2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
4. Allow suitable slack on leads when wiring, and do not subject the
terminals to excessive force.
Max. Solder Time
Weight
11/20/2014
AZ2505
AZ
RELAY ORDERING DATA
Nominal Coil
VDC
5
6
9
12
24
COIL SPECIFICATIONS -Single Coil
Set Voltage Reset Voltage Max. Continuous
VDC
VDC
VDC[1]
3.75
4.0
6.5
4.50
4.8
7.8
6.75
7.2
11.7
9.00
9.6
15.6
18.00
19.2
31.2
Coil Resistance
± 10%
25
36
81
144
576
ORDER NUMBER
1 Form A
AZ2505P1–1A–5D
AZ2505P1–1A–6D
AZ2505P1–1A–9D
AZ2505P1–1A–12D
AZ2505P1–1A–24D
1 Form B
AZ2505P1–1B–5D
AZ2505P1–1B–6D
AZ2505P1–1B–9D
AZ2505P1–1B–12D
AZ2505P1–1B–24D
Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination Suffix as seen in Chart below. Note[1]: Max continuous voltage
should not be applied for more than 30 seconds.
COIL SPECIFICATIONS -Dual Coil
Nominal Coil
VDC
5
6
9
12
24
Set Voltage Reset Voltage Max. Continuous
VDC
VDC
VDC[1]
3.75
4.0
6.5
4.50
4.8
7.8
6.75
7.2
11.7
9.00
9.6
15.6
18.00
19.2
31.2
Coil Resistance
± 10%
12.5 + 12.5
18 + 18
40.5 + 40.5
72 + 72
288 + 288
ORDER NUMBER
1 Form A
AZ2505P2–1A–5D
AZ2505P2–1A–6D
AZ2505P2–1A–9D
AZ2505P2–1A–12D
AZ2505P2–1A–24D
1 Form B
AZ2505P2–1B–5D
AZ2505P2–1B–6D
AZ2505P2–1B–9D
AZ2505P2–1B–12D
AZ2505P2–1B–24D
Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination suffix as seen in chart below. Note[1]: Max continuous voltage
should not be applied for more than 30 seconds.
TERMINATION OPTIONS
MS
MH
MC
WHS
WHH
CH
Stationary Contact: Shunt
Stationary Contact: Shunt
Stationary Contact: Shunt
Stationary Contact: Tab
Stationary Contact: Tab
Stationary Contact: Tab
Moveable Contact: Lead Wire
Moveable Contact: Tab
Moveable Contact: Shunt
Moveable Contact: Lead Wire
Moveable Contact: Tab
Moveable Contact: Shunt
WSS
WSH
CS
*
PCB
Stationary Contact: Lead Wire
Stationary Contact: Lead Wire
Stationary Contact: Lead Wire
Printed Circuit Board
Moveable Contact: Lead Wire
Moveable Contact: Tab
Moveable Contact: Shunt
Tin Plated Terminals
*
Only available in 60A, 80A,
and 100A
version
MECHANICAL DATA
Single Coil
Termination Type MS
Dual Coil
11/20/2014
AZ2505
Single Coil
Termination Type MH
Dual Coil
Single Coil
Termination Type WSS
Dual Coil
Load Current
60A
80A
100A
120A
Tab Thickness(T)
1.0mm
1.5mm
2.0mm
2.5mm
11/20/2014
Dual
Coil
Termination Type
PCB
Wiring Diagram
pin 1
5
6
pin 1
pin 3
5
6
pin 2
pin 3
NOTE:
1. Single Coil Latching Version
(1). After energizing Pin 3(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected.
(2). After energizing Pin 1(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected.
1. Double Coil Latching Version
(1). After energizing Pin 2(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected.
(2). After energizing Pin 2(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected.