EEWORLDEEWORLDEEWORLD

Part Number

Search

76030T-23B-32PB

Description
MIL Series Connector, 32 Contact(s), Male, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size59KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

76030T-23B-32PB Overview

MIL Series Connector, 32 Contact(s), Male, Crimp Terminal, Receptacle

76030T-23B-32PB Parametric

Parameter NameAttribute value
MakerHiRel Connectors Inc
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number76030
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typePANEL
OptionsGENERAL PURPOSE
Shell surfaceOLIVE DRAB CADMIUM PLATED
Housing size23
Termination typeCRIMP
Total number of contacts32
MS27505
Rear Panel Box Mount Environment Resisting Receptacle
MIL-DTL-38999
Series I Receptacles
2 PL
S
R
R
CHAMFERED OR
ROUNDED 4 PL
M
L
MAX
.060 [1.52] MAX.
GROMMET EXTENSION
R
ØD
R
ØX
ØP
4 PL
EQUAL WITHIN .015 [0.38]
8 PL
K
SHELL
SIZE
+.001/-.005
9
11
13
15
17
19
21
23
25
ØD
K
.085 [2.16]
.085 [2.16]
.085 [2.16]
.085 [2.16]
.085 [2.16]
.085 [2.16]
.115 [2.92]
.115 [2.92]
.115 [2.92]
L
MAX
.219 [5.56]
.219 [5.56]
.219 [5.56]
.219 [5.56]
.219 [5.56]
.219 [5.56]
.250 [6.35]
.250 [6.35]
.250 [6.35]
M
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.790 [20.07]
.790 [20.07]
.790 [20.07]
ØP
.128 [3.25]
.128 [3.25]
.128 [3.25]
.128 [3.25]
.128 [3.25]
.128 [3.25]
.128 [3.25]
.147 [3.73]
.147 [3.73]
R
.359 [9.13]
S
±.020
[±0.51]
.938 [23.83]
ØX
MAX
.547 [13.89]
.656 [16.66]
.828 [21.03]
.953 [24.21]
+.015/-.000
[+0.03/-0.13] [+0.38/-0.00]
.572 [14.53]
.700 [17.78]
.850 [21.59]
.975 [24.77]
1.100 [27.94]
1.207 [30.66]
1.332 [33.83]
1.457 [37.01]
1.582 [40.18]
+.000/-.005 +.010/-.005
[+0.00/-0.13] [+0.25/-0.13]
.406 [10.31] 1.031 [26.19]
.453 [11.51] 1.125 [28.58]
.484 [12.31] 1.219 [30.96]
.531 [13.49] 1.312 [33.32] 1.078 [26.38]
.578 [14.61] 1.438 [36.53] 1.203 [30.56]
.625 [15.88] 1.562 [39.67] 1.328 [33.73]
.687 [17.46] 1.688 [42.88] 1.453 [36.91]
.750 [19.05] 1.812 [46.02] 1.578 [40.08]
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
A-19
In the EMC-related experiments of circuits, there are some voltage pulse experiments. How should the withstand voltage value of the capacitor be considered?
The figure shows the related voltage pulse experiment. It can be seen that in the 12V system, the highest US reaches -150V. So when we choose the input filter capacitor, should we choose the one with ...
小太阳yy Switching Power Supply Study Group
Start with LoRa and learn more about the Internet of Things
LPWA currently includes a variety of technologies, such as LoRa, Sigfox, Weightless and NB-IoT, among which LoRa has entered China since 2013. It is expected that the shipment volume of Semtech's SX12...
Aguilera RF/Wirelessly
Ask about the udealy function of Liunx
Since udelay is an infinite loop, will the processor interrupt interrupt the udelay function to handle the interrupt, and then handle the high-priority task after the interrupt exits?...
stm32f103vct6 Linux and Android
How to modify the AT32F4xx SRAM space size
Questions: The default SRAM size of AT32F403, AT32F403A, AT32F407 is 96KB, which can be modified to 224KB. The default SRAM size of AT32F413 is 32KB, which can be modified to 16KB or 64KB. How to modi...
宋元浩 MCU
About software testing of commercial appliances
Hello everyone! I would like to learn about the knowledge of software testing for commercial or household appliances: What is the difference between testing of appliance software and commonly known so...
UUC Test/Measurement
EEWORLD University ---- Operating System Harbin Institute of Technology
Operating Systems Harbin Institute of Technology : https://training.eeworld.com.cn/course/5367"Operating System" is an important professional course for computer-related majors. The purpose of studyin...
木犯001号 MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号