DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size81KB,3 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LES010ZE9 Overview

DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid

LES010ZE9 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSETPOINT ACCURACY: +/-1%
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage75 V
Minimum input voltage36 V
Nominal input voltage48 V
JESD-30 codeR-XDMA-P4
JESD-609 codee0
Maximum load regulation0.5%
Number of functions1
Output times1
Number of terminals4
Maximum operating temperature100 °C
Minimum operating temperature-40 °C
Maximum output voltage3.333 V
Minimum output voltage3.267 V
Nominal output voltage3.3 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output15 W
Fine-tuning/adjustable outputNO
LES DC-DC Series Data Sheet
Single-Output, 15 Watts
Description
LES dc-dc converters provide up to 15 watts of output
power in an industry-standard package and footprint. With
a maximum case temperature of 100°C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500VDC
isolation, short circuit protection, and six-sided shielding.
The LES is available with optional enable and voltage trim
pins. Please see the IAD Series for dual output
applications.
Features
Industry-standard
package
Industry-standard pinout
100°C case operation
Short-circuit protection
24V and 48V inputs
Input Pi filter and
6-sided shielding
Regulated outputs
1500V isolation
Efficiency vs. Load (24V Input)
85
80
75
EFFICIENCY %
70
65
60
55
50
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
45
10
20
30
40
50
60
70
80
90
100
LOAD %
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
Ovp Trip Range
Ovp Type
±1%
0.2%
Vout
0.5% Vout
10% Iout Rated
25% Iout
2% Vout
500 ms
±10%
Shutdown / Hiccup
110 - 150%
200% Iout
115 -140% Vout Nom.
Second Control Loop
85
80
75
EFFICIENCY %
Efficiency vs. Load (48V Input)
70
65
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
LES010ZE
LES015ZG
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
REV. JUN 04, 2004
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
(Bellcore TR-NWT-000332)
Safety
10 ms
Positive/Negative Logic
400 kHz
1500 VDC
500 VDC
0.02 ppm/°C
-40 To +100°C
-40 To +100°C
95%
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, cUL, TUV
Page 1 of 3
Several difficult concepts to grasp when learning MCU
With the rapid development of electronic technology, computers have deeply penetrated into our lives. Many electronics enthusiasts have begun to learn about single-chip microcomputers, but the content...
rain MCU
Definition of priority order of MSP430 microcontroller interrupts
The interrupts of 430 are defined in the priority order shown in Figure 1 below. There are three types of interrupts: 1. System reset, 2. Non-maskable interrupt (NMI), and 3. Maskable interrupt.Figure...
火辣西米秀 Microcontroller MCU
Discuss power supply and design issues
When designing a power module, should capacitors and inductors be placed nearby or must they be placed at the pins of each application? What are the differences and pros and cons of these two placemen...
史龙飞 PCB Design
Talking about Flyback Converter
1. Let's first learn about the flyback converter. 1. Basic flyback circuit: 400942[/attach]2. Working principle: 51)][font=-apple-system-font, BlinkMacSystemFont, "][size=17px]The polarity of the prim...
木犯001号 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号