The sum of DC voltage and the peak AC voltage must not exceed the rated voltage of the capacitor
Performance
Performance
Capacitance Change
Equivalent Series Resistance
Leakage Current
The following specifications will be satisfied when the capacitor is tested at +20°C:
≤ 160 V
> 160 V
Does not exceed 200% of the initial value
Does not exceed leakage current limit
Within 15% of the initial value
Within 10% of the initial value
Dimensions – Millimeters
Dimensions in inches
Size Code
D2C
D2L
D3C
D3L
D4C
D4L
D5C
D5L
K2C
K2L
K3C
K3L
K4C
K4L
K5C
K5L
D
±0.031
1.375
1.375
1.375
1.375
1.375
1.375
1.375
1.375
2
2
2
2
2
2
2
2
L
±0.062
2.125
2.625
3.125
3.625
4.125
4.625
5.125
5.625
2.125
2.625
3.125
3.625
4.125
4.625
5.125
5.625
LT
±0.039
2.420
2.930
3.440
3.960
4.430
4.940
5.450
5.960
2.420
2.930
3.440
3.960
4.430
4.940
5.410
5.960
S
±0.019
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.875
0.875
0.875
0.875
0.875
0.875
0.875
0.875
V
Nominal
0.315
0.315
0.315
0.315
0.315
0.315
0.315
0.315
0.539
0.539
0.539
0.539
0.539
0.539
0.539
0.539
Mounting
Stud (M x H)
±0.039
M8 x 0.472
M8 x 0.472
M8 x 0.472
M8 x 0.472
M8 x 0.472
M8 x 0.472
M8 x 0.472
M8 x 0.472
M12 x 0.63
M12 x 0.63
M12 x 0.63
M12 x 0.63
M12 x 0.63
M12 x 0.63
M12 x 0.63
M12 x 0.63
Mounting Clip
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V3/H2/UTE2736
V4/UTE2737
V4/UTE2737
V4/UTE2737
V4/UTE2737
V4/UTE2737
V4/UTE2737
V4/UTE2737
V4/UTE2737
Weight
Ounces
2.8
3.3
4
4.6
5.3
5.8
6.5
7.2
5.8
7.1
8.5
9.7
11.1
12.3
13.6
15
Note: Add 0.015 inches to D and 0.045 inches to L for Sleeving
3.5 inch diameter cans available upon request. LT listed is for A-type termination code. Information for other termination codes is available upon request.
Note: Add 0.015 inches to D and 0.045 inches to L for Sleeving
3.5 inch diameter cans available upon request. LT listed is for A-type termination code. Information for other termination codes is available upon request.
1. The practical significance of medical temperature control blanketIn clinical settings, physical cooling and warming are very common treatments. Physical cooling can be used for mild hypothermia the...
In industrial sites, when signals are transmitted between electrical equipment and instruments that are far apart from each other, it is often found that instruments and other equipment interfere with...
A few questions about 4G signal indicators. In what range are these values considered good signal quality? In addition, some experts suggested that we just read the ECL value, 0 is the best and 2 is t...
Position: Power supply hardware engineer
Responsibilities:1. Develop power hardware solutions based on the company's chip products, such as LED driver power supply, DCDC isolation power supply, etc.2....
[i=s]This post was last edited by jinglixixi on 2022-5-18 11:00[/i]Project BackgroundThe environment is an important living condition that affects us, so it is very necessary to detect its status. The...