FCA-210-AZ8

Description
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.15A (COIL), 12VDC (COIL), 1800mW (COIL), 10A (CONTACT), 28VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size140KB,4 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

FCA-210-AZ8 Overview

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.15A (COIL), 12VDC (COIL), 1800mW (COIL), 10A (CONTACT), 28VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

FCA-210-AZ8 Parametric

Parameter NameAttribute value
Minimum operating temperature-70 Cel
Maximum operating temperature125 Cel
stateActive
Relay typePOWER/SIGNAL RELAY
width13.34 mm
high25.65 mm
length or diameter26.04 mm
Maximum DC coil current0.1500 A
coil_input_supply_typeDC
DC coil operating voltage9 V
coil_power__mw_1800
DC coil release voltage0.7500 V
Coil resistance80 ohm
Maximum DC coil voltage12 V
contact_ac_max_rating_r_load10A@115VAC
Maximum AC contact current10 A
Maximum DC contact current10 A
contact_dc_max_rating_r_load10A@28VDC
contact_output_supply_typeAC/DC
Maximum AC contact voltage115 V
Maximum DC contact voltage28 V
Electrical life100000 Cycle(s)
Manufacturer SeriesFCA-210
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours11 ms
Dimensions26.04mm X 13.34mm X 25.65mm
eference_standardMIL-R-83536
Relay actionMOMENTARY
Relay functionDPDT
release time11 ms
sealHERMETICALLY SEALED
Terminal typeSOLDER
SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
q
HERMETICALLY SEALED
q
ALL WELDED CONSTRUCTION
q
BALANCED FORCE
q
PERMANENT MAGNET DRIVE
q
CONTACTS: SILVER CADMIUM
OXIDE WITH GOLD PLATING
q
COILS FOR DC, 50 TO 400Hz AND 400Hz AC
q
WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS)
The Series FCA-210 relay is a polarized single-side stable design, where the flux from a permanent
magnet provides the armature holding force in the deactivated state, and its flux path is switched
and combined with the coil flux in the operated state. This results in appreciably increased contact
pressure in both states over that of a spring return nonpolar design. We also manufacture other
versions of this relay:
FCA-410:
10 AMPERE 4PDT RELAY
FCA-610:
10 AMPERE 6 PDT RELAY
QP
a
L
fi
A
to MIL-R-8
li ed
Qu
ED
OV
3536
PPR
AVAILABLE
FCA-215:
15 AMPERE DPDT RELAY, HAS THE SAME SPECIFICATIONS AS THE FCA-210
EXCEPT IS RATED AT 15 AMPS.
CONTACT RATING-AMPERES
Ratings Are Continuous Duty
TYPE OF
LOAD
Resistive
Inductive
Motor
Lamp
LIFE (MIN.)
CYCLES X 10
3
100
20
100
100
28 VDC
10
8
4
2
115VAC
400Hz
10
8
4
2
115/200VAC 30
400 Hz 60Hz *
10
8
4
2
2.5
2.5
2.0
1
* 60 Hz LOADS RATED FOR 10,000 OPERATIONS
OVERLOAD CURRENT 40 AMPS DC, 60AMPS 400Hz
RUPTURE CURRENT 50 AMPS DC, 80 AMPS 400Hz
CONTACT MAKE BOUNCE 1 MILLISECOND AT NOMINAL VOLTAGE
MAX. CONTACT DROP AT 10 AMPS: INITIAL 0.100 VOLTS.
END OF LIFE 0.125 VOLTS
8
The best way to teach yourself electronics
[size=4][color=#000000][backcolor=white]What electronic knowledge should electronic beginners focus on? What learning methods should be adopted to learn electronic technology well? [/backcolor][/color...
fish001 Analogue and Mixed Signal
Insufficient DSP memory space
Because the RAM in DSP is mainly used to store data, but when using FFT algorithm, wavelet algorithm, etc., the data volume will be too large and the internal RAM space is not enough. There are two so...
Jacktang Microcontroller MCU
Modal Analysis of NAVECO 2046 Frame
1 Structural modelingThe modeling work was carried out in the UG NX software environment. In order to minimize the scale of solution, all entities on the frame were expressed by sheets, and then impor...
frozenviolet Automotive Electronics
A brief discussion on air gap and leakage inductance
Core saturation is equivalent to an air-core coil on the primary side of the transformer (equivalent to a short circuit). The current will be very large and will continue to rise until the transformer...
木犯001号 Power technology
【GD32L233C-START Review】-3. Successful establishment of Keil development environment and DEMO routine test
The previous evaluation could not be compiled successfully due to the CMSIS core problem in the Keil environment. I tried many new methods but none of them worked. I guess the inability to access fore...
kit7828 GD32 MCU
MSP432 MCU takes advantage of real-time operating systems
Developing on 32-bit ARM systems often requires juggling multiple operations at once—in these situations, a real-time operating system (RTOS) comes in handy. MSP432 MCUs offer compatibility with sever...
Jacktang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号