IEC Inlet Filters
A range of compact IEC 60320 inlet power entry modules combining
VDU’s, vending machines and many other general purpose
1 or 2 fuse holders for US and IEC fuses. Plus a unipolar or bipolar
rocker switch.
•
Current ratings from 1A to 6A
•
Integral single or twin fuse holder
•
Unipolar or bipolar rocker switch
•
Snap-in or screw mount versions
•
Medical versions available
Mechanical Specifications
applications.
Designed for use in business, consumer and medical equipment,
With fuse holders and mains switch
F.MA-F.MB-F.MC-F.MD
series
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
fuses 5 x 20 mm (IEC) or 6.3 x 32 mm (US),
unipolar (F.MA-F.MB) or bipolar (F.MC-F.MD)
rocker switch;
1 (F.MA-F.MC) or 2 (F.MB-FMD) fuse holders for
Code
(example pt no. - F.MA.01A.01.07.FA)
F.MB. 03A. 05.– –.– –
F.MA.
01A. 04.– –.– –
07.– –.– –
03.– –.– –
01.– –.– –
02.– –.– –
(A)
3
1
l
R
L
2 x 10
(mH)
Filter Range
Cx
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
output terminals;
ground terminal connected to case.
faston 6.3 x 0.5 mm or 2.8 x 0.5 mm for filter
faston 2.8 x 0.5 mm for fuse terminals;
faston 4.8 x 0.8 mm for rocker switch terminals;
F.MD.
F.MC.
06A. 06.– –.– –
09.– –.– –
08.– –.– –
Climatic category:
Rocker switches:
Rated current (I
R
):
Voltage test (2
S
.):
Electrical Specifications
Leakage current (I
L
):
at 220 V, 50 Hz, max value
line to line 1700 Vdc
HPF (25/085/21);
50000 on-off operations;
Rated voltage (V
R
):
max 250 V, 50/60 Hz
referred to room temperature = 40°C
line to ground 3000 Vdc or 1800 Vac
A = Filter output terminals 2.8 x 0.5 mm
C = Filter output terminals 6.3 x 0.8 mm
F = Snap-in mounting
G = Screw mounting
07 = Fuse 5 x 20 mm
14 = Fuse 6.3 x 32 mm
A = 1 Fuse + unipolar rocker switch
B = 2 Fuses + unipolar rocker switch
C = 1 Fuse + bipolar rocker switch
D = 2 Fuses + bipolar rocker switch
6
2x1
2 x 2.5 0.047
0.047
(µF)
0.047
2 x 2500
2 x 2500
(pF)
Cy
2 x 2500
2 x 0.23
I
L
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.002
(mA)
1
(M )
1
R
1
Temperature range: -25°C to +85°C
6(4)A / 250 Vac (Rated current),
10(4)A / 250 Vac (Rated current),
10000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
26
Approvals