AC Film Capacitors
Motor run
B 32335
Construction
Dielectric: polypropylene film
Aluminum can
Soft polyurethane resin
Features
Self-healing properties
Low dissipation factor
Overpressure disconnector
High insulation resistance
Typical applications
For general sine wave applications,
mainly as motor run capacitor for room air conditioner units
Terminals
Double fast on 6,3 x 0,8 mm and Quadruple fast on 6,3 x 0,8 mm
Mounting parts
Metal stud (max. torque = 5 Nm)
Technical data and specifications
Standard
Rated capacitance
C
N
Tolerance
Rated voltage
U
N
Rated frequency
f
N
Life expectance
Maximum ratings
Maximum permissible voltage
U
max
Maximum permissible current
I
max
Test data
AC test voltage terminal to terminal
U
TT
Insulation voltage terminals to case
Insulation resistance
R
is
or time constant at
τ
20 °C
Rel. Humidity
≤
65 °C (minimum value)
Dissipation factor tanδ at 20 °C
Maximum rate of voltage rises du/dt
max
≤
1,0 x10
-3
(120 Hz)
10 V/µs
2 x U
N
, 60s.
2000 Vac, 60s.
3000 s
1,1 x U
N
1,3 x I
N
(U
n
= Rated voltage)
(I
n
= Rated current)
IEC / EN 60252
15+2 ... 50+8µF
±
5%,
±
6%,
±10%
380 ... 440 Vac
50...60 Hz
30.000 h (class A)
Mains
Fan
Herm
Issue No. 2
07/01
Page 1 of 7
AC Film Capacitors
Motor run
B 32335
Technical data (cont`d)
Climatic data
Climatic category
Lower category
T
min
Upper category
T
max
Damp heat test
t
test
Permitted capacitance
∆C/C
Approved marks
UL810
10000 AFC
25/085/21 according to IEC 60068-1
-25 °C
+85 °C
21 days
≤
3%
Notes
:
1) It should be noted that presence of harmonics produces over voltage & over current on capacitors.
Resonance may cause serious damage to installation if a significant level of total harmonic distortion level
exists for voltage or current. In such cases, series reactors must be considered.
2) Operating temperature class: in accordance with the reference standards, these temperatures are those
measured on the surface on the capacitor.
Issue No. 2
07/01
Page 2 of 7