Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole
635
C14
70° C
Description
- Panel Mount:
Snap-in version from front side
- 2 Functions:
Appliance Inlet, Protection class I, Circuit breaker type TA35, 2-pole
- Quick connect terminal 6.3 x 0.8 mm
- Alternative: version for 16 A (20 A) 6136
- Substitute for type 7764
Characteristics
- Unwired
- Switch non-illuminated or illuminated
Thermal overload protection
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
Approvals
- Pre-wired version
- Quick-connect terminals 4.8 x 0.8 mm
- Protection class II, 70°C
- VDE License Number: 40023066
- UL License Number: E96454
References
Weblinks
General Product Information
Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-Stock-
Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 60 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Snap-in1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated.
Conditional short circuit Inc:
2000 A
Circuit Breakers
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Connectors
635
www.schurter.com/pg05
Dimensions
30
10.6
31.8
Power entry modules without line filter
65.4 mm
3.2
27.4
+0.20
0
58.8 x 27.2
65.4
6
max. R 0.2
R3
S
± 0.05
28.4
Diagrams
L
1)
PE
N
N' P
2
1) Line
2) Load
L' P
1
2)
PE'
TA35
Connectors
59
+0.20
0
Power entry modules without line filter
www.schurter.com/pg05
ORDER CODE
Number of switched poles
Number of protected poles
2-pole
1
LINE
635
Table 1 Selection for type TA35
Order example
2
LINE
LOAD
LOAD
TA35-
CBD
W
F
120
C0
Switch
without
illumination
illuminated
240 V
120 V
CBT
CBD
No other
features
Switch
C12
C14
C32
C34
Other versions on request
Colours
Switch front
W
B
3
4
6
black
black
black
black
black
Rocker
non-illuminated
illuminated
white
black
–
–
–
–
–
red transparent
green transparent
orange transparent
Other colours on request
Rocker legend
Surface
F
H
K
L
embossed
printed
printed
printed
Illustration
0
l
Colour of print
OFF OFF
ON
white
black
white
black
ON
l
l
M
printed
Other legends on request
Position of the rocker
legend e.g. F
0
0
Rated current I
n
(A)
I
n
1,0
2,0
4,0
5,0
6,0
Code
J10
J20
040
050
060
I
n
8,0
10,0
12,0
15,0
Code
080
100
120*
150*
Other rated currents on request
*) UL / CSA only
Connectors
3
635
www.schurter.com/pg05
Technical data (continued)
Circuit breaker
Tripping characteristics
I
n
< 3 A
[ min ] [ sec ]
10'000
Type
p
Rated current
Ambient temp.
TA35
<3A (TC-1, TC-2)
+23 °C
Power entry modules without line filter
Tripping characteristics
I
n
> 3 ... 15 A
[ min ] [ sec ]
10'000
Type
Rated current
Ambient temp.
TA35
> 3–15A (TC-1, TC-2)
+23 °C
60
30
20
10
5
200
100
1
50
2`000
1`000
500
60
30
20
10
5
200
100
1
50
2`000
1`000
500
20
10
5
2
1
0,5
Tr ipping time
Tr ipping time
20
10
5
2
1
0,5
0,3
0,2
0,1
1,05 1,35
2
3
4
5
8
10
Multiple of rated current
[ x In ]
0,3
0,2
0,1
1,05 1,35
2
3
4
5
8
10
Multiple of rated current
[ x In ]
The above tripping characteristics apply to symmetrical overloads on the two poles.
At asymmetric overloads on two pole types the tripping current will be increased by factor
1.05
(TC-2).
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for lower or higher ambient temperature,
use a correction factor from the table below.
* Ambient
temperature [°C]
–25
–20
0
+23
+40
+50
+60
Correction factor
0.79
0.81
0.90
1.00
1.03
1.04
1.06
* Temperature must be measured at the rear of the breaker
next to the terminals after equipment operating tempera-
ture has been reached.
Example:
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at +60 °C
ambient temperature:
10 A
+60 °C
1.06
10 A x 1.06 = 10.6 A
Order code (Order example)
Type
Order code TA35
Wiring
1
wired
0
unwired
6135
C B D W F 1 2 0 C 0
see table 1
. 0 2 1 0
Terminals
1
Quick connect 6.3 x 0.8 mm
Mounting
2
Snap-in s = 1.5 mm
3
Snap-in s = 2.0 mm
4
Snap-in s = 2.5 mm
5
Snap-in s = 3.0 mm
0
Protection class 1
Please note that Schurter will establish an
internal part number for logistics use in
addition to the order code. The format of
this internal part number is, for example:
6135.xxxx.xxxx
Packaging unit
40 Pcs
Connectors
Power entry modules without line filter
www.schurter.com/pg05
Accessories
Description
635
Assorted Covers
Rear Cover
0859.0074
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
Appliance Outlet further types to 6135
4787
4788
Connector Overview complete
IEC Connector C15A, Rewireable, Straight
IEC Connector C15A, Rewireable, Straight
IEC Connector C15A, Rewireable, Angled
IEC Connector C13, Rewireable, Angled
IEC Connector C13, Rewireable, Angled
Connector further types to 6135
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13
Power Cord further types to 6135
0311
3011
3012
3013
3020
...
0102
0102-G
0112
4012
4013
...
The specifications, descriptions and illustrations indicated in this document are based on
Connectors
current information. All content is subject to modifications and amendments.
5