EEWORLDEEWORLDEEWORLD

Part Number

Search

5431.8051101

Description
IEC Appliance Inlet C14 Modular Assembling Options
File Size633KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet View All

5431.8051101 Overview

IEC Appliance Inlet C14 Modular Assembling Options

Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
- Alternative: version without line filter Felcom 64
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
References
Weblinks
General Product Information
Approvals
- Line switch with other rocker marking
- VDE License Number: 101307
- UL License Number: E72928
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

EEWORLD University Hall----Design using TI's series capacitor buck converter
Designing with TI's series capacitor buck converter : https://training.eeworld.com.cn/course/4977...
wanglan123 Analog electronics
【Silicon Labs Development Kit Review 07】_freeRtos+UART+TH+IMU+PainterEngine
Hello, everyone. I have been playing with the board peripherals recently. Now I have adjusted all the sensors and am going to transplant PainterEngine to make a UI. The specific configuration is as fo...
jone5 Development Kits Review Area
Live broadcast at 2 pm today [Introduction to TI MSP430 capacitive touch development]
This lecture mainly explains the development of the capacitive touch module (CapTIvate) on MSP430, including the development process description, the principle of capacitive touch, the introduction of...
EEWORLD社区 Microcontroller MCU
Effect of Temperature on Performance and Life of Communication Switching Power Supplies
【Introduction】Our statistical results in practical work confirm that the main cause of data loss, hardware failure and downtime is the failure of the communication switch power supply system. The chan...
木犯001号 Power technology
Comparison of two PWM motor drives
I would like to ask about the PWM motor with two driving modes shown in the above figure. The current motor speed changes greatly with the changes of temperature (+20℃→-30℃) and voltage (DC 12V→10.2V)...
UUC Motor Drive Control(Motor Control)
CircuitPython 6.0.0 Alpha 2 released
From: https://blog.adafruit.com/2020/07/24/ci ... -released/New features and improvements since 6.0.0 Alpha 1API changesDisable socket , wiznet5k and network modules. They will be removed in the netwo...
dcexpert MicroPython Open Source section

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号