PCB Relay
A Power Relay for a Variety of Purposes
with Various Models
I
G2R
I
I
I
I
I
I
I
Conforms to VDE0435 (VDE approval: C250
insulation grade), UL508, CSA22.2, SEV,
SEMKO.
Meets VDE0700 requirements for household
products according to VDE0110.
Clearance and creepage distance: 8 mm/8 m.
Models with CTI250 material available.
High-sensitivity (360 mW) and high-capacity
(16 A) types available.
Double-winding latching type available.
Plug-in with test button and quick-connect
terminals available.
Highly functional socket available.
X
R
C+SE
VDE
Ordering Information
Classification
PCB terminal
General-purpose
Bifurcated contact
High-capacity
High-sensitivity
Double-winding latching
Plug-in terminal
General-purpose
LED indicator
LED indicator with test
button
Diode
LED indicator and diode
LED indicator and diode
with test button
Plug-in terminal
(Bifurcated
crossbar
contact)
General-purpose
LED indicator
LED indicator and diode
DC
AC/DC
DC
Enclosure
ratings
Flux protection
Fully sealed
Flux protection
Fully sealed
Flux protection
Flux protection
Flux protection
Unsealed
AC/DC
AC/DC
DC
DC
Coil
ratings
AC/DC
Contact form
SPST-NO
G2R-1A
G2R-1A4
G2R-1AZ
G2R-1AZ4
G2R-1A-E
G2R-1A-H
G2RK-1A
---
---
---
---
---
---
G2R-1A3-S
G2R-1A3-SN
G2R-1A3-SND
SPDT
G2R-1
G2R-14
G2R-1Z
G2R-1Z4
G2R-1-E
G2R-1-H
G2RK-1
G2R-1-S
G2R-1-SN
G2R-1-SNI
G2R-1-SD
G2R-1-SND
G2R-1-SNDI
G2R-13-S
G2R-13-SN
G2R-13-SND
DPST-NO
G2R-2A
G2R-2A4
---
---
---
G2R-2A-H
G2RK-2A
---
---
---
---
---
---
---
---
---
DPDT
G2R-2
G2R-24
---
---
---
G2R-2-H
G2RK-2
G2R-2-S
G2R-2-SN
G2R-2-SNI
G2R-2-SD
G2R-2-SND
G2R-2-SNDI
---
---
---
Note:
1. When ordering, add the rated coil voltage to the model number.
Example: G2R-1A 12 VDC
Rated coil voltage
2. OMRON has also prepared the above relays with AgSnIn contacts, which are more tolerant of large inrush currents and
physical movement compared with relays with standard contacts. When ordering, add "-ASI" to the model number.
Example: G2R-1A-ASI
3. Standard, NO contact type relays are TV-3 class products in accordance with the TV standards of the UL/CSA. Models with
AgSnIn contacts are TV-5 class products.
Example: G2R-1A-ASI
When ordering a TV-8 class model, insert "-TV8" into the model number as follows:
Example: G2R-1A-TV8-ASI
4. Models with CTI250 material are also available.
Contact your OMRON representative for more details.
1
G2R
Model Number Legend
G2R
G2R
1
-
2
3 4 5
-
6 7 8
-
9
10
VDC
S:
Plug-in
T:
Quick-connect (upper bracket mounting)
7. Classification
None: General-purpose
E:
High-capacity
H:
High-sensitivity
N:
LED indicator
D:
Diode
ND: LED indicator and diode
8. Test button
I:
Test button
Note:
Applied for only SN and SND type
9. Contact Material
None: AgCdO
ASI: AgSnIn
10. Rated Coil Voltage
Refer to
Coil Ratings.
1. Relay Function
None: Single-side stable
K:
Double-winding latching.
2. Number of Poles
1:
1 pole
2:
2 poles
3. Contact Form
None:
A:
4. Contact Type
#
PDT
#
PST-NO
None: Single
Z:
Bifurcated
3:
Bifurcated crossbar
5. Enclosure Ratings
None: Flux protection
4:
Fully sealed
6. Terminals
None: Straight PCB
I
Accessories (Order Separately)
Applicable Relay model
Track/surface-mounting
Socket
Back-mounting Socket
Terminals
PCB terminals
Solder terminals
PCB terminals
Solder terminals
Model
P2R-05P, P2R-057P
P2R-05A
P2R-08P, P2R-087P
P2R-08A
Connecting Sockets
Number of poles
1 pole
G2R-1-
P2RF-05-E
S(N)(D)(ND)(NI)(NDI)G2R-13- P2RF-05
S (G2R-1A3-S)
G2R-2-S(N)(D)(ND)(NI)(NDI)
See
Dimensions
for details on socket size.
P2RF-08-E
P2RF-08
2 poles
Note:
Mounting Track
Applicable socket
Track connecting socket
Description
Mounting track
50 cm ( ) x 7.3 mm (t): PFP-50N
1 m ( ) x 7.3 mm (t): PFP-100N
1 m ( ) x 16 mm (t): PFP-100N2
8
8
8
Model
End plate
Spacer
Back connecting socket
Mounting plate
PFP-M
PFP-S
P2R-P*
*Used to mount several P2R-05A and P2R-08A connecting sockets side by side.
2
G2R
G2R
Specifications
I
Coil Ratings
12 VAC
50 Hz
60 Hz
93 mA
75 mA
65
W
Armature OFF
Armature ON
0.19
0.39
24 VAC
46.5 mA
37.5 mA
260
W
0.81
1.55
100/
(110) VAC
11 mA
9/
(10.6) mA
4,600
W
13.34
26.84
120 VAC
9.3 mA
7.5 mA
6,500
W
21
42
200/ (220)
VAC
5.5 (4.0)
mA
4.5 (5.3)
mA
20,200
(25,000)
W
51.3
102
220 VAC
5.1 mA
4.1 mA
25,000
W
57.5
117
230 VAC
240 VAC
Rated voltage
Rated current
4.7 (3.7) mA 4.7 mA
3.8 (3.1) mA 3.8 mA
26,850
(30,000)
W
62
124
30,000
W
65.5
131
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Note:
80% max. of rated voltage
30% min. of rated voltage
140% of rated voltage (at 23
C)
Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz)
1.
Rated voltage of bifurcated crossbar contact type: 100/(110) VAC, 200/(220) VAC, 230 VAC (Approx. 0.7 VA at 60 Hz)
2.
Depending on the type of Relay, some Relays do not have coil specifications. Contact your OMRON representative for more
details.
Rated voltage
Rated current (50/60 Hz)
Coil resistance
Coil inductance
(H) (ref. value)
Armature OFF
Armature ON
5 VDC
106 mA
47
W
0.20
0.39
6 VDC
88.2 mA
68
W
0.28
0.55
12 VDC
43.6 mA
275
W
1.15
2.29
24 VDC
21.8 mA
1,100
W
4.27
8.55
48 VDC
11.5 mA
4,170
W
13.86
27.71
100 VDC
5.3 mA
18,860
W
67.2
93.2
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Note:
70% max. of rated voltage
15% min. of rated voltage
170% of rated voltage (at 23
C)
Approx. 0.53 W
Rated voltage of bifurcated crossbar contact type: 12 VDC, 24 VDC
High-sensitivity Relays
Rated voltage
Rated current (50/60 Hz)
(see note 1.)
Coil resistance (see note 1.)
Coil inductance
(H) (ref. value)
Armature OFF
Armature ON
5 VDC
71.4 mA
70
W
0.37
0.75
6 VDC
60 mA
100
W
0.53
1.07
12 VDC
30 mA
400
W
2.14
4.27
24 VDC
15 mA
1,600
W
7.80
15.60
48 VDC
7.5 mA
6,400
W
31.20
62.40
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Note:
70% max. of rated voltage
15% min. of rated voltage
170% of rated voltage (at 23
C)
Approx. 0.36 W
1.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
+15%
/
–20%
(AC rated current)
or
±10%
(DC coil resistance).
2.
LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be
increased by approximately 1 mA; the VDC rated current, by approximately 4 mA.
3.
Operating characteristics are measured at a coil temperature of 23°C.
3
G2R
Double-winding Latching Relays
Rated voltage
Set coil
Rated current (see note 1.)
Coil resistance (see note 1.)
Coil inductance
(H) (ref. value)
Reset coil
Rated current
Coil resistance
Coil inductance
(H) (ref. value)
Must set voltage
Must reset voltage
Max. voltage
Power consumption
Note:
I
Armature OFF
Armature ON
Armature OFF
Armature ON
5 VDC
167 mA
30
W
0.073
0.146
119 mA
42
W
0.003
0.006
6 VDC
138 mA
43.5
W
0.104
0.208
100 mA
60
W
0.005
0.009
12 VDC
70.6 mA
170
W
0.42
0.83
50 mA
240
W
0.018
0.036
24 VDC
34.6 mA
694
W
1.74
3.43
25 mA
960
W
0.079
0.148
G2R
70% max. of rated voltage
70% max. of rated voltage
140% of rated voltage (at 23
C)
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW
1.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
2.
Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
Item
General-purpose, quick-connect terminal
1 pole
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
2 poles
Resistive load
(cos
f
= 1)
5 A at 250
VAC;
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1,875 VA,
150 W
1,250 VA,
150 W
10 mA at 5 VDC
500 VA,
90 W
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
2 A at 250 VAC;
3 A at 30 VDC
1 pole
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
High-capacity
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays
Number of poles
Load
Rated load
10 (1) A at 250 VAC; 7.5 A at 250
10 (1) A at 30 VDC VAC;
5 A at 30 VDC
10 (1) A
16 A at 250
8 A at 250 VAC;
VAC;
8 A at 30 VDC
16 A at 30 VDC
16 A
380 VAC, 125 VDC
16 A
4,000 VA,
480 W
2,000 VA,
240 W
Rated carry current
Max. switching voltage
380 VAC, 125 VDC
Max. switching current
10 (1) A
Max. switching power
Failure rate
(reference value)
Note:
2,500 (250) VA,
300 (30) W
100 mA at 5 VDC (1 mA at 5 VDC)
100 mA at 5 VDC
1.
P level:
l
60
= 0.1 x 10
–6
/operation
2.
( ): Bifurcated crossbar contact type.
PCB/Flux Protection Relays
Item
Number of poles
Load
1 pole
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Bifurcated contacts
1 pole
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
High-sensitivity
2 poles
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Rated load
Rated carry current
5 A at 250 VAC; 2 A at 250 VAC;
5 A at 30 VDC
3 A at 30 VDC
5A
5 A at 250 VAC; 2 A at 250 VAC;
5 A at 30 VDC
3 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1,250 VA,
150 W
100 mA at 5 VDC
500 VA,
90 W
3 A at 250 VAC; 1 A at 250 VAC;
3 A at 30 VDC
1.5 A at 30 VDC
3A
380 VAC, 125 VDC
3A
750 VA,
90 W
10 mA at 5 VDC
250 VA,
45 W
Max. switching voltage
380 VAC, 125 VDC
Max. switching current
5 A
Max. switching power
Failure rate
(reference value)
Note:
1,250 VA,
150 W
1 mA at 5 VDC
500 VA,
90 W
P level:
l
60
= 0.1 x 10
–6
/operation
4
G2R
PCB/Fully sealed Relays
Item
Number of poles
Load
1 pole
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
General-purpose (single contact)
2 poles
Resistive load
(cos
f
= 1)
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
1 pole
Resistive load
(cos
f
= 1)
Bifurcated contact
G2R
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Rated load
Rated carry current
8 A at 250 VAC; 6 A at 250 VAC;
8 A at 30 VDC
4 A at 30 VDC
8A
4 A at 250 VAC; 1.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC;
4 A at 30 VDC
2.5 A at 30 VDC 5 A at 30 VDC
3 A at 30 VDC
4A
380 VAC, 125 VDC
4A
1,000 VA,
120 W
10 mA at 5 VDC
375 VA,
75 W
5A
380 VAC, 125 VDC
5A
1,250 VA,
150 W
1 mA at 5 VDC
500 VA,
90 W
Max. switching voltage
380 VAC, 125 VDC
Max. switching current
8 A
Max. switching power
Failure rate
(reference value)
Note:
2,000 VA,
240 W
100 mA at 5 VDC
1,500 VA,
120 W
P level:
l
60
= 0.1 x 10
–6
/operation
Latching Relays
Number of poles
Load
1 pole
Resistive load
(cos
f
= 1)
5 A at 250 VAC;
5 A at 30 VDC
5A
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
3.5 A at 250 VAC;
2.5 A at 30 VDC
2 poles
Resistive load
(cos
f
= 1)
3 A at 250 VAC;
3 A at 30 VDC
3A
380 VAC, 125 VDC
3A
875 VA, 75 W
750 VA, 90 W
10 mA at 5 VDC
375 VA, 60 W
Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2 A at 30 VDC
Rated load
Rated carry current
Max. switching voltage
380 VAC, 125 VDC
Max. switching current
5 A
Max. switching power
Failure rate
(reference value)
Note:
I
1,250 VA, 150 W
100 mA at 5 VDC
P level:
l
60
= 0.1 x 10
-6
/operation
Characteristics
Item
1 pole
30 m
W
max. (high-capacity type: 100 m
W
max.)
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
1,000 M
W
min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
50 m
W
max.
2 poles
Standard Relays
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
2
Malfunction: 200 m/s
2
when energized; 100m/s
2
when no energized
Mechanical: AC coil: 10,000,000 operations min.;
DC coil:
20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Operating:
-
40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g (plug-in terminal: approx. 20 g)
Ambient temperature
Ambient humidity
Weight
Note:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.