Series AM5TW-RVZ
5 Watt | DC-DC Converter
FEATURES:
•
Wide Input Range (4:1)
•
24 Pin DIP Package
•
Metal package
•
High efficiency up to 82%
•
•
•
•
Operating temperature -40
o
C to + 85
o
C
Input / Output isolation 1500 VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
Models
Single output
Model
AM5TW-2403S-RVZ
AM5TW-2405S-RVZ
AM5TW-2412S-RVZ
AM5TW-2415S-RVZ
AM5TW-4803S-RVZ
AM5TW-4805S-RVZ
AM5TW-4812S-RVZ
AM5TW-4815S-RVZ
Input Voltage
(V)
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
Output Voltage
(V)
3.3
5
12
15
3.3
5
12
15
Output Current
max (mA)
1200
1000
416
333
1200
1000
416
333
Capacitive load,
max (μF)
2200
1000
470
330
2200
1000
470
330
Efficiency
(%)
70
73
74
74
68
73
74
76
Models
Dual output
Model
AM5TW-2405D-RVZ
AM5TW-2412D-RVZ
AM5TW-2415D-RVZ
AM5TW-4805D-RVZ
AM5TW-4812D-RVZ
AM5TW-4815D-RVZ
Input Voltage
(V)
9-36
9-36
9-36
18-72
18-72
18-72
Output Voltage
(V)
±5
±12
±15
±5
±12
±15
Output Current
max (mA)
±500
±208
±166
±500
±208
±166
Capacitive load,
max (μF)
±470
±100
±68
±470
±100
±68
Efficiency
(%)
77
82
82
72
75
75
Input Specifications
Parameters
Voltage Range
Filter
Start up time
Peak Input Voltage time
Absolute Max Rating
Nominal
24
48
Typical
9-36
18-72
π
(Pi) Network
Maximum
Units
VDC
Ms
Ms
VDC
24 Vin
20
15
-0.7-40
Isolation Specifications
Tested I/O voltage
Resistance
Capacitance
Parameters
Conditions
3 sec
Typical
> 1000
60
Rated
1500
VDC
MOhm
pF
Units
Output Specifications
Voltage Balance
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R13.B
Parameters
Balanced Load
Conditions
Typical
±1
±1
Continuous
Auto Recovery
Maximum
Units
%
%
At 20MHz Bandwidth
±0.5
±0.5
±0.02
60
%
%
%/
o
C
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Tel: +1 514 620 2722
1 of 3
Series AM5TW-RVZ
5 Watt | DC-DC Converter
Units
KHz
o
C
o
C
o
C
General Specifications
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
Parameters
100% load
Full Load (see derating chart)
Conditions
Typical
100-400
-40 to +85
-40 to +125
Maximum
95
%
Nickel coated copper
15
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25
o
C)
Free air convection
100
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
2
3
9
11
14
16
22
23
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
Single
1500 VDC
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Dual
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5TW-RVZ
Dimensions
31.75
(1.25)
0.50
(0.02)
5 Watt | DC-DC Converter
22.86
(0.90)
20.32
(0.80)
Bottom View
23 22
2.54
(0.10)
16
14
5.08
(0.20)
Printed Face
Built-in Stand-offs to
ease PCB cleaning
10.16
(0.40)
Derating
Free Air Convection
85 º C
100
Output Power %
80
60
40
20
0
-40
0
25
50
75
85
100
Safe Operating Area
Ambient Temperature
º C
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
3.05
(0.12)
Tel: +1 514 620 2722
3 of 3
15.24
(0.60)
2
3
9
11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only