EEWORLDEEWORLDEEWORLD

Part Number

Search

KPT01F20-24SY

Description
MIL Series Connector, 24 Contact(s), Aluminum Alloy, Female, Solder Terminal, Plug
CategoryThe connector    The connector   
File Size159KB,1 Pages
ManufacturerITT
Websitehttp://www.ittcannon.com/
Download Datasheet Parametric View All

KPT01F20-24SY Overview

MIL Series Connector, 24 Contact(s), Aluminum Alloy, Female, Solder Terminal, Plug

KPT01F20-24SY Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerITT
Reach Compliance Codecompliant
Other featuresSTANDARD: MIL-C-26482, POLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD
Contact completed and terminatedGold (Au)
Contact point genderFEMALE
Contact materialCOPPER ALLOY
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Environmental characteristicsMOISTURE RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceCHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size20
Termination typeSOLDER
Total number of contacts24
Base Number Matches1
KPT/KPSE
Cable connecting plugs
KPT01/MS3111 KPSE01/MS3121
Miniature circular connectors
Solder
KPT01/MS3111
Without termination assembly
KPT/KPSE
ØA
+0,03 -0,13
12,00
15,00
19,05
22,23
25,40
28,58
31,75
34,93
38,10
Crimp
KPSE01/MS3121
Shell
size*
x
8
10
12
14
16
18
20
22
24
K
±0,25
13,5
13,5
13,5
13,5
13,5
13,5
16,5
16,5
17,5
L
max.
21,5
21,5
21,5
21,5
21,5
21,5
26,8
26,8
26,8
M
±0,15
11,6
11,6
11,6
11,6
11,6
11,6
14,25
14,25
15,1
Q
Thread Type 2A
7/16-28UNEF
9/16-24UNEF
11/16-24UNEF
13/16-20UNEF
15/16-20UNEF
1- 1/16-18UNEF
1- 3/16-18UNEF
1- 5/16-18UNEF
1- 7/16-18UNEF
S
max.
20,6
23,8
26,15
28,5
30,7
33,3
36,5
39,6
42,8
ØY
max.
23,8
26,9
29,3
31,7
34,1
36,5
39,6
42,8
46,0
KPT
Z
max.
12,3
12,3
12,3
12,3
12,3
12,3
10,8
10,8
10,0
With termination assemblies
Type A
Typ A
B
A
max.
15,0
18,2
21,2
24,6
27,7
30,9
33,9
37,1
40,3
Type B or F
Type B and F
B
BF
max.
14,0
17,2
20,4
23,6
26,7
29,5
32,7
35,9
39,0
Type E
Mod. DN or F 185
Shell
size*
x
8
10
12
14
16
18
20
22
24
D
A
min.
8,5
11,8
15,0
17,9
21,1
24,1
26,5
30,4
32,8
Type E
B
E
max.
14,2
17,2
20,4
23,4
26,6
29,6
32,8
36,0
39,2
L
A
max.
38,0
38,0
38,0
38,0
38,0
38,0
43,1
43,1
43,1
V
Thread Type 2A
1/2-28UNEF
5/8-24UNEF
3/4-20UNEF
7/8-20UNEF
1 -20UNEF
1-3/16-18UNEF
1-3/16-18UNEF
1-7/16-18UNEF
1-7/16-18UNEF
C
Thread
6-32
6-32
6-32
6-32
6-32
8-32
8-32
8-32
8-32
D
BF
min.
6,0
7,5
10,7
13,9
15,5
19,6
19,6
23,6
25,2
G
BF
min.
2,9
4,5
7,7
9,3
12,4
15,6
15,6
18,8
20,1
H
BF
max.
19,3
20,8
24,4
27,2
28,7
35,3
35,3
39,9
43,2
L
BF
max.
46,0
46,0
46,0
46,0
49,0
49,0
51,1
51,1
51,1
Shell
size*
x
8
10
12
14
16
18
20
22
24
L
E
max.
32,5
32,5
32,5
32,5
32,5
32,5
34,5
34,5
34,5
x
Mod. DN or F 185
D2
-0,5
15,6
18,4
23,7
24,5
29,8
32,0
36,1
38,5
41,6
L1
max.
35,0
35,0
35,0
35,0
37,0
37,0
42,0
42,0
42,0
L2
±0,5
12,2
12,2
12,2
12,2
14,5
14,5
15,8
15,8
14,9
* See page 5, 7 and 8 for ordering number information
in series KPSE only contact arrangements 8-3A and 8-33 available
14
Subject to change
How to choose the appropriate inductor and its parameters? | MPS invites you to learn practical tips and win gifts by commenting!
In Buck circuit, the design of inductor is a key point, which is closely related to the efficiency, output ripple voltage and loop stability of the system. Let's discuss with MPS: how to choose the ap...
EEWORLD社区 Power technology
I need help with soldering tips. Why does flux often splash out when I add tin to my soldering iron, burning my hands?
Hey guys, why does the flux often splash out when I add tin to my soldering iron and burn my hands? Soldering Tips for Help...
Knight97538 Power technology
What are the differences between RTU and DTU?
1. Name:RTU: The full name of RTU is Remote Terminal Unit, which is responsible for monitoring and controlling field signals and industrial equipment.DTU: The full name of DTU is Data Transfer Unit. I...
蓝先生 Industrial Control Electronics
Three key technologies of mobile robots
There are many issues to be studied in the field of robotics, involving multiple disciplines such as computers, sensors, human-computer interaction, and biosecurity. Among them, environmental percepti...
eastin8 Mobile and portable
FPGA implementation of terrestrial digital television symbol and carrier synchronization.pdf
FPGA implementation of terrestrial digital television symbol and carrier synchronization.pdf...
zxopenljx EE_FPGA Learning Park
Classic: MSP430 microcontroller enters low power mode program code
[size=4]Method to enter low power consumption: [/size] [size=4]#include "msp430x42x.h" [/size] [size=4]void main( void ) [/size] [size=4]{ [/size] [size=4] WDTCTL=WDTPW+WDTHOLD; //Stop watchdog [/size...
fish001 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号