Description
Power Transformer, 2VA
CategoryPower management    transformer   
File Size767KB,3 Pages
ManufacturerAvel Lindberg
Download Datasheet Parametric View All

OB2-9 Overview

Power Transformer, 2VA

OB2-9 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPCB MOUNTABLE
CertificationUL; CSA; VDE; IEC
Center click function 1NO
Center click function 2NO
high17.6 mm
length53 mm
Manufacturer's serial numberOB
Installation featuresCHASSIS MOUNT
Number of secondary windings2
Output current 10.11 A
Output voltage 19 V
physical size53mm X 44mm X 17.6mm
main ratingDUAL 115V
surface mountNO
Transformer typePOWER TRANSFORMER
VA rating2 VA
width44 mm
Base Number Matches1
Power Transformers
Low-Profile Encapsulated
T
HE
P
OWER
P
ROFESSIONALS
The International On-Board Transformer
OB Range transformers are mounted in resin-filled, flat
thermoplastic cases with pins for soldering directly to
plated-through holes in P.C. boards.
For additional mounting strength, four holes are
molded into the corners of the case to accept optional
mounting screws.
The non-concentric twin primary and secondary
windings are wound on separate bobbins, which
provides maximum isolation and low inter-winding
capacitance.
The low height profile allows for close spacing
between boards.
Features and Benefits
International certifications: UL 506, CSA C22.2,
EN 60/742, EN 61 558, SEV 1003, VDE 0551,
VDE 0570. CE marked.
Also available in self-extinguishing materials
to UL 94V-0.
Low profile
PCB mounted
Resin filled under vacuum
5KV AC flash test
Custom designs available
Industry standard
High reliability
General Specification for OB types
Primaries:
115/230 V.
Frequency:
50/60 Hz.
Maximum ambient temperature:
40˚ C.
Secondary voltage tolerance:
Within 5% at normal input
and full load.
Flash tested:
at 5K VAC.
Mounting:
On P.C. board.
Certifications:
VDE 0551, VDE 0570, IEC 742, UL 506,
DIN/EN60 742, EN61 558, CSA C22.2, SEV 1003;
EN 60-950 available on request.
Transformer Connections
Primaries and Secondaries
Parallel Connected
2xI
V
230V
C.T. 2 x V
230V
Primaries and Secondaries
Series Connected
I
Primaries Series Connected,
Secondaries Independent
I
V
I
V
0
115V
page
14
860/355-4711 • FAX 860/354-8597
www.avellindberg.com • sales @avellindberg.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号