ILLS-G0100-5-003 Overview

Submersible Tank Gauging Level Transmitter

ILLS series
Submersible Tank Gauging Level Transmitter
Piezo-resistive sensor
Stainless steel housing and diaphragm
Accuracy <0.5% FS BFSL
Various outputs including Volts and mA.
Pressure ranges from 1mWG to 10mWG
Options available on the ILLS transmitter.
Pressure range
Voltage or current output
Cable length
Suitable applications
Static tank level
Container or chamber level
Vehicle tank level
IBC, IBC Tote or Pallet Tank
Rainwater harvesting
The ILLS is designed for use in continuous
submersion in liquids such as water, oils
and fuels in small tanks, where
conventional mechanical level switches
and sensors are not ideal and more level
‘control’ and measurement is required.
The probe uses a piezo-resistive silicon
sensing technology, isolated from the
media by a diaphragm within the stainless
steel housing It offers excellent stability,
repeatability and resolution for
applications where a small tank level is
required, from as low as 1m through to 10
m high tanks.
Each device is temperature compensated,
calibrated and supplied with a traceable
serial number and calibration certificate.
Performance
Accuracy (Non-Linearity & Hysteresis)
<±0.5% / FS (BFSL)
Setting Errors (offsets)
2-wire
3-wire
2-wire
3-wire
Supply
Load
Zero & Full Scale, <±0.5% / FS
Zero & Full Scale, <±0.5% / FS
R
max
= [(Supply-9min)/0.02]
W
R
min
= 10k
W
<0.005% FS / 1V
0.05% FSO / kW
Permissible Load
Influence Effects
Custom versions can be made for particular applications.
Material Specifications
Housing
“O” ring seals
Diaphragm
Cable sheath material
Media wetted parts
Weight
303 Stainless Steel
Viton
316L Stainless Steel
FEP standard
Housing, “O” ring seal, diaphragm, cable
sheath
Transmitter: approx 75g
Cable: 48g per metre
Any, small zero shift when tilted through
90º
6
> 100x 10 cycles
50M
W
@50Vdc
Electrical Protection
Supply reverse polarity
No damage/no function
Electromagnetic compatibility CE Compliant
Mechanical Stability
Shock
Vibration
100g / 11s
10g RMS (20 - 2000Hz)
Temperatures & Thermal Effects
Media Temperature
-20ºC (Non-freezing) to +60ºC
Storage temperature
-20ºC to +70ºC
Compensated temperature range
20ºC±25ºC
Thermal Zero Shift (TZS)
<±0.04% /FS/ºC
Thermal Span Shift (TSS)
<±0.015% /ºC
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
Installation position
Operational life
Insulation resistance
www.cynergy3.com
ISO
9001
CERTIFIED
© 2015 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
[NUCLEO-L552ZE review] + driving LCD19264 display
In order to observe the test results conveniently, I am used to using LCD to display. The code was transplanted from other development boards tested before. According to convention, as long as the pin...
hujj stm32/stm8
GD32103E-EVAL Full-function evaluation board with screen
https://detail.tmall.com/item.htm?spm=a1z10.5-b.w4011-18883888937.65.c8162af80RiU46id=576897750536rn=2113700bcd9e6682e833730a455c6a29abbucket=19skuId=3880525425703This one is 80% new. I replaced the o...
apleilx Buy&Sell
Free application: Infineon's revolutionary photoacoustic spectroscopy (PAS) CO2 sensor, the legend of excessive CO2 leads to lack of attention
When the indoor CO2 concentration exceeds 1000 ppm , the human body will experience symptoms such as drowsiness, shortness of breath, lack of concentration , etc. If the concentration gradually increa...
EEWORLD社区 Sensor
Working principle of two matched transistor pairs
In this picture, what are the changes in the collector voltages of the two transistors? What are the functions of the operational amplifier at the front end and VR10?...
fangfang120 Analog electronics
I can't figure out the op amp formula, can someone help me look at it?
This is the formula in the picture above. What I don't understand is how the VL drawn with a red line is merged into the formula below. Could you please teach me?...
sunboy25 Analog electronics
GD32E231C-START unboxing first time
GD32E231C-START unboxing. After waiting for so long, I finally received the board and sample today. The packaging is very simple.Black text on a white board. Next, you can build the circuit while prog...
蓝雨夜 GD32 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号