VE-231-EU-BM-F4

Description
DC-DC Current Source Module, 1 Output, Hybrid, PACKAGE-9
CategoryPower/power management    The power supply circuit   
File Size234KB,3 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Environmental Compliance  
Download Datasheet Parametric View All

VE-231-EU-BM-F4 Overview

DC-DC Current Source Module, 1 Output, Hybrid, PACKAGE-9

VE-231-EU-BM-F4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Parts packaging codeMODULE
package instruction,
Contacts9
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC CURRENT SOURCE MODULE
Maximum input voltage60 V
Minimum input voltage42 V
Nominal input voltage48 V
JESD-30 codeR-XUFM-P9
JESD-609 codee3
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature85 °C
Minimum operating temperature-10 °C
Maximum output voltage13.2 V
Minimum output voltage9 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceMATTE TIN OVER NICKEL
Terminal formPIN/PEG
Terminal locationUPPER
Maximum time at peak reflow temperatureNOT SPECIFIED
Fine-tuning/adjustable outputYES
Base Number Matches1
Data Sheet
BatMod
TM
Battery Charger Current Source Modules
Features
RoHS compliant (VE versions)
Programmable output current
Booster versions available
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7 mm)
UL, CSA, TÜV
Compatible with all major battery types
Inputs: 48, 150, 300 Vdc
Outputs: 12, 24, 48 Vdc Nominal
Analog current monitor
Analog overvoltage adjust
CE Marked
Product Highlights
The BatMod combines Vicor’s industry standard
package with the flexibility of a power converter
whose output voltage and output current may be
independently set. BatMod’s allow the user to
independently program a constant output current
and a maximum float voltage. The float voltage is
the point at which the BatMod transitions from
constant current to constant voltage. These
features make the BatMod an ideal candidate for
battery charging and other applications which
require a controlled current source.
The BatMod is also available in booster
versions that enable the designer to create systems
capable of multiple kilowatts of
output power.
With its wide range of input options, the BatMod
is compatible with all major
battery types. This new current output
module finds application in systems where easily
programmable current is of primary importance.
Consult factory for availability of input/output volt-
age ranges not shown.
Packaging Options
SlimMods™, high power density, flangeless
packages and FinMods™, featuring integral
finned heatsinks.
SlimMod:
Option suffix:
- S
Example:
VX - XXX - XU - BM
- S
FinMod:
Option suffix:
- F1, - F2, - F3
and
- F4
Examples:
VX - XXX - XU -BM -F1, 0.25"H longitudinal fin
VX - XXX - XU -BM -F2, 0.5"H longitudinal fin
VX - XXX - XU -BM -F3, 0.25"H transverse fin
VX - XXX - XU -BM -F4, 0.5"H transverse
fin
Specifications
(typical TBP = 25°C, nominal line, 75% load, unless otherwise specified)
Parameter
Nominal input voltage
Output current
(Refer to safe operating curves on page 2)
Rating
48 Vdc, 150 Vdc,
300 Vdc
0 – 14.5 A
0 – 7.25 A
0 – 3.6 A
1–5V
1–5V
0 – 2.5 V
15 V, 30 V, 60 V +/-1%
V-Mode: 300 µsec typ.
I-Mode: 250 µsec typ.
3,000 V
RMS
500 V
RMS
1,500 V
RMS
Notes
42 – 60 V, 100 – 200 V,
200 – 400 V
12 V battery system
24 V battery system
48 V battery system
Zero to max. current
Zero to full load
Zero to FS output
12 V, 24 V, 48 V
Output Respectively
V
NOM
for 50 – 100%
load changes
Current control input
Current monitor output
Voltage control input
Output voltage setpoint
Trimmable +10%, -25%
Dynamic characteristics
Dielectric withstand
Input to output
Output to baseplate
Input to baseplate
Part Numbering
(typical model: input 300 Vdc, output 12 Vdc at 200 W)
V
I
*
-
2 6 1
-
E U
-
B M
*
E
= RoHS
Module
2
= Driver
B=
Booster
Input Voltage
Nominal
Range
3
= 48 V 42 – 60 V
5
= 150 V 100 – 200 V
6
= 300 V 200 – 400 V
Output Voltage
Nominal
Range
1
= 12 V
11.25 – 16.5 V
3
= 24 V
1
22.5 – 33.0 V
4
= 48 V
45.0 – 66.0 V
1
Product Grade Temperatures (°C)
Grade Operating
Storage
E
=
-
10 to + 85
-
20 to + 100
C
=
-
25 to + 85
-
40 to + 100
I
=
-
40 to + 85
-
55 to + 100
M
=
-
55 to + 85
-
65 to + 100
Available in 300 V input only
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
BatMod Battery Charger Current Source Modules
Rev. 1.5
Page 1 of 3
Set your site on VICOR at www.vicorpower.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号