EEWORLDEEWORLDEEWORLD

Part Number

Search

KA53/127BEV1MWT

Description
Board Connector, 53 Contact(s), 2 Row(s), Male, Wire Wrap Terminal, Receptacle,
CategoryThe connector    The connector   
File Size4MB,19 Pages
ManufacturerHypertronics Corporation
Download Datasheet Parametric View All

KA53/127BEV1MWT Overview

Board Connector, 53 Contact(s), 2 Row(s), Male, Wire Wrap Terminal, Receptacle,

KA53/127BEV1MWT Parametric

Parameter NameAttribute value
MakerHypertronics Corporation
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-55302
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationGOLD (10) OVER NICKEL
Contact completed and terminatedGOLD (10) OVER NICKEL
Contact point genderMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
Number of rows loaded2
OptionsGENERAL PURPOSE
Termination typeWIRE WRAP
Total number of contacts53
KA Series 2 & 3 Row
MIL-DTL-55302 QPL'D
2 and 3 Row Printed Circuit
Board Connectors
17, 29, 33, 41, 53, 62, 65, 72, 80.1, 84, 96, 98, 120,
126, 160 and 160.4 Contacts
• 2 and 3 row printed circuit board connectors
• Provide applications flexibility not available with other
MIL-DTL-55302 connectors
• Over 2,500 models can be constructed with
available components
• 0.100 [2.54] on center (adjacent rows offset by
0.050 [1.27] to allow straight printed circuit traces)
• Straight dip, right angle solder, crimp, solder cup
and Wire Wrap
®
terminations
• 0.024 [0.60] diameter pins/sockets rated at
4 Amps
• Average insertion/extraction force of 1 ounce
per contact
• Contacts removable from wiring side (front release,
rear removable)
• Front release, front removable option available on
receptacle with 160 contacts
• Alignment and keying provided by the end guides –
36 combinations (user changeable)
• Male or female contacts and guides available in either
plug or receptacle
Number of
Contacts
A
± 0.020 [0.50]
17
1.508
[38.30]
1.200
[30.48]
29
2.106
[53.50]
1.801
[45.75]
33
2.307
[58.60]
2.000
[50.80]
41
2.709
[68.80]
2.401
[60.98]
53
3.307
[84.00]
3.000
[76.20]
65
3.909
[99.30]
3.600
[91.44]
General Specifications
Number Contacts
Contact Diameter
Current Rating
Contact Resistance
Extraction Force
Contact Life Cycles
Breakdown Voltage
Between Contacts
Dielectric
Withstanding Voltage
Insulation Resistance
Temperature Rating
Insulator
Contact
Material
Plating
Guide Hardware
Material
Plating
Plating Reference
Male Pins
Female Socket
17, 29, 33, 41, 53, 62, 65, 72, 80.1, 84, 96, 98, 120, 126, 160, 160.4
0.024 [0.60]
4 Amps at 30° C rise
< 5 milliohms
0.30 – 2.00 oz. per contact
100,000
> 1600V RMS
1200V RMS
> 10
6
Megohms at 500 VDC
-55° C to 125° C
Diallyl-phthalate
Beryllium copper wires and brass body
Gold over nickel
Brass / Stainless steel
Nickel / Passivated
T = 10µin gold (min) over nickel
TH = 50µin gold (min) over nickel
TAH = 50µin gold (min) over nickel on mating surface,
5µin gold over nickel on termination
B
Connector Dimension
17 to 65 Contacts
Plug
Receptacle
NOTES:
1) Mated length 0.622 [15.80] unless otherwise specified.
2) Tolerance ± 0.02 [0.50].
3) Wire Wrap is a trademark of Gardner Denver.
Dimensions are in inches [mm]
www.hypertronics.com
3 / 49
What kind of activities do you hope the RF/Radio Frequency section will carry out? Please leave a message in the thread.
The liveliness of a section, in addition to the operator's dedication, is also inseparable from the participation of netizens! We sincerely invite you to give us your opinions on the RF section.What k...
okhxyyo RF/Wirelessly
Oscilloscope usage tips you don't know
Oscilloscope is an effective tool used by engineers almost every day. Its importance is beyond doubt. Especially with the application of new devices, the development of new technologies, and the intro...
EE大学堂 Training Edition
Free Trial | Keysight Accelerates Signal Integrity and Power Integrity Testing
When you design, you need to find and solve signal integrity and power integrity issues early to avoid costly redesigns later. It is often difficult to diagnose and troubleshoot intermittent failures ...
EEWORLD社区 Test/Measurement
Learning PLC technology is super easy
This book focuses on the commonly used basic PLC instructions (bit logic instructions, timers, counters), sequential control instructions, functional instructions (transfer instructions, comparison in...
arui1999 Download Centre
Advantages of modules
Qorvo and X-Microwave collaborate to bring modular building blocksQorvo and X-Microwave have teamed up to bring modular building blocks to RF and microwave engineers for evaluating components in proto...
btty038 RF/Wirelessly
EEWORLD University Hall----Live Replay: What to listen to when stuck in traffic? New generation of in-car audio systems and software-defined cars
Live replay: What to listen to when stuck in traffic? New generation in-car audio system and software-defined car : https://training.eeworld.com.cn/course/6045...
hi5 Integrated technical exchanges

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号