3.3V LOW EMI SMD SPREAD SPECTRUM CLOCK OSCILLATOR
ASSV SERIES
*RoHS COMPLIANT
7.0 x 5.0 x 1.8mm
| | | | | | | | | | | | | | |
FEATURES:
• Integrated spread spectrum technology
• EMI reduction up to 20dB
• Solve EMI failures as a drop in replacement for std. 5x7mm Osc.
• Cost effective EMI reduction
APPLICATIONS:
• Printers, Digital Copy Machines, Scanners, Projectors,
Modems, LAN, WAN, Navigation Equipment, Automotive,
Audio, Medical Electronics, Hand-held readers,
Industrial Automation
STANDARD SPECIFICATIONS:
PARAMETERS
Frequency Range
Spread Type
EMI Reduction
Operating Temperature
Storage Temperature
Frequency Stability
Supply Voltage (Vdd)
Start-up Time
Stabilization Time
Rise and Fall Time (Tr/Tf)
Load
Current Consumption
Duty Cycle
Output Logic
Cycle to cycle Jitter
Output Impedance
Static Discharge Voltage
Aging
Output Voltage “High”; “1”
Output Voltage “Low”; “0”
Modulation Carrier Freq.
Pin 1 Function
5.000 MHz to 160.000 MHz
±0.5 (see table 1 for options)
-9dBc min. 100MHz at C0.5; -15dBc min. 100MHz at C1.5
With respect to the dB level when no modulation.
0°C to + 70°C (see options)
- 65°C to + 150°C
± 100 ppm (see options)
3.3 Vdc ± 5%
2ms typ, 5ms max.
2ms max.
4n sec. max. (10% VDD <-> 90% VDD)
15pF
20mA max.
50% ± 5% (CL = 15pF at 50% VDD)
CMOS Square wave
±250ps typ; ±300ps max.
40Ω
>2,000V (per MIL-STD-883, method 3015)
±5ppm per year max.; Ta=+25°C
2.0V min.; 3.2V typ (at 90% VDD)
0.8V max. ; 0.2V typ (at 10% VDD)
6.9KHz min.; 55.5KHz max; Freq dependent call for details.
Output is high impedance when taken low.
Output enable/disable time: 100 ns max.
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
rev1.1-4/06
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
3.3V LOW EMI SMD SPREAD SPECTRUM CLOCK OSCILLATOR
ASSV SERIES
MARKING:
- TUH
- ASSV ZYX
(Frequency)
(Part Number; (Date code, Y=year, W=week) (eg. 0603= third week of 2006)
ZY : Date Code
Z = Month (A to L)
Y = Year (6 for 2006)
X = Traceability
Note 1:
TUH : Frequency
T= First " ten " digit of frequency
U = First " unit " of frequency
H = First " tenth " of frequency
Example: 100 for 10.0 MHz
143 for 14.31818 MHz
Table 1
Spread types and %
Down Spread
D1
-1%
D3
-3%
Center Spread
C0.5
±0.5%
C1.5
±1.5%
* Standard
*RoHS COMPLIANT
7.0 x 5.0 x 1.8mm
| | | | | | | | | | | | | | |
*
OPTIONS AND PART IDENTIFICATION (Left blank if standard):
ASSV - Frequency - Operating Temperature - Frequency Stability - Spread type - Packaging
Temperature options:
-
D
for 40°C to +85°C
Frequency stability option:
-
W
for 25 ppm max
-
Z
for 50 ppm max
Packaging option:
-
T
for Tape and Reel
OUTLINE DRAWING:
PIN
1
2
3
4
FUNCTION
Tri-state
GND
Output
Input
Dimensions: inch (mm)
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
rev1.1-4/06
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com