EEWORLDEEWORLDEEWORLD

Part Number

Search

ERCD-010-10.00-TEU-TED-3-L

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size834KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

ERCD-010-10.00-TEU-TED-3-L Overview

Interconnection Device, ROHS COMPLIANT

ERCD-010-10.00-TEU-TED-3-L Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
F-211-1
(0,80mm) .0315"
ERCD SERIES
ERCD–050–08.00–SBR–STR–1–D
ERCD–020–10.00–TEU–STR–1–R
EDGE RATE COAX CABLE ASSEMBLIES
SPECIFICATIONS
i
For complete specifications and
recommended PCB layouts see
www.samtec.com?ERCD
Cable:
34 AWG coax ribbon cable
Signal Routing:
50Ω Single-Ended
Plating:
Au over 50µ" (1,27µm) Ni
Operating Temp Range:
-25°C to +105°C
RoHS Compliant:
Yes
Mates with:
ERF8, ERM8
Broadside wiping
contacts reduce
unwanted
crosstalk
Cable
Length
6" (152,4mm)
Rated @ 7dB
Insertion Loss
ERCD
34 AWG
micro ribbon
coax cable
6.37 GHz / 12.74 Gbps
39.37" (1m)
2.19 GHz / 4.38 Gbps
Performance data for other cable lengths
and complete test data available at
www.samtec.com?ERCD or contact
sig@samtec.com
(0,80mm)
.0315" pitch
Rugged metal
latching system
Patent Pending
ERCD
NO. POSITIONS
PER ROW
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
LATCH
END TO END
DV to DV
DV to Edge Mount (-TEX)
Edge Mount (-TEX)
POSITIONS
PER ROW
–010
–020
–030
–040
–050
–060
B
(23,47)
.924
(26,69)
1.051
(29,92)
1.178
–010, –020, –030,
–040, –050, –060
OAL = Wire Length +
B
02
01
–“XX.XX”
= Wire Length
in Inches
(95,3mm) 03.75"
minimum
–TTR
= Terminal, Top Right
–1
= Pin 1 to
Pin 1
Latch is
required
–TTL
= Terminal, Top Left
–2
= Pin 1 to
Pin 2
–L
= End No. 1
Standard Latch,
End No. 2
Squeeze Latch
(TEX only)
–TBR
02
= Terminal, Bottom Right
01
–3
= Pin 1 to
Pin N -1
–TBL
= Terminal, Bottom Left
A
(22,66) .892
(30,66) 1.207
(38,66) 1.522
(46,66) 1.837
(54,66) 2.152
(62,66) 2.467
–4
= Pin 1 to
Pin N
–R
= End No. 1
Squeeze Latch
(TEX only),
End No. 2
Standard Latch
–STR
= Socket, Top Right
A
–STL
= Socket, Top Left
–D
= Both Ends
Standard
Latch
Note:
Cable lengths longer than
40.00" (1 meter) are not
supported with S.I. test data.
–SBR
= Socket, Bottom Right
(18,75)
.738
–SBL
= Socket, Bottom Left
–N
= No Caps
(Both ends have
Latch option)
Note:
Verify part number and correct
wiring scheme with Samtec’s
Interactive Cable Builder at
www.samtec.com/cable_
builder/pitch.aspx
Note:
Some lengths, styles and
options are non-standard,
non-returnable.
–TEU
(10,15)
.400 (7,72)
.304
(13,76)
.542
= Terminal,
Edge Mount Up
–TED
END NO.1
(–STL SHOWN)
END NO.2
(–TTR SHOWN)
= Terminal,
Edge Mount Down
= Both ends
have Squeeze
Latch
(TEX only)
–B
WWW.SAMTEC.COM
[Lazy self-care fish tank control system] APP control pins in non-RTE mode of KEIL environment
[Lazy self-care fish tank control system] APP control pins in non-RTE mode of KEIL environment 1. Import routines under KEIL 1. The software and ON official SDK have been installed 2. Import routinesS...
蓝雨夜 onsemi and Avnet IoT Innovation Design Competition
POE power supply problem
I found a few articles about POE power supply on the Internet, but I was confused after reading them. I have a few questions to ask the experts The standard mentions that the POE management device PSE...
bigbat Power technology
Writing Verilog Code for AD Sampling FPGA Program
Provide a section of AD sampling FPGA programThe program is as followsVerilog source program is as follows://--------------------------------------------------------------------------- //-- File name:...
Aguilera Microcontroller MCU
capacitance
How to get out of the area of "the calculation formula of capacitors with DC isolation, AC passing and capacitive reactance", I found that I am still at this stage. I don't know how to analyze the cap...
aq1261101415 Analog electronics
The basic principles and methods of SRIO error handling
SRIO error detection is mainly divided into two parts, physical layer error detection, logical layer / transport layer error detection, each error detection has a specific register to control. Physica...
fish001 Microcontroller MCU
#idlemarket# Puyuan programmable linear power supply + NETGEAR Gigabit intelligent network management switch
[i=s]This post was last edited by qq849682862 on 2021-9-6 20:04[/i]Brand new RIGOL DC power supply, DP832 (three channels), all options are on, equivalent to the monochrome version DP832A ! You can al...
qq849682862 Buy&Sell

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号