over-voltage protection, short circuit protection,
output over-current protection
Operating temperature range: -40℃ to +85℃
Meet CISPR22/EN55022 CLASS A
A2S (wring mounting) and A4S (TS35 rail mounting)
products featuring anti-reverse connection for
input
Meet UL60950 , EN60950 and IEC60950
International standard pin-out
CB
Patent Protection
RoHS
URA_YMD-10WR3 & URB_YMD-10WR3 series are isolated 10W DC-DC products with 4:1 input voltage. They feature efficiency up to 88%,
1500VDC isolation, operating temperature of -40℃~+85℃, input under-voltage protection, output over-voltage, over-current, short circuit
protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in industrial control, electric power, instruments and
communication fields. And extension package A2S and A4S also enable them with reverse voltage protection.
Selection Guide
Certification
Part No.
①
Input Voltage (VDC)
Nominal
(Range)
Max.
②
URA2405YMD-10WR3
URA2409YMD-10WR3
URA2412YMD-10WR3
URA2415YMD-10WR3
URA2424YMD-10WR3
URB2403YMD-10WR3
URB2405YMD-10WR3
URB2409YMD-10WR3
URB2412YMD-10WR3
UL/CE/CB
URB2415YMD-10WR3
URB2424YMD-10WR3
URA4805YMD-10WR3
URA4812YMD-10WR3
URA4815YMD-10WR3
URA4824YMD-10WR3
URB4803YMD-10WR3
URB4805YMD-10WR3
URB4812YMD-10WR3
URB4815YMD-10WR3
URB4824YMD-10WR3
48
(18-75)
80
24
(9-36)
40
Output
Output Voltage Output Current (mA)
(Max./Min.)
(VDC)
±5
±1000/0
±9
±12
±15
±24
3.3
5
9
12
15
24
±5
±12
±15
±24
3.3
5
12
15
24
±555/0
±416/0
±333/0
±208/0
2400/0
2000/0
1111/0
833/0
667/0
416/0
±1000/0
±416/0
±333/0
±208/0
2400/0
2000/0
833/0
667/0
416/0
Efficiency (% Max. Capacitive
④
,Min./Typ.)
Load (µF)
@ Full Load
81/83
1000
84/86
85/87
85/87
85/87
77/79
81/83
84/86
85/87
85/87
86/88
81/83
85/87
85/87
85/87
77/79
81/83
85/87
85/87
86/88
680
470
330
100
2200
2200
680
470
330
100
1000
470
330
100
2200
2200
470
330
100
③
Notes:
①Part
No. with suffix of “A2S” means chassis mounting and suffix of “A4S” means DIN-Rail mounting (e.g. URB2405YMD-10WR3A2S means chassis mounting;
URB2405YMD-10WR3A4S means DIN-Rail mounting);
②Absolute
maximum rating without damage on the converter, but it isn't recommended;
③Efficiency
is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
④
The capacitive loads of positive and negative outputs are identical.
2015.09.28-A/3
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_YMD-10WR3 & URB_YMD-10WR3 Series
Input Specifications
Item
Input Current (full load / no-load)
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
Input under-voltage Protection
Starting Time
Input Filter
Hot Plug
Module switch on
Ctrl
*
Module switch off
Input current when switched off
Note: *The voltage of Ctrl pin is relative to input pin GND.
Operating Conditions
24VDC input
48VDC input
24VDC input
48VDC input
24VDC input
48VDC input
24VDC input
48VDC input
24VDC input
48VDC input
①
Min.
--
--
--
--
-0.7
-0.7
--
--
5.5
14
--
Typ.
502/5
251/4
40
30
--
--
--
--
6.5
15.5
10
Pi filter
Max.
514/12
257/8
--
--
50
100
9
18
--
--
--
Unit
mA
VDC
VDC
ms
Nominal input& constant resistance load
Unavailable
Ctrl suspended or connected to TTL high level (3.5-12VDC)
Ctrl pin connected to GND or low level (0-1.2VDC)
--
6
10
mA
Output Specifications
Item
Output Voltage Accuracy
①
Operating Conditions
0%-100% load
Dual output, balanced load
Full load, the input voltage is
from low voltage to high voltage
②
Min.
--
--
Positive output
Negative output
Positive output
Negative output
--
--
--
--
--
--
--
--
--
110
110
Typ.
±1
±0.5
±0.2
±0.5
±0.5
±0.5
--
300
±3
--
40
--
140
Max.
±3
±1.5
±0.5
±1
±1
±1.5
±5
500
±5
±0.03
80
160
190
Unit
Balance of Output Voltage
Line Regulation
Load Regulation
%
5%-100% load
Cross Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Drift Coefficient
Ripple & Noise
③
Dual output, main circuit with 50% load,
auxiliary circuit with 10%-100% load
25% load step change
Full load
20MHz bandwidth, 5%-100% load
Input voltage range
µs
%
%/℃
mV p-p
%Vo
%Io
Over-voltage Protection
Over-current Protection
Short circuit Protection
Continuous, self-recovery
Note:
①At
0%~5% load, the Max. output voltage accuracy of
±5VDC/±9VDC
output converter is
±5%.
②When
testing from 0% to100%load working conditions,load regulation index of
±5%;
③0%-5%
load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
General Specifications
Item
Insulation Voltage
Insulation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Storage Humidity
Lead Temperature
Non-condensing
Welding spot is 1.5mm away from the casing, 10 seconds
Operating Conditions
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
see Fig. 1
Min.
1500
1000
--
-40
-55
5
--
Typ.
--
--
1000
--
--
--
--
Max.
--
--
--
+85
+125
95
+300
Unit
VDC
MΩ
pF
℃
%RH
℃
2015.09.28-A/3
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_YMD-10WR3 & URB_YMD-10WR3 Series
Vibration
Switching Frequency
MTBF
PWM mode
MIL-HDBK-217F@25℃
--
1000
10-55Hz, 10G, 30 Min. along X, Y and Z
350
--
--
--
KHz
K hours
Note:*This series of products with reduced frequency technology,The switching frequency of the full test, when the load is light, the switching frequency decline.