Integrated Circuit Systems, Inc. • 525 Race Street • San Jose • CA • 95126 • (408)295-9800tel • www.icst.com
MDS1415A
ICRO
C
LOCK
Pin Assignment
ICLK
VDD
GND
33.0M
1
2
3
4
8
7
6
5
14.318M
PD
VDD
GND
MK1415
ESS Notebook Sound Clock Source
MK1415
Pin Descriptions
1
2
3
4
5
6
7
8
ICLK
VDD
GND
33.0M
GND
VDD
PD
14.3M
I
P
P
O
P
P
I
O
Input CLOCK. Connect to a 14.31818 MHz clock.
Connect to +3.3V or +5V.
Connect to ground.
33.00 MHz clock output.
Connect to ground.
Connect to +3.3V or +5V. Connect to pin 2.
Power Down. Active low. Both output clocks stop low.
14.31818 MHz buffered clock output.
Key: I = Input, O = output, P = power supply connection
External Components/Crystal Selection
A minimum number of external components are required for proper operation. A decoupling capacitor of
0.1µF should be connected between VDD and GND on pins 2 and 3, and a 33Ω terminating resistor
should be used on each clock output if the trace is longer than 1 inch.
2
Revision 1237
Printed 10/15/99
Integrated Circuit Systems, Inc. • 525 Race Street • San Jose • CA • 95126 • (408)295-9800tel • www.icst.com
MDS1415A
ICRO
C
LOCK
Electrical Specifications
Parameter
Supply Voltage, VDD
Inputs
Clock Outputs
Ambient Operating Temperature
Soldering Temperature
Storage temperature
Operating Voltage, VDD
Input High Voltage, VIH, input clock only
Input Low Voltage, VIL, input clock only
Input High Voltage, VIH
Input Low Voltage, VIL
Output High Voltage, VOH
Output High Voltage, VOH
Output Low Voltage, VOL
Operating Supply Current, IDD, 5.0V
Operating Supply Current, IDD, 3.3V
Power Down Supply Current, IDDPD, 5V
Input Capacitance
Input Clock
Power up time, from power down to clocks stable
Input Clock Duty Cycle
Output Clock Rise Time
Output Clock Fall Time
Output Clock Duty Cycle
Absolute Maximum Clock Period Jitter
One Sigma Clock Period Jitter
MK1415
ESS Notebook Sound Clock Source
Minimum
Typical
Maximum
7
VDD+.5V
VDD+.5V
70
260
150
5.5
2.5
2.5
1.5
0.8
Units
V
V
V
°C
°C
°C
V
V
V
V
V
V
V
V
mA
mA
µA
pF
MHz
ms
%
ns
ns
%
ps
ps
Conditions
Referenced to GND
Referenced to GND
Referenced to GND
Max of 10 seconds
ABSOLUTE MAXIMUM RATINGS (note 1)
-0.5
-0.5
0
-65
3.0
3.5
2
IOH=-4mA
IOH=-25mA
IOL=25mA
No Load
No Load
No Load
PD pin
VDD-0.4
2.4
0.4
14
8
10
7
14.31818
4
20
DC CHARACTERISTICS (at 5.0V unless otherwise noted)
AC CHARACTERISTICS (at 5.0V unless otherwise noted)
PD low to high
Time above 2.5V
0.8 to 2.0V
2.0 to 0.8V
Time above 1.5V
Variation from mean
10
80
1.5
1.5
55
45
50
130
40
Notes:
1. Stresses beyond those listed under Absolute Maximum Ratings could cause permanent damage to the device. Prolonged exposure
to levels above the operating limits but below the Absolute Maximums may affect device reliability.
2. Typical values are at 25°C.
3
Revision 1237
Printed 10/15/99
Integrated Circuit Systems, Inc. • 525 Race Street • San Jose • CA • 95126 • (408)295-9800tel • www.icst.com
MDS1415A
ICRO
C
LOCK
Package Outline and Package Dimensions
8 pin SOIC
MK1415
ESS Notebook Sound Clock Source
E
Pin 1
H
D
Q
e
b
c
h x 45°
A
Symbol
A
b
D
E
H
e
h
Q
Inches
Min
Max
0.055 0.061
0.013 0.019
0.185 0.200
0.150 0.160
0.225 0.245
.050 BSC
0.015
0.004
0.01
Millimeters
Min
Max
1.397 1.5494
0.330
0.483
4.699
5.080
3.810
4.064
5.715
6.223
1.27 BSC
0.381
0.102
0.254
Ordering Information
Part/Order Number
MK1415S
MK1415STR
Marking
MK1415S
MK1415S
Package
8 pin SOIC
Add tape and reel
Temperature
0-70°C
0-70°C
While the information presented herein has been checked for both accuracy and reliability, MicroClock Incorporated assumes no responsibility for either its use or for the
infringement of any patents or other rights of third parties, which would result from its use. No other circuits, patents, or licenses are implied. This product is intended for use in
normal commercial applications. Any other applications such as those requiring extended temperature range, high reliability, or other extraordinary environmental requirements
are not recommended without additional processing by MicroClock. MicroClock reserves the right to change any circuitry or specifications without notice. MicroClock does not
authorize or warrant any MicroClock product for use in life support devices or critical medical instruments.
4
Revision 1237
Printed 10/15/99
Integrated Circuit Systems, Inc. • 525 Race Street • San Jose • CA • 95126 • (408)295-9800tel • www.icst.com