10 Watts
AEE01-12Vin
Total Power:
Input Voltages:
No. of Outputs:
10 Watts
12V
Single and Dual
Electrical Specs
Input
Input range
Efficiency
9 to 18 VDC
78% typical (3.3V)
Output
Voltage tolerance
Overall regulation
Noise/ripple
Transient response
±1.0%
±1% max
1% Typ, 2% Max
300 usec typical (50% step load
change to within 3%Vo)
±0.02 %Vo/°C
330kHz
Temperature Regulation
Special Features
•
•
•
•
•
•
•
10 W, Dual output
2:1 Input range
1.0" x 2.0" x 0.33 case
Industry standard package
Low Profile
Low Cost
Trim and Enable Option on single out
module only
Switching frequency
Isolation
I/O isolation
1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
300 Mohms
Isolation Resistance
Environmental
Operating base temperature range:
-25°C to +100°C
Storage temperature: -40°C to +125°C
MTBF: 3 Million Hours (Belcore TR332)
Safety
UL
CSA
TUV
UL1950 Recognition
CSA22.2-950 Recognition
EN60950 Recognition
24
America’s (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
AEE01-12Vin
Ordering Information
Input
Voltage
9-18 V
9-18 V
9-18 V
9-18 V
9-18 V
9-18 V
9-18 V
Output
Voltage
Efficiency
78%
81%
83%
84%
81%
83%
84%
Model Number
AEE02F12
AEE02A12
AEE01B12
AEE01C12
AEE01AA12
AEE00BB12
AEE00CC12
3.3V
@
2.55 A
5.0V
@
2 A
12V
@
0.84 A
15V
@
0.68 A
±5V
@
±
1.0 A
±12V
@
±
0.42 A
±15V
@
±
0.33 A
NOTES:
Enable Function
"1" = negative logic enable (std, without "1 or 4" = no enable)
"4" = positive logic enable (std, without "1 or 4" = no enable)
Trim Feature
"9" = Trim feature (std, without "9" no Trim) Available on Single Output devices only
Notes:
1. 20 MHz bandwidth. An external 0.1 uf ceramic capacitor
is recommended to be placed from +V out to comm.
2. All specifications are typical at nominal line, full load,
and 25°C unless otherwise noted.
3. All specifications subject to change without notice.
4. Mechanical drawings are for reference only.
www.astec.com
25