Power Entry Modules with Line Filter
https://www.schurter.com /PG06
DD22
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole, for PCB Mounting
Order required accessories separately
C14
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on mounting on PCB , from rear-side
- 4 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 1- or 2-pole , Line filter in standard and medical
version
- V-Lock notch standard
- PCB terminals
Characteristics
-
-
-
-
-
Ultra-compact design. Ideal for low profile designs
All single elements are already wired
For added safety "Extra-Safe" fuse drawers are available
Ideal for application with high transient loads
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Fuse drawer 1-pole, plus spare fuse case
Fuse drawer 2-pole, with shorting bar
Other rocker marking
Line switch, illuminated
Line switch 1-pole
Medical version M80
Protection class II, 70°C
Other versions on request
-
-
-
-
-
-
-
Unique Selling Proposition
-
-
-
-
Most compact power entry module
Attractive flat design
Switch for highest inrush current
V-Lock cord retaining
References
Weblinks
Alternative: version without line filter
DD21
Alternative: Standard version
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 50/60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
For PCB mounting 3 mm additional
quick connect 6.3 x 0.8 mm
Screw-on mounting: max 3 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1
UL 498 CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'000'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
EMC Products
1
DD22
Approvals
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DD22
Approval Logo
Certificates
VDE Approvals
UL Approvals
Certification Body
VDE
UL
Description
Certificate Number: 40001522
UL File Number: E72928
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60320-1
IEC 60939
IEC 60127-6
IEC 61058-1
UL 498
UL 1283
CSA C22.2 no. 42
CSA C22.2 no. 8
Description
Appliance couplers for household and similar general purposes
Passive filters for suppressing electromagnetic interference
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Switches for appliances. Part 1. General requirements
Standard for Attachment Plugs and Receptacles
Electromagnetic interference filters
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Designed for applications acc.
Designed for applications acc.
Standard
IEC/UL 60950
IEC 60601-1
IEC 60335-1
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Safety of electrical appliances for household and similar purposes. Meets
the requirements for appliances in unattended use. This includes the en-
hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Suitable for use in medical equipment according to IEC/UL 60601-1
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
MicrositeV-Lock
SCHURTER AG
Medical Equipment
SCHURTER AG
2
EMC Products