FS20-1000-C2-B

Description
Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT
CategoryPower management    transformer   
File Size47KB,1 Pages
ManufacturerTriad Magnetics
Websitehttps://www.triadmagnetics.com/
Environmental Compliance
Download Datasheet Parametric View All

FS20-1000-C2-B Overview

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT

FS20-1000-C2-B Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTriad Magnetics
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Center click function 1NO
Center click function 2NO
high36.5 mm
Insulation voltage4200000 V
length57.15 mm
Installation featuresTHROUGH HOLE MOUNTED
Number of secondary windings2
Output current 11 A
Output current 21 A
Output voltage 110 V
Output voltage 210 V
method of packingBULK
physical sizeL57.15XB47.62XH36.5 (mm)
main ratingDUAL 115V
surface mountNO
Transformer typeSPLIT BOBBIN POWER TRANSFORMER
VA rating20 VA
width47.62 mm

FS20-1000-C2-B Preview

CLASS 2/3 TRANSFORMER
FS20-1000-C2
Description:
The FS20-1000-C2 is a series/parallel primary and dual secondary, split bobbin
design which operates with either a parallel input of 115V or a series input of 230V.
The secondaries are 10V @ 1A each. They can be used independently (up to
300V difference between them) or in series for double the voltage or in parallel for
double the current. The split bobbin design eliminates the need for costly
electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 20.0VA
2. Primary: Series: 230V; Parallel: 115V
3. Secondaries: 10.0V @ 1.0A each
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 4200 VRMS pri to sec
7. Hipot tested 100% at 2160 VRMS sec to sec
8. Recommended fuse (fuse on primary): For 115V - Cooper/Bussman, Type MDL,
rated 500mA, 250V. For 230V – Littlefuse, Type 313, rated 250mA, 250V
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155°C).
E
Agency File:
UL: File E65390, UL 5085-1 & 3 (1585), Class 2 not wet / Class 3 wet Transformer
cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
TUV Certificate No.: R72120839, EN61558, Safety Isolating xfmr, general use
L
H
1
2
3
4
Dimensions:
H
W
1.437
1.875
Weight: 0.80 lbs
L
2.25
A
0.300
B
0.400
C
1.600
Units in inches.
D
0.041
E
0.020
F
0.234
D
F
A
8
Schematic:
PARALLEL
1
115V
50/60Hz
2
3
4
230V
50/60Hz
SERIES
1
2
3
4
4
1
5
10V @ 1A
2
3
6
7
10V @ 1A
8
A
5
B
C
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
1
Note:
Order and shipping documentation may have a “-B” suffix; this indicates Bulk
packaging but does not show on the actual part number marked on the transformer
.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
4
0.06" DIAMETER
HOLE
Board Layout
www.TriadMagnetics.com
Phone: (951) 277-0757
Fax: (951) 277-2757
460 Harley Knox Blvd.
Perris, CA 92571
Publish Date: December 4, 2013

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号