BCD Series
Optical blood component detectors
FEATURES
· Non-invasive optical technology
· Micro-controller based integral
circuitry
· Immunity to ambient light
· High accuracy and reliability
· Detects blood per ANSI/AAMI
RD5:2003
SPECIFICATIONS
Maximum ratings
Supply voltage (V
S
)
Supply current
Temperature limits
Storage
Operating
Humidity limits
5 V
DC
(optional 6...24 V
DC
)
typ. 150 mA
ELECTRICAL CONNECTION
-20 ... 85 °C
5 ... 60 °C
0 - 95 %RH
(non-condensing)
Sensor
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Brown
Red
Orange
Yellow
Green
Blue
Violet
Gray
White
Return
Power in
CAL input
CAL output
Blood output
Tube detect output
Liquid detect output
NC
NC
NC
Red intensity analog output
Blue intensity analog output
NC
NC
Note: Set CAL input (Pin 3) momentary high
to begin calibration. CAL output (Pin 4)
will be high if calibration is complete.
November 2007 / 307
1/3
www.sensortechnics.com
BCD Series
Optical blood component detectors
PERFORMANCE CHARACTERISTICS
Characteristics
Logic low voltage
Logic high voltage
CAL input min. width
1
Response time
Calibration
2
Blood detect
3
Tube detect
Liquid detect
100
200
V
S
-0.7
50
15
500
ms
Min.
Typ.
Max.
0.6
Units
V
ms
s
Notes:
1. The minimum width for the CAL input to initiate a calibration cycle. Pulses shorter than this may be ignored
2. The maximum time to perform the tube calibration cycle.
3. The maximum time to detect blood levels rising above the limit or blood levels falling below the limit.
OUTLINE DRAWING
0.42
(10.67)
Slot for 0.250 (6.35) tube
1.25
(31.75)
1.50
(38.10)
0.75
(19.05)
Threaded holes
4-40 x 0.22 (5.59)
1.25
(31.75)
1.00
(25.40)
Connector Molex 51021-1400
all dimensions in inches (mm)
November 2007 / 307
2/3
www.sensortechnics.com
BCD Series
Optical blood component detectors
ORDERING INFORMATION
Series
Options
BCD
Electrical
1
5 V input,
logic output
2
3
6...24 V input,
logic output
5 V input,
analog and
logic output
6...24 V input,
analog and
logic output
Options
000
Standard
(threshold AAMI),
28 inch leads,
no tube detection,
no liquid detection
8
9
Design type
for rigid tubing
for soft tubing
Tubing siz e
04
1/4 inch O.D.
4
Example:
BCD -
1
000
-
8
04
Notes:
Sensortechnics is asking customers for a sample of their tubing. The sensor will then be
calibrated for exactly this tubing. For proper function the sensor should only be used
with the tubing which was sent to Sensortechnics!
Custom specific modifications are widely available. Please contact your nearest
Sensortechnics sales office for further information.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
November 2007 / 307
3/3
www.sensortechnics.com