24 Vin other models:
48 Vin; 3.3 VDC model:
48 Vin other models:
110 mA typ.
160 mA typ.
55 mA typ.
80 mA typ.
3 Watt
Surge voltage
(1 sec. max.)
Conducted noise
Recommended input fuse
(slow blow)
24 Vin models:
50 V max.
48 Vin models:
100 V max.
EN 55022 level A, FCC part 15, level A without
external components
24 V models:
1500 mA
48 V models:
800 mA
±2 % max
– Input variation Vin min. to Vin max.
– Load variation 15 – 100 %
1.0 % max.
1.0 % max.
15 % of rated max current
(operation at lower
load condition is safe but a higher output ripple
will be experienced)
±0.02 %/K
60 mVp-p typ.
300 µs typ.
indefinite, automatic recovery
3.3 & 5 VDC models:
220 µF max.
all other models:
47 µF max.
– Operating (natural convection cooling 20 LFM)
– Storage
– Case
–40°C to +85°C
–40°C to +125°C
+105°C max.
Output Specifications
Voltage set accuracy
Regulation
Minimum load
Temperature coefficient
Ripple and noise
(20 MHz bandwidth)
Transient response setting time
(25 % load step change)
Short circuit protection
Capacitive load
General Specifications
Temperature
Load derating
(natural convection cooling 20 LFM)
DIP models:
2.5 %/K above +65°C
SMD 3.3 & 5.0 VDC models:
2.2 %/K above +55°C
SMD other models:
2.5 %/K above +60°C
95 %
>300‘000 h
1’500 VDC
500 pF max.
>1 GOhm
IEC 60950-1, UL 60950-1
www.tracopower.com/products/thl3wi-cb.pdf
www.tracopower.com/products/thl3wi-csa.pdf
350 kHz
5‘000 m max.
(16‘400 ft)
approved
Humidity
(non condensing)
Reliability, calculated MTBF
(MIL-HDBK-217F, at +25°C, ground benign)
Isolation voltage
(60 sec.)
Isolation capacitance
Isolation resistance
Safety approvals
Switching frequency
Altitude during operation
Remote On/Off
– On:
– Off:
– Off stand by input current
– Reach
– RoHS
– Input/Output
– Input/Output
– Input/Output (500 VDC)
– CB test certificate according IEC 60950-1
– CSA certificate for UL/cUL 60950-1
Safety standard
(designed to meet)
2.5 to 5.5 VDC or open circuit
–0.7 to 0.8 VDC
5 mA max.
www.tracopower.com/products/thl3wi-reach.pdf
RoHS directive 2011/65/EU
Environmental compliance
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
DC/DC Converters
THL 3WI(SM) Series
Pysical Specifications
Casing material
Package weight
Environmental compliance
– Reach
– RoHS
non-conductive plastic
(UL94V-0 rated)
DIP models:
5.4 g
(0.19 oz)
SMD models:
4.2 g
(0.14 oz)
regulation EC 1907/2006
directive 2011/65/EU
max. 265°C / 10 sec.
(wave soldering)
as per
J-STD-020D.01
(to find at:
www.jedec.org
- free registration required)
level 2a as per
J-STD-033B.01
(to find at:
www.jedec.org
- free registration required)
www.tracopower.com
/
products
/
thl3wism
-pack.pdf
3 Watt
Soldering profile for DIP-package models
Lead-free reflow solder process for SMD-package models
Moisture sensivity level
(for SMD-package models)
Packaging
Application note:
www.tracopower.com/products/thl3wi-application.pdf
www.tracopower.com/products/thl3wism-application.pdf
Outline Dimensions
DIP-Models
(0.12)
3.0
2.54
(0.1)
16
1
2
12.70
(0.5)
23.8
(0.94)
bottom view
(0.02)
0.5
Pin-Out
7
8
2.54
(0.1)
10
9
Pin
1
2
7
8
9
10
16
Single
–Vin (GND)
Remote On/Off
ntc.
ntc.
+Vout
–Vout
+Vin (Vcc)
ntc. = not to connect
Dual
–Vin (GND)
Remote On/Off
ntc.
Common
+Vout
–Vout
+Vin (Vcc)
0.5
(0.02)
1.77
(0.07)
10.16
(0.4)
13.7
(0.54)
4.1
(0.16)
8.0
(0.31)
SMD-Models
10 9
8
24.0
(0.94)
top view
7
1.0
(0.04)
2
12.70
(0.50)
(0.12) (0.10)
0.25
(0.01)
13.7
(0.54)
18.1
(0.71)
3.11 2.54
16
1
(0.10)
2.54
8.0
(0.31)
Specifications can be changed any time without notice.
Dimensions in [mm], () = Inch
Tolerances: ±0.25 (±0.01)
Pin pich tolerances: ±0.13 (±0.005)
Rev. 08/12
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · info@traco.ch · www.tracopower.com
Page 3 of 3