HC9 Series
High Current 9 Power Inductors
• Design utilizes high temperature powder iron material
with a non-organic binder to eliminate thermal aging
• Inductance Range from 0.2µH to 47.0µH
• Current Range from 3.65 amps to 95.0 amps
• Frequency Range 1kHz to 500kHz
Applications
• Next generation processors
• High current DC-DC converters
• VRM, multi-phase buck regulator
• PC, workstations, routers, servers
Environmental Data
• Storage temperature range: -40°C to +155°C
• Operating temperature range: -40°C to +155°C
(range is application specific)
• Solder reflow temperature: +260°C max for 10 seconds maximum
Packaging
• Supplied in tape and reel packaging, 450 parts per reel
Description
• 155°C maximum total operating temperature
• Surface mount inductors designed for higher speed switch
mode applications requiring lower inductance, low voltage and
high current
Part
Number
HC9-R20-R
HC9-R47-R
HC9-1R0-R
HC9-1R5-R
HC9-2R2-R
HC9-3R3-R
HC9-4R3-R
HC9-6R8-R
HC9-100-R
HC9-220-R
HC9-330-R
HC9-470-R
Rated
Inductance
µH
0.20
0.47
1.0
1.5
2.2
3.3
4.3
6.8
10.0
22.0
33.0
47.0
OCL
(1)
Nominal
+/-15% µH
0.218
0.544
1.04
1.70
2.53
3.52
4.67
7.45
10.9
22.4
34.5
49.2
Irms
(2)
Amps
(Typ.)
46.7
33.7
23.7
21.0
17.2
14.3
13.0
10.3
8.50
6.30
4.42
3.65
Isat
(3)
Amps
20% rolloff
65
40
28
22
18
15
13.2
11.4
8.6
6.0
4.8
3.9
Isat
(4)
Amps
30% rolloff
95
57
41
32
26
22
19.1
15.1
12.5
8.7
7.0
5.7
DCR (m
Ω
)
max. @
20°C
0.50
0.88
1.87
2.27
3.37
4.87
5.90
9.40
14.0
25.7
48.8
72.3
Volts
(5)
µSec
(VµS)
2.87
4.78
6.70
8.46
10.4
12.4
14.4
18.1
22.0
31.5
37.3
44.8
1) Test Parameters: 100kHz, 1.0Vrms
2) Irms amps for approximately
∆T
of 40°C without core loss.
Derating is necessary for AC currents. Pad layout, trace thickness and width, airflow,
and proximity of other heat generating components will affect the temperature rise. It is
recommended that the temperature of the part not exceed 155°C under worst case
conditions verified in the end application.
3) Peak current for approximately 20% rolloff @20°C
4) Peak current for approximately 30% rolloff @20°C
5) Applied Volt-Time product (V-µS) across the inductor. This value represents the applied V-µS at
operating frequency necessary to generate additional core loss which contributes to the 40°C
temperature rise. De-rating of the Irms is required to prevent excessive temperature rise. The
100% VµS rating is equivalent to a ripple current Ip-p of 20% of Isat (30% rolloff option).
Part number definition:
First 3 characters = Product code and size.
Last 3 characters = Inductance in µH. R = decimal point.
If no R is present third character = # of zeros.
-R suffix = RoHS compliant
1207
BU-SB07346
Page 1 of 3
Data Sheet 4312
Core Loss
North America
Cooper Bussmann
1225 Broken Sound Parkway NW
Suite F
Boca Raton, FL 33487-3533
Tel: 1-561-998-4100
Fax: 1-561-241-6640
Toll Free: 1-888-414-2645
Cooper Bussmann
P.O. Box 14460
St. Louis, MO 63178-4460
Tel: 1-636-394-2877
Fax: 1-636-527-1607
Europe
Cooper Bussmann
Cooper (UK) Limited
Burton-on-the-Wolds
Leicestershire • LE12 5TH UK
Tel: +44 (0) 1509 882 737
Fax: +44 (0) 1509 882 786
Cooper Bussmann
Avda. Santa Eulalia, 290
08223
Terrassa, (Barcelona), Spain
Tel: +34 937 362 812
+34 937 362 813
Fax: +34 937 362 719
Asia Pacific
Cooper Bussmann
1 Jalan Kilang Timor
#06-01 Pacific Tech Centre
Singapore 159303
Tel: +65 278 6151
Fax: +65 270 4160
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice,
to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any
technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the
Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling,
can be reasonably expected to result in significant injury to the user.
© 2007 Cooper Bussmann
S t . L o u i s, M O 6 3 1 7 8
w w w. c o o p e r bu s s m a n n . c o m
1207
BU-SB07346
Page 3 of 3
Data Sheet 4312