-All of the VWRAS1-SMT Series have been tested according to the following recommended testing circuit before leaving the factory.
This series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1).
Vout
±5 V
Table 1
±9 V
±12 V
±15 V
±24 V
1.
Cout/μF (max)
±330
±220
±100
±47
±22
CTRL Terminal
When open or high impedance, the converter will work well; When this pin is ‘high’; the converter will shutdown; It should be noted
that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter.
Input current
While using the unstable power source, please ensure the output voltage and ripple voltage do not exceed indexes of the converter.
The preceding power source must be able to provide for converter sufficient starting current lp. (Figure 1)
Figure 1
No parallel connection or plug and play.
D
IS
C
cui.com
O
N
TI
Ip
Input Voltage
Range
Input Current(A)
Input Voltage (V)
N
U
ED
For more information, please visit the
product page.
CUI Inc
│
SERIES:
VWRAS1-SIP
│
DESCRIPTION:
DC-DC CONVERTER
date
09/07/2012
│
page
5 of 5
REVISION HISTORY
rev.
1.0
1.02
1.03
description
initial release
new template applied, V-Infinity branding removed, VWRAS1-D48-D5-
SIP and VWRAS1-D48-D12-SIP discontinued
date
picture updated
The revision history provided is for informational purposes only and is believed to be accurate.
D
IS
C
O
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to