The reference level for the relative attenuation arel of the TFS 208B is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency
f
N
is fixed at 208 MHz without any tolerance or limit. The values of relative attenuation arel
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Bandwidth
1
dB
arel
… f
N
f
N
f
N
f
N
f
N
… f
N
… f
N
… f
N
+
-
-
+
+
400
28
14
28
242
kHz
MHz
MHz
MHz
MHz
ae
f
N
BW
typ. value
2,2
-
-
dB
tolerance / limit
1,5 …3,5 dB
-
208
MHz
4,9
MHz
800
kHz
Relative attenuation
f
N
f
N
f
N
f
N
f
N
f
N
f
N
f
N
IP3
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
-
-
-
+
+
400
207
28
14
28
kHz
MHz
MHz
MHz
MHz
0,15
57
48
37
45
dB
dB
dB
dB
dB
max.
min.
min.
min.
min.
1
38
30
5
12
dB
dB
dB
dB
dB
Absolute group delay
-
-
400
400
kHz
kHz
+
+
400
400
kHz
*)
kHz
8
ns
max.
30
ns
180
ns
max.
300
ns
Group delay ripple
VSWR
-
400
kHz
+
400
kHz
**)
1,3 : 1
max.
2:1
Intermodulation
min.
max.
OTR
TCf ***)
-
-
- 36
ppm/K
45
10
dB
dBm
- 10 °C ... + 85°C
- 40 °C ... + 125°C
*) measured with smoothing; smoothing aperture
≤
50 kHz
**) modulation signals: f
N
and f
N
+ 14 MHz, each of 10 dBm; measured signal:
***)
∆f(Hz)
= TCf(ppm/K) x (∆T) x fTo(MHz)
f
N
- 14 MHz
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 208b.doc
Version 1.5
05.08.2005
VI
TELEFILTER
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
10
Filter specification
TFS 208B
2/5
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
204
0.25
0.24
0.23
0.22
0.21
0.2
0.19
0.18
0.17
0.16
0.15
212
delay in µs
magnitude in dB
58
106
154
202
250
298
frequency in MHz
346
394
442
490
magnitude in dB
204.8
205.6
206.4
207.2
208
208.8
frequency in MHz
209.6
210.4
211.2
Construction and pin connection
(All dimensions in mm)
9,3 Max.
8
6
7
5,0Max.
9
10
TFS 208B
●
T31
1
2
3
5
4
Date cod e
1,8 Max.
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
2,54 ±0,1
2,54 ±0,12,54 ±0,1
0,10
°
60
1
2
3
10
9
8
7
0,8
7,1
6
2,8
4
5
Date code:
T
U
V
...
Year + week
2005
2006
2007
50
Ω
Test circuit
L1
10
5
L2
SAW
1, 2, 3, 4, 6, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 208b.doc
Version 1.5
05.08.2005
VI
TELEFILTER
Stability characteristics
Filter specification
TFS 208B
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
2. Vibration:
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 +0,3/-0,1
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,30 ± 0,1
Bo
: 9,70 ± 0,1
Ct
: 13,5 ± 0,1
P1
t
Do
PIN Marker
Po
P2
G
Ct
Bo
F
Ko
Date Code
Typ
D1
Ao
W 2
A
C
N
W 1
E
G
W
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 208b.doc
Version 1.5
05.08.2005
VI
TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 208B
4/5
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
30 ... 150 s
Time / s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 208b.doc
Version 1.5
05.08.2005
VI
TELEFILTER
Recommended land dimensions
Filter specification
TFS 208B
5/5
History
Version
1.0
1.1
1.2
1.3
1.4
1.5
Reason of Changes
- generate according to customer requirement specification
- stopband attenuation corrected
- change the high frequency side transition band edge frequency
f0+13,5MHZ f0+14MHz
- change the specification to customer updated specification
version 1.0.0 (16-05-2001)
- change trailer to 300mm
- change packing and mark pin1 of pin connection
- correct recommended land dimensions
Name
Dr. Sabah
Steiner
Steiner
Date
22.11.2000
23.11.2000
30.11.2000
Dr. Sabah
Dr. Sabah
Strehl
30.05.2001
04.07.2001
05.08.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.